GE JV535 Скачать руководство пользователя страница 6

BEFORE YOU BEGIN

6

Installation

Range Hood

Instructions

Models JV535 JV635  

JV536 JV636  

JV565 JV665 

JV566 JV666

Read these instructions completely and carefully.

IMPORTANT –

Save these

instructions for local inspector’s use.

IMPORTANT –

Observe all

governing codes and ordinances.

Note to Installer –

Be sure to leave these

instructions with the Consumer.

Note to Consumer –

Keep these instructions

for future reference.

Skill level

– Installation of this appliance requires

basic mechanical and electrical skills.

Completion time

– 1-3 hours

Proper installation is the responsibility of the

installer. 

Product failure due to improper installation is not

covered under the Warranty.

NOTE: Read the ductwork sections only if you do not
have existing ductwork. If you have existing ductwork,
skip to the “Damage” section and proceed.

The venting system must exhaust to the outside.

This hood can be vented vertically through upper
cabinets or horizontally through an outside wall.
Ductwork is not included.

Exhaust connection: 

The hood exhaust has been designed to mate with
standard 3

1

4

x 10

rectangular ducting or 7

diameter

round ducting.
If a 6

round duct is required, a rectangular-to-round

transition adaptor must be used*. 

Do not use less than 

a 6

diameter duct.

Maximum duct length: 

For satisfactory air movement, the total duct length 
of a 3

1

4

x 10

rectangular, 6

or 7

diameter round 

duct 

should not exceed 65 equivalent feet. 

NOTE:

It’s important that ducting be installed using 

the most direct route and with as few elbows as possible. 
This ensures clear venting of exhaust and helps prevent
blockages. 

Also, make sure dampers swing freely and

nothing is blocking the ducts.

Elbows, transitions, wall and roofcaps, etc.,

present additional resistance to airflow and are
equivalent to a section of straight duct longer than their
actual physical size. When calculating the total duct
length, add the equivalent lengths of all transitions and
adaptors plus the length of all straight duct sections. The
charts on the following pages show you how to calculate
total equivalent ductwork length using the approximate
feet of equivalent length of some typical ducts.

* IMPORTANT:

If a rectangular-to-

round transition adaptor is used, the
bottom corners of the damper will
have to be cut to fit, using the tin
snips, in order to allow free
movement of the damper. 
Equivalent lengths of duct pieces 
are based on actual tests and reflect
requirements for good venting
performance with any hood.

DUCTWORK REQUIREMENTS

WARNING –

Before beginning the

installation, switch power off at service panel and lock
the service disconnecting means to prevent power
from being switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, 
to the service panel.

FOR YOUR SAFETY:

Questions? 

Visit our Website at: 

www.geappliances.com 

or 

Call GE Answer Center at 800.626.2000

Содержание JV535

Страница 1: ...rcoal Filters 5 Grease Filters 4 Hood Lights 5 Hood Surfaces 5 Stainless Steel Surfaces 5 Vent Controls 4 Installation Instructions 6 14 Customer Service Product Registration 2 Service Telephone Numbe...

Страница 2: ...back wall of the hood Staple sales slip or cancelled check here Proof of the original purchase date is needed to obtain service under the warranty If you do need service you can relax knowing help is...

Страница 3: ...mall and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit Based on Kitchen Firesafety Tips published by NFPA WARNING TO R...

Страница 4: ...reusable grease filters The metal filters trap grease released by foods on the cooktop They also help prevent flaming foods on the cooktop from damaging the inside of the hood For this reason the fil...

Страница 5: ...lish Follow the product instructions for cleaning the stainless steel surface Stainless Steel Surfaces on some models This hood requires two bulbs not included maximum 50 watts Purchase and install PA...

Страница 6: ...or 7 diameter round duct should not exceed 65 equivalent feet NOTE It s important that ducting be installed using the most direct route and with as few elbows as possible This ensures clear venting of...

Страница 7: ...nd Equivalent Length in Feet 0 25 50 75 100 125 150 31 4 x 10 Rectangular Transition to 6 Round 4 5 ft 7 Round 90 Elbow 8 ft 7 Roof Cap 30 ft 400 350 300 250 200 Air Volume in CFM 31 4 x 10 Rectangula...

Страница 8: ...GTH DUCT EQUIVALENT NUMBER PIECES LENGTH x USED TOTAL 6 Round 34 Ft x Ft wall cap 6 ft w o with damper x Ft damper 6 Round 30 Ft x Ft roof cap 6 Round 5 5 Ft x Ft to 31 4 x 10 rect transition 6 Round...

Страница 9: ...UDED Some parts are shipped in the hood behind the filters On some models the bottom cover of the hood also needs to be removed to gain access to the parts MOUNTING SPACE NOTES This range hood is for...

Страница 10: ...e If the hood is to be installed in a recirculating non vented ductless manner do not knock out any vent openings in the hood Only an electrical access hole will be knocked out of the hood NOTE Only J...

Страница 11: ...screws REMOVE OTHER EXHAUST ADAPTOR Remove the 31 4 x 10 rectangular exhaust adaptor from inside the hood Set it aside along with its mounting screws and parts bag Depending on the model the exhaust...

Страница 12: ...Top back edge Exhaust adaptor damper vertical discharge position shown Pivot FOR 7 ROUND VERTICAL DUCTED DISCHARGE INSTALLATIONS ONLY Re install the 7 round exhaust adaptor with its screws removed in...

Страница 13: ...CABINETS ONLY RUN WIRES Run the electrical wires through the wall or cabinet according to National Electrical Code and applicable local codes NOTE DO NOT turn the power on until installation is comple...

Страница 14: ...SH ON FAN BLADE Pushing on the blade may cause it to interfere with other hood parts FOLLOW ELECTRICAL CODE Complete the electrical wiring according to National Electrical Code and local codes NOTE Th...

Страница 15: ...r resetting of circuit breakers Damage to the product caused by accident fire floods or acts of God Incidental or consequential damage caused by possible defects with this appliance What GE Will Not C...

Страница 16: ...bstantial discount GE Consumer Service will still be there after your warranty expires Parts and Accessories 800 626 2002 Individuals qualified to service their own appliances can have parts or access...

Отзывы: