– 29 –
Conversion Sticker Samples
A. From Natural Gas to LP
B. From LP to Natural Gas
THIS CONVERSION RATING LABEL RELATES TO THE
FOLLOWING GENERAL ELECTRIC MODELS
ZGU375
MINIMUM 11" W.C.
SUPPLY PRESSURE -
MAXIMUM 14" W.C.
MANIFOLD PRESSURE - 10" W.C.
INPUT
RATINGS
CENTER - 15,000 BTU/HR
FRONT - 8,500 BTU/HR
REAR - 8,500 BTU/HR
CONVERSION KIT CAT. No. WB49X10087
THIS APPLIANCE HAS BEEN CONVERTED ON
FROM NATURAL GAS TO L.P. GAS WITH CONVERSION
KIT CAT. No. WB49X10087
Name and address of qualified installer or service organization
WHO ACCEPTS RESPONSIBILITY FOR THE CORRECTNESS
OF THE CONVERSION
THIS CONVERSION RATING LABEL RELATES TO THE
FOLLOWING GENERAL ELECTRIC MODELS
ZGU375
MINIMUM 6" W.C.
SUPPLY PRESSURE -
MAXIMUM 9" W.C.
MANIFOLD PRESSURE - 4" W.C.
INPUT
RATINGS
CENTER - 15,000 BTU/HR
FRONT - 10,500 BTU/HR
REAR - 12,000 BTU/HR
CONVERSION KIT CAT. No. WB49X10088
THIS APPLIANCE HAS BEEN CONVERTED ON
FROM L.P. GAS TO NATURAL GAS WITH CONVERSION
KIT CAT. No. WB49X10088
Name and address of qualified installer or service organization
WHO ACCEPTS RESPONSIBILITY FOR THE CORRECTNESS
OF THE CONVERSION
STEP 6
(continued)
Burner Operation
Two flames are used on all five burners. These dual flame burners have an
upper ring of main burner ports which produce the main flame for high heat
cooking from the “HI” knob setting to the “LO” knob setting.
The bottom simmer flame is used for simmer heat cooking operations such as
melting chocolate, holding food at serving temperature and simmering.
Both flames are lit when the knob is between “HI” and “LO”.
Only the simmer flame is lit when the knob is in the “SIMMER” position.
Burner Adjustment
• There is no air shutter adjustment, etc. on this burner.
• The only adjustment available is to clean the burners and clean or
replace orifices.
STEP 7
Complete and adhere Conversion Sticker to the
Cooktop Bottom Surface
Complete the required information on the Conversion Sticker and adhere to
the bottom of the unit next to Rating Plate Sticker.
The Conversion sticker
MUST reflect the change in fuel.
Main Burner Ports
Simmer Flame
Simmer Ring
Burner Cap
High to Low
Flame
Simmer Flame
Содержание Monogram ZGU375NS