41
Manufactured for: General Electric Company, Louisville, KY 40225 1.800.626.2002
Performance Data Sheet
SmartWater Filtration System
MSWF Cartridge
This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.*
(100% safety factors built in for unmetered usage)
Standard No. 42: Aesthetic Effects
USEPA
Influent
Effluent
% Reduction
Min. Required
Parameter
MCL
Challenge Concentration
Average
Maximum
Average
Minimum
Reduction
Chlorine
—
2.0 mg/L + 10%
0.06 mg/L
0.10 mg/L
97%
95.1%
≥ 50%
Particulate**
—
at least 10,000 particles/mL
408,333
670,000
95.5%
89.4%
≥ 85%
Standard No. 53: Health Effects
Max. Permissible
Product Water
USEPA
Influent
Effluent
% Reduction
Concentration
Parameter
MCL
Challenge Concentration
Average
Maximum
Average
Minimum
mg/L
Turbidity
1 NTU***
11 + 1 NTU***
0.38 NTU
0.5 NTU
96.5%
95.4%
0.5 NTU
Cysts
99.95% Reduction
Minimum 50,000 L
< 1 #/L
4 #/L
> 99.99%
> 99.99%
99.95%
Lead at pH 6.5
0.010 mg/L
0.15 mg/L + 10%
< 1 ppb
< 1 ppb
99.3%
99.3%
0.010 mg/L
Lead at pH 8.5
0.010 mg/L
0.15 mg/L + 10%
3.1 ppb
9.0 ppb
98.0%
95.5%
0.010 mg/L
Mercury at pH 6.5
0.002 mg/L
0.006 mg/L + 10%
0.34 ppb
0.7 ppb
94.0%
89.6%
0.002 mg/L
Mercury at pH 8.5
0.002 mg/L
0.006 mg/L + 10%
0.66 ppb
1.5 ppb
88.4%
73.7%
0.002 mg/L
Lindane
0.0002 mg/L
0.002 mg/L + 10%
< 0.02 ppb
< 0.02 ppb
> 99.0%
> 99.0%
0.0002 mg/L
Atrazine
0.003 mg/L
0.009 mg/L + 10%
< 0.5 ppb
< 0.5 ppb
> 93.9%
> 94.3%
0.003 mg/L
2,4-D
0.070 mg/L
0.210 mg/L + 10%
7.7 ppb
35 ppb
96.0%
82.0%
0.070 mg/L
Toxaphene
0.003 mg/L
0.015 mg/L + 10%
< 1 ppb
< 1 ppb
> 92.9%
> 92.9%
0.003 mg/L
Benzene
0.005 mg/L
0.015 mg/L + 10%
< 0.5 ppb
< 0.5 ppb
> 96.8%
> 97.0%
0.005 mg/L
Carbofuran
0.040 mg/L
0.080 mg/L + 10%
< 1 ppb
< 1 ppb
> 98.7%
> 98.7%
0.04 mg/L
P- Dichlorobenzene
0.075 mg/L
0.225 mg/L + 10%
< 0.5 ppb
< 0.5 ppb
> 99.7%
> 99.8%
0.075 mg/L
Asbestos
99% Reduction
10
7
to 10
8
fibers/L; fibers > 10µm in length
< 0.17 MF/L
< 0.17 MF/L
> 99%
> 99%
99%
* Tested using pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 2.5°C)
** Measurement in Particles/ml. Particles used were 0.5-1 microns
*** NTU=Nephelometric Turbidity Units
Operating Specifications
Capacity: certified for up to 300 gallons (1135 l); up to six months for models without a replacement filter indicator light;
up to one year for models with a replacement filter indicator light
Pressure requirement: 20–120 psi (1.4–8.2 bar), non-shock
Temperature: 33–100ºF (0.6–38ºC)
Flow rate: 0.9 gpm (3.4 lpm)
General Installation/Operation/Maintenance Requirements
Flush new cartridge at full flow for 5 minutes to purge out trapped air.
Replace cartridge when flow becomes too slow.
Special Notices
Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
This drinking water system must be maintained according to manufacturer’s instructions, including replacement of filter cartridges.
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or
after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.
Check for compliance with the state and local laws and regulations.
Note that while the testing was performed under standard laboratory conditions, actual performance may vary. Systems must be
installed and operated in accordance with manufacturer’s recommended procedures and guidelines.
NSF
®
System Tested and Certified by NSF International against NSF/ANSI Standard 42 & 53 for the reduction of:
Standard No. 42: Aesthetic Effects
Chemical Unit
Taste and Odor Reduction
Chlorine Reduction
Mechanical Filtration Unit
Nominal Particulate Reduction, Class I
Standard No. 53: Health Effects
Chemical Unit
Lead, Mercury and Atrazine Reduction
Lindane, Toxaphene and 2,4-D Reduction
Benzene, Carbofuran and
P-Dichlorobenzene Reduction
Mechanical Filtration Unit
Turbidity Reduction, Cyst Reduction,
Asbestos Reduction
Содержание PSHF6RGXCC - Profile 26' Dispenser Refrirator
Страница 86: ...Soutien au consommateur Conseils de dépannage Fonctionnement Mesures de sécurité Installation 86 Notes ...
Страница 129: ...Servicio al consumidor Solucionar problemas Operación Seguridad Instalación 129 Notas ge com ...
Страница 130: ...130 Notas Solucionar problemas Servicio al consumidor Operación Seguridad Instalación ...