GE Energy Motors GEEP-427-I Copyright 2009, The General Electric Company, USA
31
GEEP-427-I Pegasus, Horizontal Induction Motor
TEWAC, Sleeve Bearing
Operational Difficulties
WARNING: HIGH VOLTAGE AND
ROTATING PARTS CAN CAUSE SERIOUS INJURY.
THE USE OF ELECTRIC MACHINERY, LIKE ALL
OTHER UTILIZATION OF CONCENTRATED POWER
AND ROTATING PARTS, CAN BE HAZARDOUS.
MAKE CERTAIN THAT THE VOLTAGE IS REMOVED
FROM ALL CIRCUITS AND THAT NO MECHANICAL
PARTS ARE ROTATING. INSTALLATION,
OPERATION AND MAINTENANCE OF ELECTRIC
MACHINERY SHOULD BE PERFORMED BY
QUALIFIED PERSONNEL. FAMILIARIZATION WITH
NEMA PUBLICATION MG-2, SAFETY STANDARDS
FOR CONSTRUCTION AND GUIDE FOR
SELECTION, INSTALLATION AND USE OF
ELECTRIC MOTORS AND GENERATORS, THE
NATIONAL ELECTRICAL CODE AND SOUND
LOCAL PRACTICES IS RECOMMENDED.
TROUBLE - SHOOTING CHART
Trouble Possible
Cause
Action
Motor will not start
Power not connected
Connect power to control, and control
to motor. Check contacts.
Low Voltage
Check motor nameplate value with bus
voltage.
Wrong control connections
Check connections with control wiring
diagram.
Driven machine locked
Disconnect motor from load. If motor
starts satisfactorily, check driven
machine.
Open circuit in stator or rotor
winding
Measure/compare winding resistance
of each phase.
Winding grounded
Test for grounded winding.
Excessive load torque
Check motor capability.
Overload control trip
Wait for motor to cool. Try starting
again.
Noise or vibration
Motor running single phase
Stop motor. Then try to start. It will not
start on single phase. Check for
“Open” in one of the lines or circuits.
Supply bus unbalanced
Check balance by measuring current
and voltage in each phase. Correct the
power supply to obtain balanced
voltages.
TROUBLE - SHOOTING CHART
Содержание Pegasus MHV GEEP-427-I
Страница 46: ...GE Energy Motors 46 ...