– 51 –
Retainer
To remove the duct heater:
Remove the freezer evaporator cover (See
1.
Freezer Evaporator Cover.
) and place the cover
assembly on a protected surface so that the
inside faces upward.
Note the positioning of the wiring and untape
2.
the wire harnesses.
Remove the 2 plastic wire ties (not shown) and
3.
the duct heater wires from all retainers.
Duct Heater
Wire Harness
The heater can be checked directly as a separate
component by removing the freezer evaporator
cover (See
Freezer Evaporator Cover
.) The heater wire
harness can then be disconnected.
The duct heater has a resistance value of
approximately 3.18K
Ω
.
(
Continued next page
)
4. Press inward the top and bottom tabs and pull
the duct assembly from the ice room blower
housing.
Bottom Tab
Top Tab
Top View of Duct
Bottom View of Duct
EMI Filter and Power Cord
It is necessary to remove the EMI
fi
lter to replace the
power cord. The power cord is connected to the EMI
fi
lter with a wire harness.
To remove the EMI fi lter and power cord:
Remove the machine compartment cover. (See
1.
Machine Compartment Cover
.)
Remove the Phillips-head screws that hold the
2.
EMI
fi
lter bracket, water valve, power cord, and
ground wires to the cabinet.
Disconnect the EMI
fi
lter wire harness.
3.
Disconnect