124
MDS iNET Series Reference Manual
05-2806A01, Rev. L
5.0 TECHNICAL REFERENCE
5.1
Data Interface Connectors
Three data interface connectors are provided on the face of the transceiver. The first, the LAN Port, is an
RJ-45 connector. The other two use two DB-9 interface connectors that use the RS-232 (EIA-232) signaling
standard. Note that the connector for
COM1
Port is DCE (Female DB-9) and the
COM2
Port is DTE (male
DB-9).
The transceiver meets U.S.A.’s FCC Part 15, Class A limits when used with shielded data cables.
5.1.1 LAN Port
The transceiver’s LAN Port is used to connect the radio to an Ethernet network. The transceiver provides a
data link to an Internet Protocol-based (IP) network via the Access Point station. Each radio in the network
must have a unique IP address for the network to function properly.
• To connect a PC directly to the radio’s
LAN
port, an RJ-45 to RJ-45 cross-over cable is required.
• To connect the radio to a Ethernet hub or bridge, use a straight-through cable.
The connector uses the standard Ethernet RJ-45 cables and wiring. For custom-made cables, use the pinout
information in Figure 5-1 and Table 5-1.
Figure 5-1. LAN Port (RJ-45) Pinout
(Viewed from the outside of the unit)
Table 5-1. LAN Port (IP/Ethernet)
Pin
Functions
Ref.
1
Transmit Data (TX)
High
2
Transmit Data (TX)
Low
3
Receive Data (RX)
High
4
Unused
5
Unused
6
Receive Data (RX)
Low
7
Unused
8
Unused
CAUTION
RADIO FREQUENCY
INTERFERENCE
POTENTIAL
1 2 3 4 5 6 7 8
Содержание MDS iNET Series
Страница 12: ...x MDS iNET Series Reference Manual 05 2806A01 Rev L...
Страница 159: ...05 2806A01 Rev L MDS iNET Series Reference Manual 147 Figure A 22 EDS Wizard Completion Screen...
Страница 165: ...05 2806A01 Rev L MDS iNET Series Reference Manual 153 NOTES...
Страница 166: ...154 MDS iNET Series Reference Manual 05 2806A01 Rev L NOTES...
Страница 173: ...GE MDS LLC Rochester NY 14620 General Business 1 585 242 9600 FAX 1 585 242 9620 Web www gemds com 175 Science Parkway...