background image

7

Installation

Stainless Steel G a s Cooktop

• Remove packaging from the cooktop.
• Position the cooktop over the opening,

making sure that the power cord is dropped
into the cabinet.

• Lower the cooktop into the cutout, pressing

gently and evenly to seat.

• Thumbscrew brackets are located on the

right and left sides of the cooktop.

• Turn thumbscrews to touch the underside of

the countertop until just finger tight. Do not
overtighten.

1

Install
Cooktop

Step

• Install the supplied pressure regulator and

nipple in the gas line as close to the cooktop
inlet as possible.
–Make sure the regulator is installed in the

right direction. See arrow on underside of
regulator.

• Install a manual shut-off valve in the gas line

in an easily accessible location.

NOTE: 

Instead of using solid piping to

connect to pressure regulator, an approved
flexible metal appliance connector may be
used between the pipe stub and the shut-off
valve to the pressure regulator, if local codes
permit.
– Appropriate flare nuts and adapters are

required at each end of the flexible
connector.

• Turn on the gas. Check for leaks using a

liquid leak detector at all joints in the system
(the pressure test fitting is on the side of the
regulator).

Do not use a flame to check for

gas leaks.

IMPORTANT: 

Disconnect the cooktop and

the individual shut-off valve from the gas
supply piping system during any pressure
testing of that system at test pressures greater
than 1/2 psig. Isolate the cooktop from the
gas supply piping system by closing the
individual manual shut-off valve to the
cooktop during any pressure testing of the
gas supply piping system at test pressures
equal to or less than 1/2 psig.

CAUTION

IL NE FAUT PAS UTILISER

DE FLAMME POUR VÉRIFIER S’IL Y A
DES FUITES.

CAUTION

PRUDENCE

2

Install
Pressure
Regulator

Step

NOTE: 

Refer to flow

direction arrow on
underside of regulator.

Countertop

Cooktop

Thumbscrew

1" Min.

Regulator

Solid Piping
or Flexible
Connector

Shut-Off
Valve

Pipe Stub From
House Gas Supply

To Cooktop

NOTE: 

Countertop

must be a minimum
of 1" thick at the
thumbscrew locations.

Содержание Monogram ZGU375LS

Страница 1: ...Monogram If you have questions call 800 GE CARES or visit our website at www monogram com Installation Instructions 36 Stainless Steel Gas Cooktops Natural Gas Model ZGU375NS LP Gas Model ZGU375LS...

Страница 2: ...CGA B149 1 or the current Propane Installation Code CAN CGA B149 2 and with local codes where applicable This cooktop has been design certified by the American Gas Association according to ANSI Z21 1...

Страница 3: ...ching over heated surface units Working areas adjacent to the cooktop should have 18 minimum clearance between countertop and cabinet bottom Use the Monogram gas stainless steel cook top with any 36 o...

Страница 4: ...nces The countertop must have a deep flat surface to accommodate the combined installation of the cooktop and vent The downdraft vent with blower motor and ductwork will occupy the base cabinet Consid...

Страница 5: ...pace below countertop If installing cooktop above a cabinet with drawers it may be necessary to use a shorter length drawer to allow clearance for gas connection In some cases two 3 8 I D 45 elbows an...

Страница 6: ...d in series with the manifold of the cooktop and must remain in series with the supply line regardless of type of gas being used The natural gas model is designed to operate at 5 water column pressure...

Страница 7: ...regulator if local codes permit Appropriate flare nuts and adapters are required at each end of the flexible connector Turn on the gas Check for leaks using a liquid leak detector at all joints in the...

Страница 8: ...turn 90 to HIGH position The igniter will spark and the burner will light the igniter will cease sparking when the burner is lit First test may require some time while air is flushed out of the gas li...

Страница 9: ...valent length when bends or various fittings are used Again refer to Downdraft Vent Installation Instructions for details Power Supply If local codes permit the vent and cooktop may operate from the s...

Страница 10: ...tion A 42 wide base cabinet should be used Narrow custom doors or decorative stiles can be used to fill the 6 gap on each side of the warming drawer 30 or 36 base cabinets are not recommended NOTE The...

Страница 11: ...V power supply See page 6 Where codes permit the gas shut off valve may be located in an adjacent cabinet or other easily accessible location IMPORTANT Base Cabinet Requirements for Combined Installat...

Страница 12: ...ions described in this book safety glasses or goggles should be worn For Monogram local service in your area call 1 800 444 1845 NOTE Product improvement is a continuing endeavor at General Electric T...

Отзывы: