Installation Instructions
39
WARNING
INSTALLATION SAFETY
INSTRUCTIONS
Read these instructions completely and carefully.
Improper installation, adjustment, alteration, service
or maintenance can cause injury or property damage.
Refer to this manual. For assistance or additional
information, consult a qualified installer, service
agency, manufacturer (dealer) or the gas supplier.
Never.reuse.old.flexible.connectors ..The.use.of.old.
flexible.connectors.can.cause.gas.leaks.and.personal.
injury ..Always.use.
NEW
.flexible.connectors.when.
installing.a.gas.appliance .
Leak.testing.of.the.appliance.shall.be.conducted.
according.to.the.manufacturer.instructions .
IMPORTANT
.–.
Remove.all.packing.material.
and.literature.from.oven.before.connecting.gas.and.
electrical.supply.to.range .
CAUTION
..
Do.not.attempt.to.operate.
the.oven.of.this.range.during.a.power.failure.(Electric.
Ignition.models.only) .
..Have.your.range.installed.by.a.qualified.installer .
..Your.range.must.be.electrically.grounded.in.
accordance.with.local.codes.or,.in.the.absence.of.
local.codes,.in.accordance.with.the.National.Electrical.
Code.(ANSI/NFPA.70,.latest.edition) ..In.Canada,.
electrical.grounding.must.be.in.accordance.with.the.
current.CSA.C22 .1.Canadian.Electrical.Code.Part.1.
and/or.local.codes ..See.
Electrical Connections
.in.this.
section .
..Before.installing.your.range.on.linoleum.or.any.other.
synthetic.floor.covering,.make.sure.the.floor.covering.
can.withstand.180°F.without.shrinking,.warping.or.
discoloring ..Do.not.install.the.range.over.carpeting.
unless.a.sheet.of.1/4
”
.thick.plywood.or.similar.
insulator.is.placed.between.the.range.and.carpeting .
..Make.sure.the.wall.coverings.around.the.range.can.
withstand.heat.generated.by.the.range.up.to.200°F .
..Avoid.placing.cabinets.above.the.range ..To.reduce.
the.hazard.caused.by.reaching.over.the.open.flames.
of.operating.burners,.install.a.ventilation.hood.over.
the.range.that.projects.forward.at.least.5
”
.beyond.
the.front.of.the.cabinets .
..The.ventilating.hood.must.be.constructed.
of.sheet.metal.not.less.than.0 .0122
”
.thick ..
Install.above.the.cooktop.with.a.clearance.of.not.
less.than.1/4
”
.between.the.hood.and.the.underside.
of.the.combustible.material.or.metal.cabinet ..The.
hood.must.be.at.least.as.wide.as.the.appliance.and.
centered.over.the.appliance ..Clearance.between.the.
cooking.surface.and.the.ventilation.hood.surface.
MUST NEVER BE LESS THAN 24
”
.
EXCEPTION:
Installation.of.a.listed.microwave.oven.or.
cooking.appliance.over.the.cooktop.shall.conform.to.
the.installation.instructions.packed.with.that.appliance .
..If.cabinets.are.placed.above.the.range,.
allow.a.minimum.clearance.of.30
”
.between.the.
cooking.surface.and.the.bottom.of.unprotected.
cabinets .
..If.a.30
”
.clearance.between.cooking.surface.and.
overhead.combustible.material.or.metal.cabinets.
cannot.be.maintained,.protect.the.underside.of.the.
cabinets.above.the.cooktop.with.not.less.than.1/4
”
.
insulating.millboard.covered.with.sheet.metal.not.less.
than.0 .0122
”
.thick ..Clearance.between.the.cooking.
surface.and.protected.cabinets.
MUST NEVER BE LESS
THAN 24
”
.
..The.vertical.distance.from.the.plane.of.the.cooking.
surface.to.the.bottom.of.adjacent.overhead.cabinets.
extending.closer.than.1
”
.to.the.plane.of.the.range.
sides.must.not.be.less.than.18
”
..(See.the.Dimensions.
and.Clearances. illustration.in.this.section .)
CAUTION
-
Only the GE Caf
é
branded series
of Advantium
®
or microwave over-the-range ovens are
designed to be installed above the GE Caf
é
range.
.Surfaces.
above.a.gas.range.can.become.hot ..Installation.of.any.other.
over-the-range.oven.above.a.GE.Café.range.may.result.in.
surface.temperatures.that.can.cause.burns .
Содержание PCGB995