4
Step
Test for
Leaks
WARNING
TEST FOR LEAKS
A complete gas tightness check must be
performed at the installation site. DO NOT
USE A FLAME TO CHECK FOR GAS
LEAKS.
• Do not use the burner until all connections
have been leak tested.
• Repeat leak test after each LP tank change or
gas re-connect.
• Check to be sure the main valve on the LP
tank or the shut-off valve is in the “OFF”
position.
• Make a soap solution of one part liquid
detergent and one part water.
The valve panel must be removed to check
the valves and fittings.
• All control valves should be in the “OFF”
position.
• Remove the knobs.
• Remove the 4 screws holding the valve panel
to the burner.
• Pull the panel outwards and unplug the wire
from the back of the rotary igniter.
TO TEST:
• Apply the soap solution around all
connections, valve and tubing.
• Turn the gas supply on.
• Check all connections from the supply line
or LP tank up to and including the manifold
pipe assembly.
• If a leak is detected, turn gas supply off and
tighten fittings. Turn the gas on and check
again.
• To re-install the valve panel, re-connect the
igniter wire and secure the panel with
original screws.
TO MATCH LIGHT:
• Remove the burner grate.
• Strike match and hold adjacent to burner
port.
• Push and turn the control knob to “LITE”.
• Rotate the control knob to desired setting.
• Replace grate.
ALWAYS TURN GAS SUPPLY OFF AT THE
SHUT-OFF VALVE OR LP TANK WHEN
NOT IN USE.
5
Step
Lighting
the Burner
WARNING
Do not attempt to light
the burner if the odor of gas is present.
CAUTION: Keep hands and face as far away
from the burner as possible when lighting.
• Remove burner cover.
• Turn all knobs to “OFF” position.
• Turn gas supply on at the LP tank or shut-off
valve.
NOTE: When lighting the burner for the first
time or after a LP tank change, up to 20
seconds may be required to purge air from
the lines.
• Push and turn control knob
counter-clockwise
to “LITE” position, turn the small igniter
knob next to the burner knob
clockwise.
NOTE: The spark will produce a snapping
sound. This is normal.
• If the burner does not light within 4 seconds,
turn knobs to “OFF and wait 5 minutes for
the gas to dissipate before trying again.
• If the burner does not light after several
attempts, the burner can be lit with a match.