Error Codes
E00 --- No error codes.
E1 --- Over flow error.
E2 --- Lid switch error. (Lid opened during run state, RPM>= 40RPM).
E3 --- Thermistor error. (ATC thermistor)
E4 --- Inlet valve failure.
E5 --- Pump failure.
E6 --- Clutch error.
E7 --- Pressure sensor failure.
E8 --- Lid switch failure. (lid opened during run state, RPM < 40RPM)
E9 --- EEprom error.
E10 --- Motor not rotating properly.
E11 --- No E11 error code.
E12 --- Clutch coupling error.
E13 --- IPM (Integrated Power Module) Thermistor. Monitors current
flow to the motor stator.
E14 --- Door lock / unlock error.
Содержание Profile PTWN8050MWW
Страница 4: ...Copyright 2011 4 Warranty ...
Страница 5: ...Copyright 2011 5 Nomenclature ...
Страница 10: ...Copyright 2011 10 HE Detergent Use Care recommends the use of HE detergent only ...
Страница 24: ...Copyright 2011 24 Control Panel Components Red LED indicates that the power board is powered and awake ...
Страница 38: ...Copyright 2011 38 Pressure Sensor Sensor is held in place by three flexible plastic tabs ...
Страница 46: ...Copyright 2011 46 Lid Hinge ...
Страница 83: ...Copyright 2011 83 Motor Bottom of tub shown will motor rotor stator completely removed ...
Страница 100: ...Copyright 2011 100 Schematic ...