BE SURE THIS CUT DOES NOT

INTERFERE WITH CABINET

STRUCTURE AT FRONT

16" MIN.

(40.6 CM)

— Printed in LaFayette, Georgia —

100% Recycled Paper

Printed LaFayette, Georgia

Recycled Paper

NOTE TO ELECTRICIAN:
The power leads supplied with this appliance
are U.L. recognized for connection to larger
gauge household wiring.  The insulation of
these leads is rated at temperatures much
higher than the temperature rating of
household wiring.  The current carrying
capacity of a conductor is governed by the
wire gauge and also the temperature rating
of the insulation around the wire.

NOTE:  ALUMINUM WIRING

A.  WARNING:

IMPROPER CONNECTION OF ALUMINUM
HOUSE WIRING TO THE COPPER LEADS
CAN RESULT IN A SERIOUS PROBLEM.

B.  Splice copper wires to aluminum wiring
using special connectors designed and
U.L. approved for joining copper to
aluminum and follow the  manufacturer’s
recommended connector procedure
closely.

NOTE:  Wire used, location and enclosure of
splices, etc., must conform to good wiring
practice and local codes.

SUGGESTED MOUNTING OF AN APPROVED

JUNCTION BOX

(NOT FURNISHED WITH UNIT)

16" MIN.

Fig. 5

BE SURE THIS CUT DOES NOT INTERFERE

WITH CABINET STRUCTURE AT FRONT

4

SR10239
Pub. No. 31-10147

229C

4053P018-4

Содержание Profile JP350AAAA

Страница 1: ...r copper wire connection only and if you have aluminum house wiring you must use special UL approved connectors for joining copper to aluminum You must use a three wire A C 208Y 120Volt or 120 240 Volt 60 Hertz electrical system A white neutral wire is not needed for this unit Refer to the rating plate on your unit for the K W rating for your counter unit SR10239 Pub No 31 10147 229C4053P018 4 STO...

Страница 2: ...pth of unprotected overhead cabinets 18 MIN height from countertop to nearest cabinet on either side of unit 1 3 4 between counter unit rear edge and wall behind unit 2 1 2 between front edge of counter unit and the front edge of the counter Fiveinches 5 minimumverticalclearancebetween the cooktop bottom and any combustible surface 19 3 8 28 1 2 20 1 2 29 1 2 28 1 2 3 3 8 1 3 4 2 1 2 MIN 19 5 8 CO...

Страница 3: ...E FASTENERS FOR ANCHORING IN CABINET SIDES CABINET SIDES Fig 4 ELECTRICAL CONNECTIONS STOP The electrical power to the counter unit supply line must be shut off while line connections are being made Failure to do so could result in serious injury or death When making the wire connections use the entire lengthofconduitprovided 3feet Theconduitmustnot be cut Connect the red and black leads from the ...

Страница 4: ...auge and also the temperature rating of the insulation around the wire NOTE ALUMINUM WIRING A WARNING IMPROPER CONNECTION OF ALUMINUM HOUSE WIRING TO THE COPPER LEADS CAN RESULT IN A SERIOUS PROBLEM B Splice copper wires to aluminum wiring using special connectors designed and U L approved for joining copper to aluminum and follow the manufacturer s recommended connector procedure closely NOTE Wir...

Страница 5: ...solamente ysielalambrado de su casa es de aluminio usted tiene que usar conectores UL aprobados especiales para juntar el cobre al aluminio Usteddebeusarunsistemaeléctricodetresalambres C A 208Y 120 Voltios 120 240 Voltios 60 Hertz Un alambre blanco neutral no es necesario para esta unidad Si no se usa el alambre blanco que viene de la fuente eléctrica de la casa se puede cubrir con una cinta y te...

Страница 6: ...d de los gabinetes sin protección de arriba 18 MIN de altura desde la superficie del mesón al gabinete a cualquier lado de la unidad 1 3 4 min entre la orilla delantera de la unidad y la orilla del frente del mesón 2 1 2 min mínimo de espacio vertical debajo del fondo de la cubierta de cocinar Cinco pulgadas 5 mínimo de espacio vertical entre el fondo de la cubierta y cualquier superficie combusti...

Страница 7: ... para pegar la unidad al mesón como se muestra STOP El poder eléctrico a los cables de la unidad de mesón debe apagarse mientras se hacen las conexiones Si esto no se hace podría resultar en heridas serias o muerte Cuando se hagan las conexiones de los alambres use el largo completo del conductor que se provee 3 pies El conductor no debe ser cortado Conecte las puntas roja y negra del conductor de...

Страница 8: ...PROVEE CON LA UNIDAD 16 MIN Fig 5 CERCIORESE DE QUE ESTE CORTE NO INTERFIERA CON LA ESTRUCTURA DEL GABINETE AL FRENTE 4 Impreso en LaFayette Georgia 100 Recycled Paper Printed LaFayette Georgia Papel Reciclado NOTA ALAMBRES DE ALUMINIO A ADVERTENCIA LAS CONEXIONES INADECUADAS DE LOS ALAMBRES DE ALUMINIO DE LACASA A LOS CONECTORES DE COBRE PUEDEN RESULTAR EN SERIOS PROBLEMAS B Conecte alambres de c...

Отзывы: