![GE NetworX Series Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/ge/networx-series/networx-series_installation-and-setup-manual_4059216012.webp)
NX-148E LCD Code Pad Installation and Setup Manual
12
Possible Log Messages
Display
Description
Txlobat
Transmitter Low Battery - The transmitter has a low battery.
ZN Lost
Zone Lost - A wireless or multiplexed zone device is not reporting to the control.
Duress
Duress - The control has been armed or disarmed with a duress code.
Man Fire
Manual Fire - Code pad ‘Fire’ has been activated.
Aux 2
Auxiliary 2 - Code pad ‘Medical’ has been activated.
Panic
Panic - Code pad ‘Panic’ has been activated.
KP Tamper
Code pad Tamper - The code pad tamper has been activated.
BoxTamp
Box Tamper - The box tamper circuit has been activated.
AC Fail
AC Fail - AC failure has been detected.
OverCur
Over Current - A short circuit of a power supply has occurred.
Srn Tamp
Siren Tamper - A siren or speaker tamper has been detected.
Tel Flt
Telephone Fault - A telephone fault or tamper has been detected.
Exp Trb
Expansion Trouble - An expansion device or code pad is not reporting to the
control panel.
Log Full
Log Full - The event log is full.
Open
Open - Reports user number, date, time and area of opening.
Close
Close - Reports user number, date, time and area of closing.
Exit Err
Exit Error - Entry/Exit zone was faulted at the instant the exit delay expired.
Rec Close
Recent Close - An alarm occurred within 5 minutes after the control was armed.
Autotest
Auto Test - Sending a communicator test at a specified interval.
Start Prog
Start Programming - Local programming is started.
End Prog
End Programming - Local programming is ended.
Start Dnld
Start Download - Download session is started.
End Dnld
End Download - Download session is ended.
Cancel
Cancel - System is disarmed; Cancel was initiated within 5 minutes of an alarm.
Gnd Flt
Reserved.
Man Test
Manual Test - Bell and/or communicator test while system is in disarmed condition.
Re-exit
Re-Exit - The exit delay has been re-started without disarming the system.
Output Trip
Output Trip - A trip has occurred on an expander auxiliary output.
Data Lost
Data Lost - Communication of a signal has failed (log only event).
Walk-test
Walk-Test - A zone ‘Walk-Test’ mode has been activated.
End Test
End Test - Test has been ended.
Cross-Trip
Cross Trip - The first zone of a cross zone has been tripped (log only event).
Expansion Event Expansion Event - An expansion module has created an undefined event.
Partial Arm
Partial Arm - Reports a closing in the stay mode.
Listen In
Listen In - A listen in function has been activated.
Service Start
Service Start - Technician is on site.
Service End
Service End - Technician is off site.
Code Entry
Code Entry - A code has been entered.
First Open
First Open - Reports when the first area is disarmed.
Last Close
Last Close - Reports when the last area is armed.
Sprnklr
Sprinkler - Instant sprinkler supervisory report
Clock Set
Clock Set - Clock has been reset.
RF Jammed
RF Jammed - A wireless expansion module is jammed by another RF device
CleanMe
Clean Me - A smoke detector requires cleaning.