Installation Instructions

Lift the oven door by
placing one hand on
each side. The door is
heavy, so you may need
help. Do not lift the door
by the handle.

With the door at the same angle as
the removal position (halfway between
the closed and broil stop position,
seat the notch of the hinge arm into
the bottom edge of the hinge slot.
The notch of the hinge arm must be
fully seated into the bottom of the slot.

Push the hinge locks up against the
front frame of the oven cavity, to the
locked position.

Close the oven door.

Standard Installation Instructions

 cont.

D

NOTE: The oven door is heavy. You
may need help lifting the door high
enough to slide it into the hinge slots.
Do not lift the door by the handle.

D7

D8

Bottom Edge
of Slot

Hinge Arm

Hinge Notch

Notch of Hinge
Securely Fitted
into Bottom of
Hinge Slot

Hinge in
Locked Position

Replacing the Oven Door

Open the oven door as far as it
will open.

D9

D10

D11

Check for Proper Installation
of Anti-Tip Bracket

Lower the oven door and gently apply
medium force at the handle end until
movement of the range is detected.
Continue pressing until the anti-tip
bracket is engaged and movement
stops. A small amount of movement is
acceptable at the back of the range
top, but it should be stable and not tip
once the anti-tip bracket is engaged.

D12

Содержание Profile JD968

Страница 1: ...ed ATTENTION INSTALLER All electric drop in ranges must be hard wired direct wired into an approved junction box A plug and receptacle is NOT permitted on these products If you have questions call 1 8...

Страница 2: ...onal Electrical Code ANSI NFPA No 70 Latest Edition You can get a copy by writing National Fire Protection Association Batterymarch Park Quincy MA 02269 Effective January 1 1996 the National Electrica...

Страница 3: ...not use hand trucks when moving the unpackaged range Cooktop glass may be broken To obtain Kits a Visit GE Web Site See page 1 b Call GE Answer Center See page 1 c Contact Dealer Do not remove the pro...

Страница 4: ...Required Clearances A If cabinets are placed less than 30 min above the range see alternate construction 30 ranges conform to U L requirements for 0 spacing from vertical walls below countertops Allo...

Страница 5: ...age and voiding the warranty Center the 30 wide opening over the adjacent cabinets and mark with a straight edge Using a straight edge mark the back line at 23 3 16 from the front edge of the counter...

Страница 6: ...ED FROM THE LEADS NO CONDUCTOR SHALL BE EXPOSED IN THE CONNECTION THE EXCEPTION TO THE CONDUCTOR BEING EXPOSED IS THE BARE COPPER GROUND CONNECTION Position the range in front of the opening but sligh...

Страница 7: ...codes do not permit grounding through neutral Cut the neutral white lead from the crimp Re strip the neutral white lead to expose the proper length of conductor and connect it to the white or gray br...

Страница 8: ...clamp of the proper size is obtained NOTE TO ELECTRICIAN The 3 power leads supplied with this appliance are UL recognized for connection to larger gauge household wiring The insulation of these 3 lead...

Страница 9: ...n D1 Continued on following page 1 For 3 4 Counter 2 For 1 18 3 cm Counter 3 For 1 5 Counter 4 For 3 5 5 Alternate shown below Anti Tip Bracket Location Rear of Range Glass Cooktop ANTI TIP INSTALLATI...

Страница 10: ...nto the Opening It is suggested that two people lift the range into place carefully setting the side metal flanges under the glass on the edges of the countertop opening The protective channels must b...

Страница 11: ...the countertop If the screws do not meet the requirements move the screws to a position that meets these requirements See illustration below D5 Remove the Protective Channels if provided Carefully re...

Страница 12: ...ructionscont D NOTE The oven door is heavy You may need help lifting the door high enough to slide it into the hinge slots Do not lift the door by the handle D7 D8 Bottom Edge of Slot Hinge Arm Hinge...

Страница 13: ...diately Recheck the range wiring connections If change is made to connections retest again If no change is required have building wiring checked for proper connections and voltage It is recommended th...

Страница 14: ...ountertop front and the control panel ends See page10 D3 AA Island Installation When installing in an island or other non standard location countertop cutout dimensions must be according to page 5 For...

Страница 15: ...15 NOTES...

Страница 16: ...16 NOTES 31 10622 1 1 07 JR...

Отзывы: