MDS Master Station Setup Guide 

05-6398A01, Rev. C 

c.

      Click on 

Sd Config

 

 

 

d.

      Redundant radios share a common configuration and are 

managed simultaneously through 

Radio

Security

, or 

Maintenance 

and Status

... 

 

Note that the links at the top of the page can be used to easily return to 
an earlier web page. 

 

3.2 

Configuration via Command Line (CLI) 

A scriptable command-line interface is accessible through the Ethernet 
port using Secure Shell (SSH) terminal, Serial Port, or thro

ugh the unit’s 

USB interface. For enhanced security, the unit does 

not

 support Telnet 

configuration. The steps below describe a cabled USB connection and 
assume the proper drivers have been installed (Drivers are located free 
of charge at 

www.gemds.com

).   

1.  

Connect a PC to the unit's USB port and establish a console 
terminal session using a serial communications program. 

2.  

Press the ENTER key to receive the login prompt; the USB interface 
will auto-baud.   

3.  

Enter the 

Username

 (

admin

 is the default username) and press 

ENTER. 

4.  

At the 

Password

 prompt, enter the password (

admin

 is the default 

password). Press ENTER. Upon successful login, the connection 
message appears. 

5.  

Enter the configuration mode by typing 

configure

 followed by the 

ENTER key. 

6.  

Review and configure all key settings for the required application. 
Built-in help is available by pressing the Tab key. A summary of all 
unit settings may be viewed by entering the 

% show | details 

command

Tab-completion

 is a powerful feature that provides assistance when 

typing commands in the CLI. Depending on the text that was already 
entered, tab-completion displays different possible completions. When 
the Tab key is pressed and no text has been entered, the CLI shows all 
possible commands that can be typed. 

 

Key items that should be reviewed or set for the unit are as follows: 

•  

Create one-time programmable passwords for unit recovery 

•  

Change login passwords (to maintain security) 

•  

Evaluate default factory configuration and lock the unit down to 
the required security level 

•  

Radio configuration, including TX/RX frequency plan, modem 
selection, keying mode, encryption, and serial data interface 
configuration. 

Refer to the 

Technical Manual

 for details on the above items. 

7.  

When finished, log out of the console session and disconnect the 
PC from the Master Station. 
 

4.0  IN-SERVICE OPERATION 

In-service operation of the MDS Master Station is completely automatic. 
The only operator actions required are to apply power and check the 
module LEDs for proper indications as shown. 

Table 4: Module LED Descriptions

 

Module 

LED Name 

Function 

Platform Manager 

PWR 

On

—Power applied 

Flash

—System bootup 

Platform Manager 

PWR & ALARM ON 
(pre-bootup) 

System Initialization 

Platform Manager 

ALARM 

Flashing

—Alarmed (SD 

Master) 

Radio 

PWR/ALARM 

On

—Power applied 

Flashing

—Alarmed radio 

Radio 

ACTIVE 

On

—Active 

Off

—Standby 

Radio 

TX 

On

—Transmitting 

Off

—No Data 

Radio 

RX 

On

—Receiving 

Off

—No Data 

Alarm/Relay 

ALARM MAJ 

On

—Major Alarm (SD 

Master) 

Alarm/Relay 

ALARM MIN 

On

—Minor Alarm (SD 

Master) 

Alarm/Relay 

ACT A 

On

—Radio A Active 

Off

—Radio A Standby 

Alarm/Relay 

ACT B 

On

—Radio B Active 

Off

—Radio B Standby 

 

5.0  COM1/COM2 REFERENCE 

The COM port is commonly used to connect an external DTE telemetry 
device to the unit, supporting either the RS-232 or RS-485 (balanced) 
format, depending on how the device is configured. The unit supports 
data rates of 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 
115200 bps (asynchronous data only). 

This connector mates with a standard RJ-45 plug (see 

Figure 8

available from many electronics parts distributors. 

5.1 

Pin Descriptions

—RS-232 Mode 

Pin descriptions for the COM connector in RS-232 mode are shown in 
Table 5 and Table 6 on the following page. Note that the unit is hard-
wired as a DCE device. Refer to the 

Technical Manual

 for RS-422/485 

descriptions. 

(Note: RS-485 supported on COM2 only.) 