background image

1

Before You Begin

Read these instructions carefully and completely.

IMPORTANT

—Save these

instructions for local inspector’s use.

IMPORTANT

—Observe all

governing codes and ordinances.

• Note to Installer—Be sure to leave these

instructions with the consumer.

• Note to Consumer—Keep these

instructions for future reference.

• Proper installation is the responsibility

of the installer and product failure due
to improper installation is NOT covered
under the warranty.

• NOTE—This appliance must be properly

grounded.

ATTENTION INSTALLER

All electric drop-in ranges must be hard
wired (direct wired) into an approved
junction box. A plug and receptacle is NOT
permitted on these products.

If you have questions, call 1.800.GE.CARES or visit our website at:
ge.com

Self-Cleaning Radiant
Electric Drop-In Range

Installation
Instructions

JDP47, JD968, JD900

Materials Needed

Junction Box

Wire Nuts

Strain Relief Clamp
for 1/2

 conduit

Parts Included

Lower Trim
2 Screws

2 Shoulder Screws
(for stop device)

Tools You Will Need

1/8

 Drill Bit and

Electric or Hand Drill

Phillips Screwdriver

Nut Driver

Level

Tape Measure

Straight Edge
or Square

Hand or Sabre Saw

Standard Screwdriver

Pencil

Safety Glasses

Hammer

31-10622-1 

       1-07  JR

Содержание Profile JD968

Страница 1: ...ed ATTENTION INSTALLER All electric drop in ranges must be hard wired direct wired into an approved junction box A plug and receptacle is NOT permitted on these products If you have questions call 1 8...

Страница 2: ...onal Electrical Code ANSI NFPA No 70 Latest Edition You can get a copy by writing National Fire Protection Association Batterymarch Park Quincy MA 02269 Effective January 1 1996 the National Electrica...

Страница 3: ...not use hand trucks when moving the unpackaged range Cooktop glass may be broken To obtain Kits a Visit GE Web Site See page 1 b Call GE Answer Center See page 1 c Contact Dealer Do not remove the pro...

Страница 4: ...Required Clearances A If cabinets are placed less than 30 min above the range see alternate construction 30 ranges conform to U L requirements for 0 spacing from vertical walls below countertops Allo...

Страница 5: ...age and voiding the warranty Center the 30 wide opening over the adjacent cabinets and mark with a straight edge Using a straight edge mark the back line at 23 3 16 from the front edge of the counter...

Страница 6: ...ED FROM THE LEADS NO CONDUCTOR SHALL BE EXPOSED IN THE CONNECTION THE EXCEPTION TO THE CONDUCTOR BEING EXPOSED IS THE BARE COPPER GROUND CONNECTION Position the range in front of the opening but sligh...

Страница 7: ...codes do not permit grounding through neutral Cut the neutral white lead from the crimp Re strip the neutral white lead to expose the proper length of conductor and connect it to the white or gray br...

Страница 8: ...clamp of the proper size is obtained NOTE TO ELECTRICIAN The 3 power leads supplied with this appliance are UL recognized for connection to larger gauge household wiring The insulation of these 3 lead...

Страница 9: ...n D1 Continued on following page 1 For 3 4 Counter 2 For 1 18 3 cm Counter 3 For 1 5 Counter 4 For 3 5 5 Alternate shown below Anti Tip Bracket Location Rear of Range Glass Cooktop ANTI TIP INSTALLATI...

Страница 10: ...nto the Opening It is suggested that two people lift the range into place carefully setting the side metal flanges under the glass on the edges of the countertop opening The protective channels must b...

Страница 11: ...the countertop If the screws do not meet the requirements move the screws to a position that meets these requirements See illustration below D5 Remove the Protective Channels if provided Carefully re...

Страница 12: ...ructionscont D NOTE The oven door is heavy You may need help lifting the door high enough to slide it into the hinge slots Do not lift the door by the handle D7 D8 Bottom Edge of Slot Hinge Arm Hinge...

Страница 13: ...diately Recheck the range wiring connections If change is made to connections retest again If no change is required have building wiring checked for proper connections and voltage It is recommended th...

Страница 14: ...ountertop front and the control panel ends See page10 D3 AA Island Installation When installing in an island or other non standard location countertop cutout dimensions must be according to page 5 For...

Страница 15: ...15 NOTES...

Страница 16: ...16 NOTES 31 10622 1 1 07 JR...

Отзывы: