background image

8

Program Menu

To edit the time and temperature settings for any day of the week:

1.  Select and enter the Program Menu 

and the screen to the right will appear.

2.  Press PREV or NEXT to scroll through 

the settings and press UP or DOWN to 

change a setting.

3.  Press MENU to confirm and return to 

the previous screen.

MORN 

       

FVF      

       

NIGHT

 

       

TUESDAY

 

:

 

       

:

 

       

:

 

       

10:00P     

       

HEATCOOL 

       

DAY 

       

:

 

       

INFO - - >  Copy Or Reset 

       

  6:00P     

       

  8:00A     

       

  6:00A     

       

  70    

       

  70    

       

  65    

       

  65    

       

  85    

       

  75    

       

  75    

       

  78    

       

To copy or reset a program:

1.  Select and enter the Program Menu.

2.  Press INFO while displaying the screen 

you wish to copy and the screen to the 

right appears.

3.  Use PREV or NEXT to select ‘Copy 

Program’ or ‘Reset program’ and press 

SELECT to confirm. 

  If you selected ‘Copy Program’, you will see a square next to the day 

you wish to copy.  Use the UP and DOWN buttons to select a the day 

that you wish to copy the program to and want the program settings 

to be copied to and press SYS until the ‘N’ changes to a ‘Y’.   This can be 

done for multiple days.  Then press SELECT and ‘Successfully Copied’ 

displays.

  If you selected ‘Reset program’, ‘Are you sure you want to RESET the 

program?’ appears. Press SELECT to confirm or MENU to exit and return 

to the previous screen. When you reset the program, all the Program 
menu settings return to the factory default settings.

Copy Program 

       

Reset Program

 

       

Copy & Reset

 

Содержание PROGRAMMABLE THERMOSTAT

Страница 1: ...49 50276 03 11 GE PROGRAMMABLE THERMOSTAT Operating Instructions and Limited Warranty ...

Страница 2: ...ode 5 Main Menu Settings 6 Override Menu 6 Program Menu 8 Setup Menu 9 Networking Menu 10 Query Menu 11 Info Screen 12 Indicators 14 Reset 14 FCC Declaration 15 ETL 16 Specifications 17 Warranty 18 Appendix 20 Terminal definitions 20 Wiring Diagram for Heat Pump 21 Wiring Diagram for Conventional 22 ...

Страница 3: ... for its intended purpose as described in this Owner s Manual If this is a new installation locate the thermostat 4 to 5 feet above the floor in accordance with applicable building codes Install the device in a location that provides good airflow characteristics and avoid areas behind doors near corners air vents direct sunlight or heat generating devices Installation in these areas could impact t...

Страница 4: ...urrent menu settings and return previous menu screen Select Enter sub menu Confirm current menu setting which include but not limited to below functions Temporary or permanent override of Demand Response events Scan Join exit Zigbee network Get current utilty price and message Confirm message or confirm cancel message Info Provides information which includes but is not limited to Demand response e...

Страница 5: ... importance THU APR 15 4 30A HEAT FAN AUTO NIGHT F 62 80 Event 4 Message 3 SET HEAT COOL MODE 1 When you are in the HOME SCREEN press PREV and the screen opposite appears 2 Press UP or DOWN to select one of the following options Heat Cool or Off Conventional HAVC Heat Emer Emergency Heating Cool or Off Heat Pump HVAC 3 Press MENU or wait 5 seconds to confirm your selection and return to the Home S...

Страница 6: ...CATION OVERRIDE To accept events 1 Select and enter the Override Menu 2 Press PREV or NEXT to select Accept Current Event or Accept All Events 3 Press SELECT to confirm NOTE The unit will automatically accept events unless you have set it to reject events and vice versa REJECT CURRENT EVENT REJECT ALL EVENTS VACATION OVERRIDE To reject events 1 Select and enter the Override Menu 2 Press PREV or NE...

Страница 7: ... your utility company can override your temperature setting when the new event setting saves energy for example a In wintertime when the outdoor temperature is cold you may set your vacation temperature to 50 F to prevent pipes from freezing However if the utility company sends an event to reduce the temperature to 45 F to save energy it will override your vacation temperature and make the new Hea...

Страница 8: ...creen to the right appears 3 Use PREV or NEXT to select Copy Program or Reset program and press SELECT to confirm If you selected Copy Program you will see a square next to the day you wish to copy Use the UP and DOWN buttons to select a the day that you wish to copy the program to and want the program settings to be copied to and press SYS until the N changes to a Y This can be done for multiple ...

Страница 9: ...en Time Source Changes the time source to either user setting or util ity setting If the Network setting is selected press Info to obtain the network time It will be reflected on the Home Screen Time Changes the time Only visible if Time Source is set to Setting Date Changes the time Only visible if Time Source is set to Setting Setup Menu To edit the Setup menu 1 Select and enter the Setup Menu a...

Страница 10: ...e Joined screen appears It may take up to a minute for the connection process to complete 6 If All was selected the thermostat will scan all available networks and return a list Use UP or DOWN to select a network Press SELECT to join Upon a successful network join the Joined screen appears It may take up to a minute for the connection process to complete 7 If Channel was selected use UP or DOWN to...

Страница 11: ...ou select this option your request to be notified of the current price options will automatically be sent out Get schedule price Follow the same steps as Get event to automatically send out your request for the schedule price Get last message When you select this option your request to be notified of your last message received will automatically be sent out Note If Please join network first appear...

Страница 12: ...will happen at the START TIME Active This event is currently in progress Rejected You have rejected this event LEVEL There are 9 different event levels Green Energy Saving Levels 1 5 Level of message importance 1 is low and 5 is high Emergency Planned Outage Service Disconnect START TIME The event will start at this time i e 8am DURATION This event will last for this amount of time i e 2 hours EVE...

Страница 13: ...RT CHANNEL 16 SHORT 0X05D9 PAN 0x3333 1 2 MESSAGE Your request has been rejected 2 4 Confirm CHANNEL Write down your channel number and put it in a safe place It may be useful if you need to reconnect to the network SHORT PAN EPAN EUI64 FIRM HVAC if you phone for support you may be asked to provide these codes 2 When viewing any of these screens look in the top right hand corner to see how many pa...

Страница 14: ...rn it to the factory default settings INDICATORS There are two LEDs located in the top left corner of the front of the thermostat See the table below for a description of what the lights mean Yellow LED indicates the status of the HVAC system Tri color red green and orange LED indicates the status of the information from your utility company Off HVAC system is working normally Flashing HVAC system...

Страница 15: ...not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interf...

Страница 16: ... 32 113 F 0 45 C Indoor Temperature Measurement Range 40 99 F 5 37 C RF Frequency 2 40 2 48 GHz RF Range Up to 1300 ft 400 m line of sight A C Adapter Input 18 30 V AC at R and C terminals Size 5 4 L x 4 2 W x 1 H 13 6 L x 10 6 W x 2 6 H cm Weight 0 76 lb 345 g ...

Страница 17: ...17 Notes ...

Страница 18: ...inal purchase invoice or receipt to verify your warranty ii your name address and telephone number iii the Return Materials Authorization RMA number You are responsible for properly packaging and shipping the Hardware product at your cost and risk In addition to the foregoing Hardware product warranty for a period of ninety 90 days from the date of original retail purchase GE shall also provide te...

Страница 19: ...uses described by GE f damage caused by service including upgrades and expansions not performed by GE a GE authorized service provider or an authorized representative of GE g a product or part that has been modified to alter functionality or capability without the written permission of GE h defects caused by normal wear and tear or otherwise due to the normal aging of the product i removed or defa...

Страница 20: ... Common for control ciruit and thermo stat power input G FAN Y 1st stage cooling 1st stage compressor Y2 2nd stage cooling 2nd stage compressor W 1st stage heating Auxiliary heating W2 E 2nd stage heating Emergency heating W3 O B 3rd stage heating Changeover Valve RH 24VAC Power supply for Heating side RC 24VAC Power supply for Cooling side ...

Страница 21: ...r Valve Aux Hea ng Emergency Emergency relay Auxiliary hea ng relay 1st Compressor Relay 2nd Compressor Relay Fan relay AC_ IN Power Supply AC_ IN MCU 1st Compressor 2nd Compressor Jumper Wire FAN FAULT DETECT Heat Pump 24VAC Wiring Diagram for Heat Pump System ...

Страница 22: ...ATING 1st HEATING 2nd HEATING Transformer 2nd hea ng relay 3rd hea ng relay 1st cooling relay Fan relay AC_ IN Power Supply AC_ IN 1st Cooling 2nd Cooling Jumper Wire FAN 24VAC Heat Cool 2nd cooling relay Wiring Diagram for Conventional Heat Cool System ...

Страница 23: ...23 Notes ...

Страница 24: ...24 Notes ...

Отзывы: