GE Profile JD968 Скачать руководство пользователя страница 14

14

Installation Instructions

Alternate Construction Preparation

Refer to the Filler or Backguard Kit
instructions for Installation details.

Optional Maintop Filler or
Backguard Kit

If counter opening extends to the wall, it
will require Maintop Filler Kit (JXS66XX)
or Backguard Kit (JXS36XX or JXS39SS)
to close the gap.

NOTE:

 If the countertop is greater than

25

, it will show a gap between the

backguard and wall or between filler kit
and the wall.

If the countertop is less than 25

, a gap

will occur between the countertop front
and the control panel ends.

(See page10, D3).

AA

Island Installation

When installing in an island or other
non-standard location, countertop cutout
dimensions must be according to page 5.

For the anti-tip bracket instructions, see
page 9.

In this application, do not use Backguard
Kit (JXS36XX or JXS39SS).

AB

Cabinets Over The Range
Less Than 30

If a 30

 clearance between cooking

surface and overhead combustible
material or metal cabinets cannot be
maintained, protect the underside of
the cabinets above the cooktop with
not less than 1/4

 insulating millboard

covered with sheet metal not less than
0.0122

 thick.

AC

Wall

Must Be
Flat

Must Be
Flat

Must Be
Level

Must Be Level

30

Smooth Cut

9/16

9/16

25

Содержание Profile JD968

Страница 1: ...ed ATTENTION INSTALLER All electric drop in ranges must be hard wired direct wired into an approved junction box A plug and receptacle is NOT permitted on these products If you have questions call 1 8...

Страница 2: ...onal Electrical Code ANSI NFPA No 70 Latest Edition You can get a copy by writing National Fire Protection Association Batterymarch Park Quincy MA 02269 Effective January 1 1996 the National Electrica...

Страница 3: ...not use hand trucks when moving the unpackaged range Cooktop glass may be broken To obtain Kits a Visit GE Web Site See page 1 b Call GE Answer Center See page 1 c Contact Dealer Do not remove the pro...

Страница 4: ...Required Clearances A If cabinets are placed less than 30 min above the range see alternate construction 30 ranges conform to U L requirements for 0 spacing from vertical walls below countertops Allo...

Страница 5: ...age and voiding the warranty Center the 30 wide opening over the adjacent cabinets and mark with a straight edge Using a straight edge mark the back line at 23 3 16 from the front edge of the counter...

Страница 6: ...ED FROM THE LEADS NO CONDUCTOR SHALL BE EXPOSED IN THE CONNECTION THE EXCEPTION TO THE CONDUCTOR BEING EXPOSED IS THE BARE COPPER GROUND CONNECTION Position the range in front of the opening but sligh...

Страница 7: ...codes do not permit grounding through neutral Cut the neutral white lead from the crimp Re strip the neutral white lead to expose the proper length of conductor and connect it to the white or gray br...

Страница 8: ...clamp of the proper size is obtained NOTE TO ELECTRICIAN The 3 power leads supplied with this appliance are UL recognized for connection to larger gauge household wiring The insulation of these 3 lead...

Страница 9: ...n D1 Continued on following page 1 For 3 4 Counter 2 For 1 18 3 cm Counter 3 For 1 5 Counter 4 For 3 5 5 Alternate shown below Anti Tip Bracket Location Rear of Range Glass Cooktop ANTI TIP INSTALLATI...

Страница 10: ...nto the Opening It is suggested that two people lift the range into place carefully setting the side metal flanges under the glass on the edges of the countertop opening The protective channels must b...

Страница 11: ...the countertop If the screws do not meet the requirements move the screws to a position that meets these requirements See illustration below D5 Remove the Protective Channels if provided Carefully re...

Страница 12: ...ructionscont D NOTE The oven door is heavy You may need help lifting the door high enough to slide it into the hinge slots Do not lift the door by the handle D7 D8 Bottom Edge of Slot Hinge Arm Hinge...

Страница 13: ...diately Recheck the range wiring connections If change is made to connections retest again If no change is required have building wiring checked for proper connections and voltage It is recommended th...

Страница 14: ...ountertop front and the control panel ends See page10 D3 AA Island Installation When installing in an island or other non standard location countertop cutout dimensions must be according to page 5 For...

Страница 15: ...15 NOTES...

Страница 16: ...16 NOTES 31 10622 1 1 07 JR...