Copyright General Electric 2011
Heater Basic Operation
Duct Port heater
- cycles based on temperatures and ice box condition. (Ex: mid –mid settings
appx 30% on time.) Located around the holes for ice door.
Supply Duct heater
- come on with abnormally high door opening time and high room humidity
Air Duct heater
(abnormal is appx. 70 FF openings for 12 sec. or more in 16 hours)
Door Gasket heater
- are on all of the time with a FZ setting of 4 or lower. Above that varies.
Recess
Duct door
Fill Tube heater
- on for 2 hours after water valve activation or when ice is dispensed.
Содержание PFSS5R
Страница 1: ...Bottom Freezer with Ice Water in Door PGCS1R PFCF1R PFSS5R PGSS5R BJ 5 11 ...
Страница 4: ...Copyright General Electric 2011 ...
Страница 6: ...New Ice Water Section ...
Страница 7: ...Copyright General Electric 2011 New Ice and Water in Door Lift slightly up to remove bucket ...
Страница 8: ...Copyright General Electric 2011 Bucket holds approximately 4 lbs Ice Operation ...
Страница 9: ...Copyright General Electric 2011 Cubes Crushed Ice Operation ...
Страница 16: ...Copyright General Electric 2011 Ice Bucket Bucket holds approximately 4 lbs 6 Bucket appx 6 deep and 9 wide 9 ...
Страница 17: ...Copyright General Electric 2011 Bucket held in place with guides Inside Ice room area Ice Bucket ...
Страница 20: ...Copyright General Electric 2011 Ice Auger Assembly Comes as an assembly or in parts ...
Страница 26: ...Copyright General Electric 2011 Ice Maker Testing Orange and Brown wire connectors ...
Страница 28: ...Copyright General Electric 2011 Auger Motor Remove auger fork by removing nut ...
Страница 29: ...Copyright General Electric 2011 Auger Motor Components come as shown ...
Страница 31: ...Copyright General Electric 2011 Ice Door Air Vent Pry gently off Turn slightly clockwise and pull straight off ...
Страница 32: ...Copyright General Electric 2011 Ice Door Air Vent Non replaceable part Screw comes in from backside ...
Страница 33: ...Copyright General Electric 2011 Water Lines Water line connections on lower right hand corner of FF section ...
Страница 34: ...Fan Section ...
Страница 35: ...Copyright General Electric 2011 Evaporator Fan ...
Страница 36: ...Copyright General Electric 2011 Freezer Evaporator Fan Remove fan cover screw and swing off ...
Страница 39: ...Copyright General Electric 2011 Ice Fan Duct ...
Страница 40: ...Copyright General Electric 2011 Ice Fan Duct 12VDC 3 speed fan ...
Страница 42: ...Copyright General Electric 2011 Ice Fan Testing J2 ...
Страница 43: ...Copyright General Electric 2011 Ice Fan Duct Blower comes as an assembly Rubber boot separate part ...
Страница 49: ...New LED Lighting ...
Страница 50: ...Copyright General Electric 2011 All LED Lighting 9 LED light pads in FF 1 LED light pad in FZ ...
Страница 53: ...Copyright General Electric 2011 LED Lighting Freezer LED is on ceiling in the middle ...
Страница 56: ...Heaters ...
Страница 64: ...Door Drawer Section Structure ...
Страница 66: ...Copyright General Electric 2011 Top Freezer Drawer Top drawer shelf lifts straight up ...
Страница 69: ...Copyright General Electric 2011 Lower Freezer Drawer Remove hex head screw from each side ...
Страница 74: ...Copyright General Electric 2011 Fresh Food Left door with Ice Water Remove 1 screw securing cover Remove cover ...
Страница 82: ...Copyright General Electric 2011 Fresh Food Right Door Deep large bins on door ...
Страница 85: ...Thermistors ...
Страница 89: ...Copyright General Electric 2011 WR97X163 Silicone grease WR01X10466 Bell Connector Thermistors Replacing ...
Страница 92: ...Main Control Board and Dispenser Board ...
Страница 95: ...Copyright General Electric 2011 Dispenser Board Duct door heater location ...
Страница 97: ...Copyright General Electric 2011 Main Control Board ...
Страница 98: ...Copyright General Electric 2011 Main Board A C ...
Страница 99: ...Copyright General Electric 2011 Main Board D C ...
Страница 100: ...Compressor Inverter ...
Страница 101: ...Copyright General Electric 2011 Compressor Inverter Three speed three phase inverter controlled compressor ...
Страница 103: ...Copyright General Electric 2011 Inverter Compressor Testing 1 4 6VDC 2 120VAC 3 10 ohms ...
Страница 104: ...Copyright General Electric 2011 End of presentation for BM with Ice Water in the door ...