CONVERT SURFACE BURNERS
First remove, convert and replace the left side surface
burners and then the right side surface burners.
Remove the grates, burner caps and burner heads.
Remove the screws securing the burner bases
to the burners. Pull out the electrodes without
removing the electrode leads.
A
Conversion Instructions
•
With the installation of this conversion kit, the cooktop
should operate on LP gas at 10
″
of water column
pressure.
•
The pressure regulator must be connected in series
with the manifold of the cooktop and must remain in
series with the supply line. For proper operation, the
maximum inlet pressure to the regulator must be no
more than 14
″
water column pressure for LP gas.
•
When checking the regulator, the inlet pressure must
be at least 1
″
greater than the regulator output
setting. If the regulator is set for 10
″
of water column
pressure, the inlet pressure must be at least 11.
″
IMPORTANT –
Disconnect the cooktop and
the individual shut-off valve from the gas supply piping
system during any pressure testing of that system at test
pressures greater than 1/2 psig. Isolate the cooktop from
the gas supply piping system by closing the individual
manual shut-off valve to the cooktop during any pressure
testing of the gas supply piping system at test pressures
equal to or greater than 1/2 psig.
GAS SUPPLY
BEFORE YOU BEGIN, TURN OFF THE GAS SUPPLY AT THE
SHUT-OFF VALVE. DISCONNECT THE ELECTRICAL SUPPLY
FROM THE COOKTOP.
TURN OFF GAS AND
ELECTRIC SUPPLY
L
L
84
84
L
L
71
99
1
Remove the brass orifice spud in the chimney
of each burner using a 9/32
″
(7 mm) nutdriver.
B
Grate
Burner cap
Electrode
Burner base
Burner head
Burner
base
screw (2)
Install the LP orifice spuds in their correct positions
by number.
Note:
The LP orifices are shorter than the
natural gas orifices.
C
LP (Propane) Gas 10
″
W.C.P.
Burner Output Rating in BTU/HR
Location
BTUs
Orifice Size
LF, LR
8,500
0.84 Lmm
RR
5,500
0.71 Lmm
RF
11,000
0.99 Lmm
Shut-off valve
Front
2
Electrical supply
Use for cooktop operation at elevations above 5000 ft. (1500m).
Specify kit for Natural Gas or LP Gas when ordering:
Natural Gas High Altitude Orifice Conversion Kit.........WB28X10114
LP High Altitude Orifice Conversion Kit..................................WB28X10115
High Altitude Orifice Conversion Kit