– 33 –
Test Mode
Displays
T1
The display will initially show “t1”.
•
Press the
•
START button. Once the START button is pushed, the display will initially toggle
between “t1” and H3”. All LEDs turn on. This cycle will continue until the START button or
CYCLE button is pressed.
When the
•
START button is pressed, display returns to “t1”. When the CYCLE button is
pressed, the control advances to “t2”.
T2
The display will initially show “t2”.
•
Press the
•
START button. Once the START button is pushed, the display will initially toggle
between “t2” and the current revision of the software on the unit. The display will show
this until the START button or the CYCLE button is pressed.
The button operation can be checked while in this test.
•
T3
The display will initially show “t3”. When the water level increases, the display will also
•
increase.
START
•
button pressed one time – The display will toggle between “A” and the water
level. The cold valve will be energized and dispense water through the detergent
dispenser and remain this way until the START or CYCLE button is pressed.
START
•
button pressed a second time - The display will toggle between “b” and the water
level. The hot valve will be energized and remain this way until the START or CYCLE
button is pressed.
START
•
button is pressed a third time - The display will toggle between “c” and the water
level. The control will turn on the hot valve and dispense water through the pretreat
dispenser and will remain this way until the START or CYCLE button is pressed.
START
•
button is pressed a fourth time - The display will toggle between “d” and the
water level. The control will turn on the cold valve and dispense water through the
bleach dispenser. This will remain this way until the START or CYCLE button is pressed.
START
•
button is pressed a fi fth time - The display will toggle between “E” and the water
level. The control will turn on the cold valve and dispense water through the softener
dispenser. This will remain this way until the START or CYCLE button is pressed. When
the START button is pressed, display returns to “t3” test. When the CYCLE button is
pressed, exit the test and advance to next test “t4”.
In every step, the washer control should monitor the water level. When the water level
•
reaches level 7, the washer control will turn off the water valve, then exit the test to “t3”.
(Control should ignore the START button at this time in Test 3.)
T4
The display will initially show “t4”.
•
Press the
•
START button. Once the START button is pushed, the display will initially toggle
between “t4” and the water level.
The drain pump will be enabled for a maximum of 60 seconds (or until the
•
POWER or
START button is pressed). Once the 60 seconds has elapsed, the control will go back to
the “t4” state. At this time, the display will toggle between “t4” and the water level with
the drain pump off. When the START button is pressed, display returns to “t4” test. When
the CYCLE button is pressed, the system exits the test and move to next test “t5”.
(Continued Next Page)