– 17 –
Fan Motor Assembly
The fan motor assembly is located inside the fan
motor housing above the canopy. The fan motor
has 4 speeds and utilizes a start/run capacitor. Fan
speeds are selected at the push-button assembly
located in the visor.
To remove the fan motor assembly:
Caution:
This procedure requires that the cooking
unit below the hood be protected from any possible
damage.
1. Disconnect power to the vent hood.
2. Remove the visor. (See
Visor.
)
3. Remove the light shield. (See
Light Receptacle.
)
4. Remove the duct cover. (See
Duct Cover
.)
5. Remove the power supply housing cover. (See
Power Supply Housing
.
)
6. Remove the 4 Phillips-head screws that hold
the lower electrical component cover in place.
Remove the cover.
7. Remove the bottom wire retention clamp.
8. Disconnect the push-button assembly ribbon
connector from the power control board.
9. Unplug the fan motor wiring connector from
the power control board. Remove the fan motor
ground wire.
10. Remove the 4 Phillips-head screws that hold the
inner bracket to the canopy. Lower the inner
bracket.
11. Remove light wiring and split-ring grommets
from inner bracket.
Inner Bracket
Fan Motor
Ground Wire
Ribbon
Wire Retention Clamp
(
Continued Next Page
)