![GE PanaFlow XMT1000 Скачать руководство пользователя страница 47](http://html.mh-extra.com/html/ge/panaflow-xmt1000/panaflow-xmt1000_user-manual_132849047.webp)
PanaFlow™ XMT1000 User’s Manual
35
Appendix B. Modbus Communication
Appendix B. Modbus Communication
B.1 Modbus Protocol
In general, the PanaFlow XMT1000 flow meter follows the standard Modbus communications protocol defined by the
reference MODBUS APPLICATION PROTOCOL SPECIFICATION V1.1b. This specification is available at
www.modbus.org on the Internet. With this reference as a guide, an operator could use any Modbus master to
communicate with the flow meter.
Listed below are two limits of this implementation:
•
The PanaFlow XMT1000 supports only four of the standard function codes. These are Read Holding Registers
(0x03), Read Input Registers (0x04), Write Multiple Registers (0x10), and Read File Record (0x14).
and
•
The flow meter needs a 15 msec gap between Modbus requests. The prime objective of the flow meter is to
measure flow, so the Modbus server has a low priority.
B.2 Modbus Register Map
Table 6: XMT1000 Modbus Register Map - Revision 4.19
Reg #
in Hex
Access
Level
Register ID Description
Units
RO/RW
Size in
Bytes
Format
Health Check + Identification (Input Registers)
210
210
NONE
Product Type
unitless
RO
4
INT32
System Real RW
400
System Int RW
500
500
Operator eUnit_ActVol Global Unit group 1 for
Actual Volumetric
unitless
RW
4
INT32
502
Operator
eUnit_Day
Global Unit group 2 for
Day
unitless
RW
4
INT32
504
Operator
eUnit_Db
Global Unit group 3 for
dB
unitless
RW
4
INT32
506
Operator
eUnit_Dens Global Unit group 4 for
Density
unitless
RW
4
INT32
508
Operator
eUnit_Diam Global Unit group 5 for
Dimension
unitless
RW
4
INT32
50A
Operator
eUnit_Hz
Global Unit group 6 for
Hz
unitless
RW
4
INT32
50C
Operator
eUnit_Kv
Global Unit group 7 for
Viscosity
unitless
RW
4
INT32
50E
Operator
eUnit_mA
Global Unit group 8 for
mA
unitless
RW
4
INT32
510
Operator
eUnit_Mass Global Unit group 9 for
Mass
unitless
RW
4
INT32
512
Operator
eUnit_MS
Global Unit group 10 for
Milli Second
unitless
RW
4
INT32
Содержание PanaFlow XMT1000
Страница 1: ...GE Oil Gas Flow 910 313 Rev A June 2017 PanaFlow XMT1000 User s Manual ...
Страница 2: ......
Страница 4: ...ii no content intended for this page ...
Страница 8: ...Contents vi PanaFlow XMT1000 User s Manual no content intended for this page ...
Страница 12: ...Preface x PanaFlow XMT1000 User s Manual no content intended for this page ...
Страница 42: ...Chapter 3 Error Codes and Troubleshooting 30 PanaFlow XMT1000 User s Manual no content intended for this page ...
Страница 46: ...34 PanaFlow XMT1000 User s Manual no content intended for this page ...
Страница 68: ...Appendix C HART Communication 56 PanaFlow XMT1000 User s Manual no content intended for this page ...
Страница 95: ......