Set touchpad number and partition (94)

To set the touchpad number and partition, do the following:
1.

Enter 

* 94

2.

Enter your program code. 

3.

Enter the touchpad number (see 

Table 2

) and press 

*

4.

Enter the partition number and press 

*.

5.

To exit, press #.

Add transmitters 

To add transmitters to the touchpad receiver, do the following:
1.

Enter 

* 8

 at the touchpad.

2.

Enter your program code (factory default is 9 7 1 3).

3.

Enter the device number (

Table 2

) and press 

#.

4.

To load factory defaults and clear unwanted information in 
memory for new installations, enter 

9 1 0 #

.

5.

To determine the starting zone number for the specific 

touchpad receiver on new installations, set the receiver zone 
bank (Location 594) The bank setting is based on the zone 
capabilities of both the receiver and the panel and must be 

set before you add (learn) transmitters.

6.

Enter 

400 #

 to enter the sensor (transmitter) learning location.

7.

Enter a zone number 

(

1 to 192) and press 

*

. Three beeps 

from the touchpad indicates an entry error. This occurs if 
you enter a transmitter number that is not within the 

receiver’s zone block or if you try to learn a transmitter that 
is already learned into the receiver.

Note:  

If you change your mind about your entry, enter 

400 

# 0*

 to terminate programming and start over from 

step 6.

8.

Trip the desired transmitter (within 250 seconds) as described 

in 

Table 3

. Listen for the 

ding dong

 for confirmation.

9.

To program remaining transmitters, repeat steps 6 to 8.

10. To exit program mode, press 

EXIT EXIT

.

Table 2.

Device numbers

Partition

Touchpad

1

2

3

4

5

6

7

8

1

192

193

194

195

196

197

198

199

2

200

201

202

203

204

205

206

207

3

208

209

210

211

212

213

214

215

4

216

217

218

219

220

221

222

223

5

224

225

226

227

228

229

230

231

6

232

233

234

235

236

237

238

239

7

240

241

242

243

244

245

246

247

8

248

249

250

251

252

253

254

255

Table 3.

Tripping transmitters

Transmitter

Action

Door/window, shock, glass 

guard, freeze, UFT 

Activate tamper switch by removing cover.

Door/window with external 

contact

Activate tamper switch by removing cover. 

Feature 4—Input option 1, must be on.

Recessed door/window

Activate tamper switch by removing circuit 

board until tamper switch is exposed.

Micro door/window and
Micro recessed door/window

Refer to the installation instructions for the 

specific sensor for activation information.

SlimLine door/window

Remove cover, then press the button on 

the top of the sensor, or activate the 

tamper switch by removing the cover.

PIR

Refer to the installation instructions for the 

specific sensor for activation information.

Smoke detector without 

tamper switch

Press and hold the test button.

Smoke detector with tamper 

switch

Trip the tamper switch. 

Feature 4—Input 

option 1, must be on.

Heat detector

Press, then release the tamper switch.

Single button panic

Press and hold the button.

Dual button panic

Press and hold both buttons together.

Keyfobs

Press and hold the arm and disarm 

buttons together.

Repeater

Press, then release the tamper switch.

Содержание NX-148E-RF - Security NetworX NX-8E System

Страница 1: ... Phillips screwdriver Drill 15 64 in drill bit Mounting screws provided Wall anchors optional 4 conductor 22 18 16 14 or 12 gauge wire see Table 1 on page 2 Installation To install the touchpad do the following 1 Remove the mounting plate screw Figure 1 from the bottom of the touchpad and lift off the mounting plate 2 At the mounting location use the mounting plate to mark the location for the ant...

Страница 2: ...t overlap any blocks of 8 zones All other control panels can have wireless zones added to any zone If a hardwire input on either the control panel or hardwire expander is also present on the same zone as an enabled wireless zone the wireless transmitter takes priority Program settings When programming wireless transmitters into the touchpad there are various options and partitions you can set for ...

Страница 3: ...irmation 9 To program remaining transmitters repeat steps 6 to 8 10 To exit program mode press EXIT EXIT Table 2 Device numbers Partition Touchpad 1 2 3 4 5 6 7 8 1 192 193 194 195 196 197 198 199 2 200 201 202 203 204 205 206 207 3 208 209 210 211 212 213 214 215 4 216 217 218 219 220 221 222 223 5 224 225 226 227 228 229 230 231 6 232 233 234 235 236 237 238 239 7 240 241 242 243 244 245 246 247...

Страница 4: ...l supervision time to 256 hours 6 Enter the new fire supervision time 0 to 255 and press If you enter 0 it will set the fire supervision window to 256 hours 7 Enter the new short supervision time up to 30 minutes The short supervision setting prevents arming if a trans mitter has not checked in within the set time This applies only to specific countries outside the U S Check the control panel inst...

Страница 5: ...if the system requires service To access the service menu do the following 1 Enter 2 to display one or more of the fault messages in Table 9 on page 8 2 Press or to scroll through the messages 3 To exit the service messages press View alarm memory 3 To view alarm memory do the following 1 Enter 3 2 Press or to display the alarm memory list in sequential order by zone number 3 To exit press Test fu...

Страница 6: ... Enter 6 2 Enter your master code 3 Enter the user number 4 Use keys 1 yes and 0 no to assign authorities when prompted or press to move to the next prompt 5 Assign the partitions for the user 6 To return to step 3 and program another user code press 7 To exit press Note Retain at least one code with access rights to all partitions to allow adding future users Reset function 7 The system must be d...

Страница 7: ...Enter your program code 3 Enter the elapsed time in minutes using three digits For example enter 005 for 5 minutes 4 To exit press Set system time and date 97 To set the system time and date do the following 1 Enter 97 2 Enter your program code 3 Press or to scroll for the proper hour 4 Press to advance to the next selection minutes 5 Repeat steps 3 and 4 until the time and date are set 6 To exit ...

Страница 8: ...s not operating properly Control fail to comm The control made an unsuccessful attempt to communicate a message to the central station Control ground fault A short to ground has been detected on a control circuit Control loss of time Your system has lost total power and needs the clock reset Control power trouble The main power to the system is off Control low battery The standby battery is low Ex...

Страница 9: ...tor test at a specified interval Start Prog Start programming Local Programming has started End Prog End programming Local programming has ended Start Dnld Start download Download session has started End Dnld End download Download session has ended Cancel Cancel was initiated within 5 minutes of an alarm Gnd Flt Ground fault A short to ground has been detected Man Test Manual test Bell and or comm...

Страница 10: ...eyfob Partition 5 keyfob Partition 6 keyfob Partition 7 keyfob Partition 8 keyfob Zone _____ Assigned to module _____ RM HE P 1 Enable sensor 2 Supervised 3 Fire supervision 4 Input option 1 5 Input option 2 _ 6 8 Not used Partition 1 keyfob Partition 2 keyfob Partition 3 keyfob Partition 4 keyfob Partition 5 keyfob Partition 6 keyfob Partition 7 keyfob Partition 8 keyfob Zone _____ Assigned to mo...

Страница 11: ... keyfob Partition 8 keyfob Table 11 Module programming settings continued Location Segment 1 Segment 2 Zone _____ Assigned to module _____ RM HE P 1 Enable sensor 2 Supervised 3 Fire supervision 4 Input option 1 5 Input option 2 _ 6 8 Not used Partition 1 keyfob Partition 2 keyfob Partition 3 keyfob Partition 4 keyfob Partition 5 keyfob Partition 6 keyfob Partition 7 keyfob Partition 8 keyfob Zone...

Страница 12: ...b Partition 6 keyfob Partition 7 keyfob Partition 8 keyfob Table 11 Module programming settings continued Location Segment 1 Segment 2 Zone _____ Assigned to module _____ RM HE P 1 Enable sensor 2 Supervised 3 Fire supervision 4 Input option 1 5 Input option 2 _ 6 8 Not used Partition 1 keyfob Partition 2 keyfob Partition 3 keyfob Partition 4 keyfob Partition 5 keyfob Partition 6 keyfob Partition ...

Страница 13: ...E P 1 Enable sensor 2 Supervised 3 Fire supervision 4 Input option 1 5 Input option 2 _ 6 8 Not used Partition 1 keyfob Partition 2 keyfob Partition 3 keyfob Partition 4 keyfob Partition 5 keyfob Partition 6 keyfob Partition 7 keyfob Partition 8 keyfob Zone _____ Assigned to module _____ RM HE P 1 Enable sensor 2 Supervised 3 Fire supervision 4 Input option 1 5 Input option 2 _ 6 8 Not used Partit...

Страница 14: ...ce could void the user s authority to operate the equip ment Panel Compatibility compatible with all NetworX control panels except CF commercial fire panels Frequency 319 5 MHz Wireless range 600 feet 183 m open air Power Requirements 12 0 VDC provided by panel Current Draw 75 mA maximum Operating Temperature 32 to 120 F 0 to 49 C Storage Temperature 30 to 140 F 34 to 60 C Humidity 90 relative non...

Отзывы: