Touchpad programming

To program the touchpad, do the following:
1.

Press 

and enter the function number to select the desired 

function. 

Table 4

 lists the programming information for 

each function.

Note:  

Press 

*

 repeatedly to scroll through available 

functions.

2.

To exit the function menu, press 

#.

Adjust touchpad tone (0)

To raise or lower the tone on the touchpad, do the following:
1.

Enter 

* 0

.

2.

Press   or    to raise or lower the tone. The touchpad will 
emit a continuous tone, allowing you to hear the selection.

3.

To save the tone and exit, press 

#

.

Temporary master mode (1)

The master mode of operation allows you to temporarily access 
any partition (providing your code is authorized) within the 

system and to do functions in other partitions. The keypad will 
revert back to its assigned partition 60 seconds after a key press, 
or 10 seconds without a keypress. To set a temporary master 

mode, do the following:
1.

Enter 

* 1

.

2.

Enter your user code. 

3.

To exit, press

 #

.

View zone status ( )

To view zone status, do the following:
1.

Press 

*

  .

2.

Press   or   to scroll through the list. The list shows all 
zones in sequential order by zone number.

3.

To exit, press

 #

.

Service menu (2)

Service Required

 message will display periodically if the 

system requires service. To access the service menu, do the 

following:
1.

Enter 

* 2

 to display one or more of the fault messages in 

Table 9 

on page 8.

2.

Press   or   to scroll through the messages. 

3.

To exit the service messages, press

 # #

.

View alarm memory (3)

To view alarm memory, do the following:
1.

Enter 

* 3

.

2.

Press   or   to display the alarm memory list in sequential 
order by zone number.

3.

To exit, press 

#

.

Test function (44)

If programmed, the test function will do a battery test, communi-

cator test, and/or a siren test. No alarms will be sent. To test the 
system, do the following:
1.

Enter 

* 44

2.

To exit, press 

#

.

Display test function (45)

To test display functions, do the following:
1.

Enter 

* 45

. All display pixels and LED indicators will flash, 

but no alarms will be sent.

2.

To exit, press #.

Table 4.

Touchpad functions

Function Number

Function

0

Adjust touchpad tone

1

Temp master mode

View zone status

2

Service  menu

3

View alarm memory

44

Test function

45

Display function

46

Light control for X10

47

House codes for X10

49

Change languages

5

Change user codes

6

Assign user authority

7

Reset  function

90

Log review

91

Adjust view/brightness of LCD

92

Program custom messages

93

Set touchpad options

94

Set touchpad number and partition

95

Set elapsed time (in minutes) since last 

autotest

97

Set system time and date

98

Call back for download

99

Seize phone line for download

Chime Walk 

test

Exit

Silent exit

Содержание NX-148E-RF - Security NetworX NX-8E System

Страница 1: ... Phillips screwdriver Drill 15 64 in drill bit Mounting screws provided Wall anchors optional 4 conductor 22 18 16 14 or 12 gauge wire see Table 1 on page 2 Installation To install the touchpad do the following 1 Remove the mounting plate screw Figure 1 from the bottom of the touchpad and lift off the mounting plate 2 At the mounting location use the mounting plate to mark the location for the ant...

Страница 2: ...t overlap any blocks of 8 zones All other control panels can have wireless zones added to any zone If a hardwire input on either the control panel or hardwire expander is also present on the same zone as an enabled wireless zone the wireless transmitter takes priority Program settings When programming wireless transmitters into the touchpad there are various options and partitions you can set for ...

Страница 3: ...irmation 9 To program remaining transmitters repeat steps 6 to 8 10 To exit program mode press EXIT EXIT Table 2 Device numbers Partition Touchpad 1 2 3 4 5 6 7 8 1 192 193 194 195 196 197 198 199 2 200 201 202 203 204 205 206 207 3 208 209 210 211 212 213 214 215 4 216 217 218 219 220 221 222 223 5 224 225 226 227 228 229 230 231 6 232 233 234 235 236 237 238 239 7 240 241 242 243 244 245 246 247...

Страница 4: ...l supervision time to 256 hours 6 Enter the new fire supervision time 0 to 255 and press If you enter 0 it will set the fire supervision window to 256 hours 7 Enter the new short supervision time up to 30 minutes The short supervision setting prevents arming if a trans mitter has not checked in within the set time This applies only to specific countries outside the U S Check the control panel inst...

Страница 5: ...if the system requires service To access the service menu do the following 1 Enter 2 to display one or more of the fault messages in Table 9 on page 8 2 Press or to scroll through the messages 3 To exit the service messages press View alarm memory 3 To view alarm memory do the following 1 Enter 3 2 Press or to display the alarm memory list in sequential order by zone number 3 To exit press Test fu...

Страница 6: ... Enter 6 2 Enter your master code 3 Enter the user number 4 Use keys 1 yes and 0 no to assign authorities when prompted or press to move to the next prompt 5 Assign the partitions for the user 6 To return to step 3 and program another user code press 7 To exit press Note Retain at least one code with access rights to all partitions to allow adding future users Reset function 7 The system must be d...

Страница 7: ...Enter your program code 3 Enter the elapsed time in minutes using three digits For example enter 005 for 5 minutes 4 To exit press Set system time and date 97 To set the system time and date do the following 1 Enter 97 2 Enter your program code 3 Press or to scroll for the proper hour 4 Press to advance to the next selection minutes 5 Repeat steps 3 and 4 until the time and date are set 6 To exit ...

Страница 8: ...s not operating properly Control fail to comm The control made an unsuccessful attempt to communicate a message to the central station Control ground fault A short to ground has been detected on a control circuit Control loss of time Your system has lost total power and needs the clock reset Control power trouble The main power to the system is off Control low battery The standby battery is low Ex...

Страница 9: ...tor test at a specified interval Start Prog Start programming Local Programming has started End Prog End programming Local programming has ended Start Dnld Start download Download session has started End Dnld End download Download session has ended Cancel Cancel was initiated within 5 minutes of an alarm Gnd Flt Ground fault A short to ground has been detected Man Test Manual test Bell and or comm...

Страница 10: ...eyfob Partition 5 keyfob Partition 6 keyfob Partition 7 keyfob Partition 8 keyfob Zone _____ Assigned to module _____ RM HE P 1 Enable sensor 2 Supervised 3 Fire supervision 4 Input option 1 5 Input option 2 _ 6 8 Not used Partition 1 keyfob Partition 2 keyfob Partition 3 keyfob Partition 4 keyfob Partition 5 keyfob Partition 6 keyfob Partition 7 keyfob Partition 8 keyfob Zone _____ Assigned to mo...

Страница 11: ... keyfob Partition 8 keyfob Table 11 Module programming settings continued Location Segment 1 Segment 2 Zone _____ Assigned to module _____ RM HE P 1 Enable sensor 2 Supervised 3 Fire supervision 4 Input option 1 5 Input option 2 _ 6 8 Not used Partition 1 keyfob Partition 2 keyfob Partition 3 keyfob Partition 4 keyfob Partition 5 keyfob Partition 6 keyfob Partition 7 keyfob Partition 8 keyfob Zone...

Страница 12: ...b Partition 6 keyfob Partition 7 keyfob Partition 8 keyfob Table 11 Module programming settings continued Location Segment 1 Segment 2 Zone _____ Assigned to module _____ RM HE P 1 Enable sensor 2 Supervised 3 Fire supervision 4 Input option 1 5 Input option 2 _ 6 8 Not used Partition 1 keyfob Partition 2 keyfob Partition 3 keyfob Partition 4 keyfob Partition 5 keyfob Partition 6 keyfob Partition ...

Страница 13: ...E P 1 Enable sensor 2 Supervised 3 Fire supervision 4 Input option 1 5 Input option 2 _ 6 8 Not used Partition 1 keyfob Partition 2 keyfob Partition 3 keyfob Partition 4 keyfob Partition 5 keyfob Partition 6 keyfob Partition 7 keyfob Partition 8 keyfob Zone _____ Assigned to module _____ RM HE P 1 Enable sensor 2 Supervised 3 Fire supervision 4 Input option 1 5 Input option 2 _ 6 8 Not used Partit...

Страница 14: ...ce could void the user s authority to operate the equip ment Panel Compatibility compatible with all NetworX control panels except CF commercial fire panels Frequency 319 5 MHz Wireless range 600 feet 183 m open air Power Requirements 12 0 VDC provided by panel Current Draw 75 mA maximum Operating Temperature 32 to 120 F 0 to 49 C Storage Temperature 30 to 140 F 34 to 60 C Humidity 90 relative non...

Отзывы: