Possible Log Messages 

Display 

Description 

Txlobat 

Transmitter Low Battery - The transmitter has a low battery. 

ZN Lost 

Zone Lost - A wireless or multiplexed zone device is not reporting to the control. 

Duress 

Duress - The control has been armed or disarmed with a duress code. 

Man Fire 

Manual Fire - Code pad ‘Fire’ has been activated. 

Aux 2 

Auxiliary 2 - Code pad ‘Medical’ has been activated. 

Panic 

Panic - Code pad ‘Panic’ has been activated. 

KP Tamper 

Code pad Tamper - The code pad tamper has been activated. 

BoxTamp 

Box Tamper - The box tamper circuit has been activated. 

AC Fail 

AC Fail - AC failure has been detected. 

OverCur 

Over Current - A short circuit of a power supply has occurred. 

Srn Tamp 

Siren Tamper - A siren or speaker tamper has been detected. 

Tel Flt 

Telephone Fault - A telephone fault or tamper has been detected. 

Exp Trb 

Expansion Trouble - An expansion device or code pad is not reporting to the 
control panel. 

Log Full 

Log Full - The event log is full. 

Open 

Open - Reports user number, date, time and area of opening. 

Close 

Close - Reports user number, date, time and area of closing. 

Exit Err 

Exit Error - Entry/Exit zone was faulted at the instant the exit delay expired. 

Rec Close 

Recent Close - An alarm occurred within 5 minutes after the control was armed. 

Autotest 

Auto Test - Sending a communicator test at a specified interval. 

Start Prog 

Start Programming - Local programming is started. 

End Prog 

End Programming - Local programming is ended. 

Start Dnld 

Start Download - Download session is started. 

End Dnld 

End Download - Download session is ended. 

Cancel 

Cancel - System is disarmed; Cancel was initiated within 5 minutes of an alarm. 

Gnd Flt 

Reserved.  

Man Test 

Manual Test - Bell and/or communicator test while system is in disarmed condition. 

Re-exit 

Re-Exit - The exit delay has been re-started without disarming the system. 

Output Trip 

Output Trip - A trip has occurred on an expander auxiliary output. 

Data Lost 

Data Lost - Communication of a signal has failed (log only event). 

Walk-test 

Walk-Test - A zone ‘Walk-Test’ mode has been activated. 

End Test 

End Test - Test has been ended. 

Cross-Trip 

Cross Trip - The first zone of a cross zone has been tripped (log only event). 

Expansion Event  Expansion Event - An expansion module has created an undefined event. 
Partial Arm 

Partial Arm - Reports a closing in the stay mode. 

Listen In 

Listen In - A listen in function has been activated. 

Service Start 

Service Start - Technician is on site. 

Service End 

Service End - Technician is off site. 

Code Entry 

Code Entry - A code has been entered. 

First Open 

First Open - Reports when the first area is disarmed. 

Last Close 

Last Close - Reports when the last area is armed. 

Sprnklr 

Sprinkler - Instant sprinkler supervisory report 

Clock Set 

Clock Set - Clock has been reset. 

RF Jammed 

RF Jammed - A wireless expansion module is jammed by another RF device 

CleanMe 

Clean Me - A smoke detector requires cleaning. 

Содержание NetworX Series

Страница 1: ...NetworX Series NX 148E LCD Code pad Installation and Setup Manual Australian New Zealand version...

Страница 2: ...part nor shall its contents be disclosed to any third party without prior written approval of GE Interlogix Australia Please refer to the current GE Interlogix product catalogue for detailed warranty...

Страница 3: ...Set Elapsed Time in Minutes Since Last Autotest 13 7c Set System Time and Date 13 7d Adjust Code Pad Tone 13 7e View Zone Status 14 7f View Alarm Memory 14 7g Test Function 14 7h Display Test Function...

Страница 4: ...pound hash key If the feature entered is a valid feature the top line of the LCD screen will display the feature number on the left and the segment number on the right The bottom line of the display...

Страница 5: ...s used to enter LCD text when programming Refer to feature on page 8 for custom messages Custom zone descriptions and messages are stored character or ASCII data type This information is programmed us...

Страница 6: ...ROOM SOUTH WEST BACK DOWN HALL MASTER RUMPUS STAIRS WINDOW BATHROOM DURESS HEAT MICROWAVE SAFE STORAGE WING BEAM EAST HOLDUP MOTION SENSOR STUDY WIRELESS BEDROOM EMERGENCY HOUSE NORTH SHOCK TAMPER YA...

Страница 7: ...will be displayed 6 Programming the Code Pads This section describes how to program the address and area of each code pad as well as the available options The code pad address allows the control panel...

Страница 8: ...ownload 17 Changing user codes 16 Chime Walk Test 17 Assigning user authority 16 Exit Silent Exit 17 6b Adjusting the LCD Contrast Brightness Action Result Prompts to Please Enter Your Code master cod...

Страница 9: ...u to enter message number followed by Zones 1 through 192 custom messages are message numbers 1 192 respectively For example For zone 1 description will read press for zone 6 press Message 193 Custom...

Страница 10: ...ble key press silence option Silences the pulsing code pad sounder for 5 seconds when a key is pressed 5 Armed Zone Info Enable armed zone information If on the LCD code pad will display faulted or by...

Страница 11: ...log that can be retrieved using a master code This log contains a listing of the last 185 events along with date time and area where the event occurred Action Result Prompts to Please Enter Your Code...

Страница 12: ...at a specified interval Start Prog Start Programming Local programming is started End Prog End Programming Local programming is ended Start Dnld Start Download Download session is started End Dnld End...

Страница 13: ...ease Enter Your Code master code Displays date and time with the current hour flashing or Scroll to select the current hour Advances to the selection for the minutes Repeat the last two steps until th...

Страница 14: ...View Alarm Memory Action Result Displays the zone descriptions or Displays the alarm memory list in sequential order by zone number Exits the mode 7g Test Function Action Result Test will be performe...

Страница 15: ...vices have been programmed Exits the function 7j House Codes for X 10 Devices When used in conjunction with an X 10 output device such as the NetworX NX 507E NX 508E NX 534E or NX 540E this menu allow...

Страница 16: ...another user code needs to be programmed Code pad will beep 3 times if code is rejected while display is prompting for a user number Exits and saves data 7m Assigning Authority Level You must have au...

Страница 17: ...beeping the reset did not execute properly Enter your code to silence the code pad Wait a few minutes and repeat step 2 to attempt another reset 7o Other Functions When using or a valid user code may...

Страница 18: ...imary power is connected to the NX control panel It will flash if the system has a low standby battery condition On will illuminate if any area is fully armed Chime will illuminate if any area is in t...

Страница 19: ...mple if area 4 is armed will disarm area 4 If area 4 is disarmed will arm it To control the individual areas refer to the following section Operating Individual Areas in the Multi Area Mode Operating...

Страница 20: ...selected 8e Bypass in the Multi Area Mode If you wish to bypass one or more zones this must be done while the system is in the disarmed state Action Result Prompts Please Enter Your Code user code Pro...

Страница 21: ...ell or siren circuit Control Box Tamper Optional The control panel s box tamper has been activated Control Phone Trouble The phone line connected to the control is not operating properly Control Fail...

Страница 22: ...uble An expansion device or code pad is not reporting to the control panel Expansion Siren trouble An expansion device has detected some form of trouble on the bell or siren circuit Zone Tamper Press...

Страница 23: ...06 207 3 208 209 210 211 212 213 214 215 4 216 217 218 219 220 221 222 223 5 224 225 226 227 228 229 230 231 6 232 233 234 235 236 237 238 239 7 240 241 242 243 244 245 246 247 8 248 249 250 251 252 2...

Страница 24: ...cham Victoria 3132 Tel 03 9259 4700 Fax 03 9259 4799 www gesecurity com au NX is distributed in Australia and New Zealand by NSW DAS Alexandria VIC DAS Coburg SA DAS Edwardstown Tel 02 9698 9698 Tel 0...

Отзывы: