– 50 –
Oven Sensor and Lock Switch Connector (Dual Fuel Range) J2S968
BAKE
RELAY
BAKE
L1
"L1"
BLACK
BROIL
RELAY
L1
BROIL
*Approximately 25% on time in Bake.
Bake & Broil relays cannot be on at same time.
There is approx. 1 min. of dead time between
bake and broil unit operation after preheat.
Bake and broil units operate sequentially during first
(preheat)cycle.
** 1 second dead time between bake and broil
units while calling for heat in clean.
"L2"
RED
"L1"
BLACK
L1
BROIL
"L2"
RED
BROIL
RELAY
2700W/16.8
3600 W / 16
BAKE & TIME BAKE*,
BROIL & CLEAN-UNTIL
AFTER 750˚F IS REACHED
3600W/16.4
14.2A
15A
15A
BK
BR
BR
DLB
RELAY
DLB
RELAY
1
2
3
4
5
6
7
8
OVEN TEMP SENSOR
1100
Ω
@ ROOM TEMP
2650
Ω
@ CLEAN TEMP
UNLOCK
SW 2
MEAT PROBE*
50K @ RM
CONTROL
CONNECTOR
PLUG
THERMAL SWITCH (BAKE)
OPEN @169˚F
CLOSES @140˚F
1
1
THERMAL SWITCH
OPEN @240˚F
CLOSES @190˚F
2
2
L2
L1
L-1
CONVECTION
BAKE ELE.
2500W
CONVECTION BAKE
240V.
10.4A
10.4A
CONV-1
DLB
RELAY
N
L1-1
DOOR
SW
NO
C
CONVEC
M
CONVECTION
FAN
CW
CCW
BROIL-1
L2
L1
N
L-1
L1-1
DOOR
SW
BROIL
4000W
14.4A
CONVECTION ROAST
NO
C
240V.
15A
15A
CONVEC
DLB
RELAY
M
CONVECTION
FAN
CW
CCW
Содержание Profile J2S968 SERIES
Страница 57: ... 57 All Gas Range Schematic with Convection Fan JGS968 ...
Страница 58: ... 58 All Gas Range Wiring Diagram with Convection Fan JGS968 ...
Страница 59: ... 59 Dual Fuel Range Schematic J2S968 ...
Страница 60: ... 60 Dual Fuel Range Wiring Diagram J2S968 ...
Страница 61: ... 61 Notes ...
Страница 62: ... 62 Notes ...
Страница 63: ... 63 Notes ...