background image

24"

 

(61)

1 9/16"

(3.97)

3 1/8"

(7.93)

35 1/2"

 

(90.2)

2 5/16"

(5.874)

7/16"

 (1.1)

Trim overlap

3 1/2"

(8.9)

75"

(190.5 )

From floor

to bottom

of electrical

area

*84 1/2"

(214.6)

*Trim will overlap

additional 7/16"

6"

(15.24)

10"

(25.4)

ELEC.

SIDE VIEW

FRONT VIEW

TOP VIEW

W

STANDARD INSTALLATION

ZIC360NHLH_RH

WATER

5"

(12.7)

5"

(12.7)

3 1/2"

(9.0)

3 1/2"

(8.9)

NOTES

STANDARD INSTALLATION

Product Specification Created 7/14

ZIC360NHLH

GE Monogram

®

 36" Built-In Bottom-freezer Refrigerator

A   Mounting the junction 

box in this location will 

also allow for front 

accessability through 

access panel.

B   Water supply area.

 WARNING:

The refrigerator is top 

heavy and must be secured 

to prevent the possibility of 

tipping forward.  Failure to 

do so may result in death 

or serious injury.
The information below is 

for cabinet design only.  

When installing the anti-

tip system you must use 

the product installation 

instructions.

The information below 

applies to all installation 

constructions:
•  A wall bracket, bolts and 

toggles will be supplied 

with the unit.

•  The bolts will be used to 

attach bracket to wall in 

4 locations. Two of the 

locations must penetrate 

the center of the wall 

studs.

•  The toggles are used for 

stability in drywall and 

when metal studs are 

encountered. Lag bolts 

are used in wood studs.

•  In installation opening, 

measure 81 ½” from  

floor and draw a 

horizontal line.

•  Locate and mark the wall 

studs on horizontal line.  

Verify at least two studs 

have their centerlines 

within the center 32.5” 

of installation opening to 

ensure 2 wall studs are 

penetrated.

•  The bracket will be 

centered left to right in 

opening with bottom of 

bracket on the horizontal 

line.

•  When unit is placed in 

opening, the bracket tabs 

will align with openings 

in back of the unit.  The 

unit will be secured to the 

bracket using supplied 

“L” bolts.

See Installation 

Instructions for detailed 

instructions.

A

STANDARD INSTALLATION

ANTI-TIP BRACKET

24"

 

(61.0)

1 1/2"

(3.8)

3"

(7.6)

7/16"

 (1.1)

Trim overlap

35 1/2"

 

(90.2)

2 5/16"

(5.9)

SIDE VIEW

FRONT VIEW

ZIC360NXRH

*83 1/2" min

*84 1/2" max

(212.1-214.6)

*Trim will overlap

additional 7/16"

3 1/2"

(8.9)

75"

(190.5 )

From floor

to bottom

of electrical

area

ELEC.

6"

(15.2)

10"

(25.4)

SIDE VIEW INSTALLED

WITH ANTI-TIP BRACKET

81 1/2"

(207.0)

WATER

5"

(12.7)

5"

(12.7)

3 1/2"

(9.0)

WATER

10" 

(25.4)

Use two 

additional hole 

locations at end 

of brackets

Wall

Studs

Bracket 

mounted

into vertical 

wall studs

centered

within the

cutout

C

Ensure holes

selected are

centered on

the studs

L

FRONT VIEW OF CUTOUT

WITH ANTI-TIP BRACKET

Содержание Monogram ZIC360NHLH

Страница 1: ...SECTION 1 Product Specification Created 7 14 ZIC360NHLH GE Monogram 36 Built In Bottom freezer Refrigerator SECTION 2 1 4 FRAMED PANELS 3 4 OVERLAY PANELS FLUSH INSET INSTALLATION STANDARD INSTALLATION ...

Страница 2: ...idth 39 99 1 cm Cutout Height 84 1 2 214 6 cm Cutout Depth 26 3 16 66 5 cm Plumbing Requirements 1 4 OD copper tubing or GE SmartConnect kit Shipping Weight 640 lb 290 3 kg 38 96 5 9 5 8 24 4 20 5 8 52 4 25 7 8 65 7 83 1 2 212 1 73 1 4 186 1 26 66 0 3 3 8 8 6 3 3 8 8 6 SIDE VIEW FRONT VIEW 83 1 2 212 1 35 89 0 Case width 38 3 4 98 4 TOP VIEW ZIC360NHLH Allow 4 10 2 min clearance to a wall for 90 d...

Страница 3: ...the bracket tabs will align with openings in back of the unit The unit will be secured to the bracket using supplied L bolts See Installation Instructions for detailed instructions FLUSH INSTALLATION ZIC360NHLH_RH 39 99 1 Flush inset width 37 1 2 95 3 Width between cleats 3 4 1 9 Width of side cleats 5 1 4 13 3 1 2 1 3 26 3 16 66 5 Flush inset depth 20 15 16 53 2 Depth to cleat FRONT VIEW SIDE VIE...

Страница 4: ...nified grille kit for dual installation Maximum total panel weight 25 lbs FLUSH INSET INSTALLATION Product Specification Created 7 14 ZIC360NHLH GE Monogram 36 Built In Bottom freezer Refrigerator Grille Panel Fresh Food Panel Freezer Drawer Panel A B C D X ROUTER 1 4 DEEP HINGE CLEARANCES Y Z Grille Panel Fresh Food Panel Freezer Drawer Panel A Fresh Food Panel Freezer Drawer Panel E B C D A B C ...

Страница 5: ... 5 1 2 13 9 9 22 9 84 1 2 214 6 Finished Opening 3 1 2 8 9 W FRONT VIEW ELEC 5 1 2 13 9 9 22 9 3 1 2 8 9 25 63 5 min To wall 25 63 5 min To wall 1 1 2 3 8 130 Door swing 130 Door swing 75 1 2 191 8 From floor to bottom of electrical area ELEC SIDE VIEW 7 17 8 7 17 8 WATER 3 1 2 9 0 WATER 3 1 2 9 0 5 3 4 14 6 5 3 4 14 6 ZIC360NHLH_ZIC360NHRH 75 1 2 191 8 Finished Width 26 3 16 66 5 Min Cutout Depth...

Страница 6: ... Shipping height Use leveling legs and wheels for maximum 1 height adjustment from shipping height Allow 4 10 2 min clearance to a wall for 90 door swing These refrigerators are equipped with a 2 position door stop The factory set 130 door swing can be adjusted to 90 if clearances to adjacent cabinets or walls is restricted Allow a 15 minimum clearance to wall for pan removal If the 90 door stop p...

Страница 7: ...ll studs The toggles are used for stability in drywall and when metal studs are encountered Lag bolts are used in wood studs In installation opening measure 81 from floor and draw a horizontal line Locate and mark the wall studs on horizontal line Verify at least two studs have their centerlines within the center 32 5 of installation opening to ensure 2 wall studs are penetrated The bracket will b...

Страница 8: ...1 16 20 1 2 3 4 Overlay Panel 34 1 8 9 46 5 16 22 Grille Panel Fresh Food Panel Freezer Drawer Panel A B C D Door 1 4 Backer Panel 10 Spacer Panel Supplied Handles Trim 3 4 Overlay Panel 3 4 Overlay Panels Order trim kit ZTKBFHLH for 3 4 thick custom panels ordered from your cabinet maker The decorative panels slide into the trim The overlay panel must be secured to a 1 4 thick backer panel which ...

Страница 9: ...Secure the panels to the refrigerator with stick on hook and loop fastener strips Order the side panels from the cabinet manufacturer CUSTOM SIDE PANELS F 2 9 16 6 5 3 4 7 6 10 2 Depending on installation height 1 7 8 4 8 24 61 0 3 16 5 84 213 4 Depending on installation 84 213 4 Depending on installation height XRH _ZIFP360NXLH_ZIFP360NXRH_ ZIFS360NXLH_ZIFS360NXRH XRH_ZIRP360NXLH_ZIRP360NXRH_ZIRS...

Страница 10: ...tom panels ordered from your cabinet maker The decorative panels slide into the trim Maximum total panel weight Fresh food door panel 58 lbs Freezer drawer panel 28 lbs Grille panel 25 lbs Order ZUG2 Unified grille kit for dual installation 3 4 Overlay Panels Order trim kit ZTKBFHLH for 3 4 thick custom panels ordered from your cabinet maker The decorative panels slide into the trim The overlay pa...

Страница 11: ...14 6 A A separate 115V 60Hz 15 or 20 amp power supply is recommended for each product Additional cutout width may be required when side panels are used B In a side by side installation of a left and right hand door swing product 1 clearance between the units is required Order ZUG2 custom panel unified grille kit for one continuous grille panel DUAL PRODUCT CLEARANCES DUAL INSTALLATIONS 71 1 2 181 ...

Страница 12: ...ise temperature settings and are positioned for maximum ease of use Humidity Controlled Vegetable Compartments and Sealed Snack Pans Help maintain freshness and help preserve foods longer Adjustable Spill Proof Glass Shelves Make it easy to customize storage to handle foods and containers of various sizes 2 Sealed Deli Pans with Full Extension Slides Six Adjustable Door Bins Offer added storage fl...