21
Installation Instructions
CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING:
If house wiring is not 2-wire
with a ground wire, a ground must be provided
by the installer. When house wiring is aluminum,
be sure to use U.L. approved anti-oxidant compound
and aluminum-to-copper connectors.
•
Remove the 6 screws on the junction box cover
and the knockout on the top left side.
•
Secure the house wiring to the junction box
with a strain relief.
•
Connect the white lead to the branch circuit white lead.
•
Connect the black lead to the branch circuit black lead.
•
Connect the green/yellow lead to the branch
circuit green lead or bare ground lead.
•
Secure all the connections with wire nuts on each
electrical connector.
•
Push the wires into the junction box and replace
the cover. Be sure the wires are not pinched.
•
Secure the junction box cover with the 6 original
screws.
6
Junction
box cover
INSTALL DUCT COVERS
•
Remove protective plastic
covering.
•
Assemble duct covers
according to application.
NOTE:
The upper duct cover
has vent holes on one end
intended for use when the hood
is installed for recirculating
purposes. Be sure the vented
end is at the top; the vent holes
will be visible in this installation.
Slide the upper duct cover into
the folded ends of the lower duct cover.
•
Place the decorative duct covers on top of the hood.
•
Extend the inner duct cover upward to the ceiling
bracket.
•
Secure with 2 screws to the duct cover bracket.
•
Remove the packing material from the filter opening.
• Locate the screw holes on the inside front edge
of the opening. Install 2 screws to secure the lower
duct cover to the hood.
7
Mounting screws
Vent holes
Lower duct
cover seat
Duct cover
support bracket
Lower duct
cover
Upper duct
cover
Duct cover
attachment tabs
Knockout
Screw holes