7
INSTALLATION
IMPORTANT - OBSERVE ALL GOVERNING CODES
Dryer must be levelled and rest firmly on the floor.
WARNING: THE 208/240V DRYER MUST BE INSTALLED WITH
CONTROL PANEL AT BOTTOM IN ORDER TO OPERATE ADEQUATELY
SPECIAL INSTALLATION REQUIREMENTS
ALCOVE OR CLOSET INSTALLATION
• WARNING: To reduce the risk of fire, this dryer
MUST BE EXHAUSTED TO THE OUTDOORS.
See EXHAUST INFORMATION section.
• Minimum clearances between dryer cabinet and
adjacent walls or other surfaces are:
0” either side
1” front and rear
• Minimum vertical space from floor to overhead
cabinets, ceilings, etc. is 52”.
• Closet door must be louvered or otherwise ventilated
and must contain a minimum of 60 sq. in. of open
area equally distributed. If this closet contains both a
washer and a dryer, doors must contain a minimum of
120 sq. in. of open area equally distributed.
• No other fuel-burning appliance shall be installed in
the same closet with the dryer.
MINIMUM CLEARANCES OTHER THAN
ALCOVE OR CLOSET INSTALLATIONS.
• Minimum clearances to combustible surfaces:
0 clearance both sides and 25 mm (1”) rear.
MOBILE HOME INSTALLATION
• The dryer must be exhausted to the outdoors with the
termination securely fastened to the mobile home
structure. (See EXHAUST INFORMATION section.)
• The exhaust MUST NOT be terminated beneath the
mobile home.
• Provisions must be made for the introduction of
outside air into the dryer. The free air opening shall
not be less than 80 cm
2
(12 in
2
).
• The exhaust duct material MUST BE METAL.
• The dryer must be attached to the floor following
instructions available from the dealer.
• Installation must comply with the current CAN/CSA
Z240 MH series Mobile Home Installation Codes.
ELECTRICAL POWER SUPPLY
CAUTION: NEVER USE AN EXTENSION CORD WITH THIS APPLIANCE.
Note: If the electrical power supply provided does not meet the specifications listed below, call a licensed electrician.
FOR 120/240 V DRYERS, POWER SUPPLY...
1. Must be of 120/240 volts or 120/208 volts, 60 Hz
circuit with wall receptacle as
shown beside.
2. Must be protected with 30A
FUSES OR BREAKERS.
3. Must be WELL GROUNDED.
4. Must CONFORM TO LOCAL
CODES.
FOR 120V DRYERS, POWER SUPPLY...
1. Must be of 120 volts, 60 Hz
circuit with wall receptacle as
shown beside.
2. Must be protected with 15 or
20A FUSES OR BREAKER.
3. Must be WELL GROUNDED.
4. Installation must be in accordance
with the current CSA C22.1 Canadian Electrical code
part 1 and/or local codes.
• This dryer must be connected to an individual circuit
identical to the one specified on the rating plate of
the loading port, protected by fuses or circuit breaker
conforming to local codes. THIS APPLIANCE
MUST BE PROPERLY GROUNDED.
• The power cord of this appliance is equipped with a
three (3) or four (4) prong plug which mates with an
appropriate dryer wall receptacle.
GROUNDING INSTRUCTIONS
• This appliance must be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electric shock by providing a path of least
resistance for electric current. The plug must be
plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local
codes and ordinances.\
WARNING:
• Improper connection of the equipment grounding
conductor can result in a risk of electric shock.
Check with a qualified electrician or serviceman if
you are in doubt as to whether the appliance is
properly grounded.
• Do not modify the plug provided with the appliance
– if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
NOTE: CONSIDERATION MUST BE GIVEN TO INSTALLING AND SERVICING THE APPLIANCE.
Installation
Содержание PCKS443EBWW
Страница 15: ...15 NOTES ...
Страница 31: ...15 NOTES ...