![GE Monogram ZGU375NS Скачать руководство пользователя страница 30](http://html2.mh-extra.com/html/ge/monogram-zgu375ns/monogram-zgu375ns_technical-service-manual_4297281030.webp)
– 28 –
STEP 4
Check for Leaks
Clocking Pattern
STEP 3
Convert the Pressure Regulator
NAT
LP
Reverse
Plastic Plunger
WARNING
Do not remove the pressure regulator from
the cooktop.
STEP 5
Assemble Burners, Check Ignition
Replace the cooktop, reconnect the wiring and reassemble the burners as
shown in Step 2. Make sure that burners are replaced in the “clocking”
pattern as shown.
• Check for proper ignition:
– Connect Electrical.
– Push in one control knob and turn 90
°
to “HIGH” position.
– The igniter will spark and the burner will light; the igniter will cease
sparking when the burner is lit. (Note that all burners will spark.)
– The first test may require some time while air is flushed out of the gas line.
– Turn knob to “OFF”.
– Repeat the procedure for each burner.
WARNING
Check for leaks before attempting to light
the burners.
• Check to be sure all controls are in the OFF position.
• Turn on the gas supply at the shutoff valve.
• Use a leak detector at all connections. If a leak is detected, tighten the
connection and test again.
DO NOT USE A FLAME TO CHECK FOR GAS LEAKS.
STEP 6
Check Flame Quality
Check for proper burner flame characteristics (see diagrams page 4).
Burner flames should be blue and stable.
Some yellow
tipping may be normal
on LP Gas. The flame should not have excessive noise or lifting of the flame
from the burner.
Due to differences in gas characteristics and burner usage (i.e. gas
pressure, cleanliness, etc.), burners may perform differently.
Cap Screw
NAT
LP
To convert the regulator from Natural Gas to LP gas or LP to
Natural, remove the cap screw using an adjustable wrench
and reverse the plastic plunger (make sure the plunger is
firmly “swapped” and seated in the cap screw, see illustration
to right).