– 35 –
To remove the pump:
Remove the front panel. (See
1.
Front Panel
.)
Caution: Under normal conditions, approximately
1 quart of water will drain out when the pump
cleanout is removed.
Place a shallow pan under the drain cleanout.
2.
Turn the pump cleanout counterclockwise
3.
approximately 2 turns, then pull outward.
Strainer
Note: Remove any debris or foreign objects from the
strainer and interior of the pump before reinstalling.
Remove the drain hoses from the pump:
4.
Note: The drain hoses are diffi cult to remove.
Squeeze each clamp and slide it back.
a.
Carefully break each hose loose by inserting
b.
a small fl at blade screwdriver under the
hose to break the seal.
Remove the tub outlet hose from the pump
c.
inlet.
Remove the drain hose from the pump
d.
outlet.
Disconnect the 2 wires from the pump.
5.
Remove the 2 Phillips-head screws that hold the
6.
pump to the chassis.
Pull the pump rearward to clear the 2 locator
7.
pins from the 2 grommets in the front frame.
Drain Hose
Tub
Outlet
Hose
Pump
Wires
Remove the pump through the enlarged
8.
opening on the left side of the front frame.
Note: Before installing the clamp, align the notch
in the drain hose with the raised ridge on the pump
outlet.
Locator Pins
Ridge
Notch