background image

ZGU375NS
36" natural gas cooktop
ZGU375LS
36" LP gas cooktop

For those who prefer gas heat for
cooking, the Monogram built-in
gas stainless steel cooktop offers
the cooking method of choice.

• Refer to “Installation Preparation” for

information on appropriate placement
and necessary clearances when planning
installation.

• Avoid placing cabinetry directly above

cooktop when possible.

• If cabinetry is used above cooking surface:

– Use cabinets no more than 13" deep.
– Maintain 30" minimum clearance between

cooktop and unprotected cabinets directly
above cooktop.

– If clearance is less than 30", protect cabinet

bottoms with flame-retardant millboard at
least 1/4" thick, or gysum board at least
3/16" thick, covered with 28 gauge sheet
steel or .02" thick copper.

Advance
planning

Design Information

Stainless Steel G a s Cooktop

– Clearance between cooktop and protected

cabinetry must not be less than 24".

– An exhaust hood that projects at least 5"

beyond front of cabinets can reduce risk of
burns caused by reaching over heated
surface units.

– Working areas adjacent to the cooktop

should have 18" minimum clearance
between countertop and cabinet bottom.

• Use the Monogram gas stainless steel cook-

top with any 36" or wider exhaust hood with

350 CFM

 or greater air flow rating.

• Installation must conform with local codes.

In the absence of local codes, the gas cook-
top must comply with the National Fuel Gas
Code, ANSI Z223.1, latest edition.

3

Dimensions
and clearances

These models are factory set for either natural gas or
LP gas operation. Be sure to order the correct model
for the installation situation.

20-5/8"

Deep

at Center

19-3/4"

36-1/2"

5-1/2"

* If a countertop backsplash is used, it must be constructed
of non-combustible materials (such as masonry, ceramic,
granite, stainless steel, etc.) whenever the cutout to rear
vertical surface is less than 3-3/8".

IMPORTANT:

 Always maintain 2-3/4" Min. clearance from

cutout to front edge of countertop.

18-7/8"

3-3/8" Min. From Cutout 

to Vertical Combustibles

2-3/4" Min.

35-5/16"

11-9/16" Min. to

Wall From Cutout 

18" Min.

13"

Max.

36" Min.

2-15/16" Min.
From Cooktop
to Vertical 
Combustible 
Surface When 
Installed

11" Min. to Wall

From Cooktop Edge

When Installed Both Sides

30"

Min.

*

Содержание Monogram ZGU375LS

Страница 1: ...Monogram If you have questions call 800 GE CARES or visit our website at www monogram com Installation Instructions 36 Stainless Steel Gas Cooktops Natural Gas Model ZGU375NS LP Gas Model ZGU375LS...

Страница 2: ...CGA B149 1 or the current Propane Installation Code CAN CGA B149 2 and with local codes where applicable This cooktop has been design certified by the American Gas Association according to ANSI Z21 1...

Страница 3: ...ching over heated surface units Working areas adjacent to the cooktop should have 18 minimum clearance between countertop and cabinet bottom Use the Monogram gas stainless steel cook top with any 36 o...

Страница 4: ...nces The countertop must have a deep flat surface to accommodate the combined installation of the cooktop and vent The downdraft vent with blower motor and ductwork will occupy the base cabinet Consid...

Страница 5: ...pace below countertop If installing cooktop above a cabinet with drawers it may be necessary to use a shorter length drawer to allow clearance for gas connection In some cases two 3 8 I D 45 elbows an...

Страница 6: ...d in series with the manifold of the cooktop and must remain in series with the supply line regardless of type of gas being used The natural gas model is designed to operate at 5 water column pressure...

Страница 7: ...regulator if local codes permit Appropriate flare nuts and adapters are required at each end of the flexible connector Turn on the gas Check for leaks using a liquid leak detector at all joints in the...

Страница 8: ...turn 90 to HIGH position The igniter will spark and the burner will light the igniter will cease sparking when the burner is lit First test may require some time while air is flushed out of the gas li...

Страница 9: ...valent length when bends or various fittings are used Again refer to Downdraft Vent Installation Instructions for details Power Supply If local codes permit the vent and cooktop may operate from the s...

Страница 10: ...tion A 42 wide base cabinet should be used Narrow custom doors or decorative stiles can be used to fill the 6 gap on each side of the warming drawer 30 or 36 base cabinets are not recommended NOTE The...

Страница 11: ...V power supply See page 6 Where codes permit the gas shut off valve may be located in an adjacent cabinet or other easily accessible location IMPORTANT Base Cabinet Requirements for Combined Installat...

Страница 12: ...ions described in this book safety glasses or goggles should be worn For Monogram local service in your area call 1 800 444 1845 NOTE Product improvement is a continuing endeavor at General Electric T...