CONVERT SURFACE BURNERS

First remove, convert and replace the left side surface
burners and then the right side surface burners.

Remove the grates, burner caps and burner heads.
Remove the screws securing the burner bases 
to the burners. Pull out the electrodes without
removing the electrode leads.

A

Conversion Instructions

With the installation of this conversion kit, the cooktop
should operate on either natural gas at 4

of water

column or LP gas at 10

of water column pressure.

The pressure regulator must be connected in series
with the manifold of the cooktop and must remain in
series with the supply line. For proper operation, the
maximum inlet pressure to the regulator must be no
more than 10

water column pressure for natural gas

and 14

water column pressure for LP gas.

When checking the regulator, the inlet pressure must
be at least 1

greater than the regulator output

setting. If the regulator is set for 4

of water column

pressure, the inlet pressure must be at least 5

. If the

regulator is set for 10

of water column pressure, the

inlet pressure must be at least 11

.

IMPORTANT –

Disconnect the cooktop and

the individual shut-off valve from the gas supply piping
system during any pressure testing of that system at test
pressures greater than 1/2 psig. Isolate the cooktop from
the gas supply piping system by closing the individual
manual shut-off valve to the cooktop during any pressure
testing of the gas supply piping system at test pressures
equal to or greater than 1/2 psig.

GAS SUPPLY

BEFORE YOU BEGIN, TURN OFF THE GAS SUPPLY AT THE
SHUT-OFF VALVE. DISCONNECT THE ELECTRICAL SUPPLY
FROM THE COOKTOP.

TURN OFF GAS AND
ELECTRIC SUPPLY

1

Remove the brass orifice spud in the chimney 
of each burner using a 9/32

(7 mm) nutdriver.

B

Grate

Burner cap

Electrode

Burner base

Burner head

Burner base

screw (2)

Install the high altitude orifice spuds in their correct
positions by number.

C

Natural Gas High Altitude Orifices – 5000 ft.

Location

BTUs

Orifice Size

Marking

LF, LR

7644

1.40 mm

140 N

RR

4620

1.12 mm

112 N

RF

9660

1.51 mm

151 N

Shut-off valve

Front

2

Electrical supply

LR

LF

RR

RF

Replace the gaskets, burner bases and electrodes.
Install the two screws in each burner base. Do not
overtighten. The maximum torque is 10 inch pounds.
Push the igniters all the way down into the burner
head.

Install the burner heads, burner caps and grates 
in their original burner positions.

E

D

LP Gas High Altitude Orifices – 5000 ft.

Location

BTUs

Orifice Size

Marking

LF, LR

7140

.80 mm

80 L

RR

4620

.66 mm

66 L

RF

9240

.91 mm

91 L