Copyright 2011
97
Service Mode
Test “t6” --- Pump Check
• Press start to initiate test.
• Pump will be energized for 1 minute.
• After 1 minute, pump will turn off.
• Water frequency will be displayed.
Test “t7” --- Alpha Check (Tidal Wave Wash)
Press start to initiate test.
Tub will spin CCW at @ 230 RPM for 3 minutes.
RPM value will be displayed.
Test “t8” --- Agitate-1 Check (Centrifusion Wash)
• Press start to initiate test.
• Tub will slowly spin CW then stop then spin for 3 minutes.
• With an empty tub, “720 ~ 902 should be displayed. This
is the reading from the load sensor for an empty tub. It is
not the RPM reading of the tub speed.