Dimensions and Installation Information (in inches) 

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

ge.com or call GE Answer Center

®

 service,  

800.626.2000.

Listed by 

Underwriters 

Laboratories

JP655TK/BK 

GE

®

 36" Built-In CleanDesign Electric Cooktop

 

Note:

 Check local codes for required breaker size

Important:

 Requires a 5" free area between  

the bottom of the cooktop to any combustible 
material, i.e., shelving. Free area not required 
when installing wall oven underneath cooktop. 
Refer to installation instructions. Requires an  
18" minimum from cooktop to adjacent  
overhead cabinets. Units are furnished with  
a 48" flexible armored cable. 

Note:

 36" Ribbon cooktops are approved for use over GE 30" Single Wall 

Ovens and Warming Drawers only. Refer to cooktop and wall oven/ 
warming drawer installation instructions packed with product for current 
dimensional data. If installed with a GE Profile

™ 

Telescopic Downdraft System, 

consult both the cooktop and downdraft installation instructions packed with 
product before installing. Cooktop gas/electric supply may need to be  
re-routed to install downdraft. The countertop must be at least 26" deep  
with a flat surface area of 23-1/2" or more, front to back. In addition,  
other clearances to the front edge of the countertop must be considered,  
especially on raised bullnose countertops. Consult cabinet and countertop 
manufacturer’s specs for flush mount installation prior to install. 

Flush Mount Installation Kit :

 Accommodates both 30" and 36" installations. 

Not for use with stainless steel models. JXFLM2TW (True White glass)  
JXFLM2CC (True Bisque glass) JXFLM2BB (Black – black glass cooktops) 

Installation Information: 

Before installing, consult installation instructions 

packed with product for current dimensional data. 

KW Rating

240V

8.4

208V

6.3

Breaker Size

240V

40 Amps

208V

40 Amps

3-1/4*

Cooktop

2-1/2**

Required

33-7/8

19-1/8

36

36_color_cktp_install.eps

20-7/8

Electrical junction box 16" MIN. 

below countertop

30" MIN. to

unprotected

cabinet

Cut should 

not interfere 

with cabinet

structure 

at front

2" MIN.

clearance to

side wall

from cut-out

2" MIN.

clearance to

side wall

from cut-out

1-3/4" to

rear wall

13" MAX.

depth

  * Depth of unit at conduit connection location (rear) is 

6-1/2" on models PP980/975/950/945 and 4-5/8" 

on models PHP960/PP972/962/942/932/912, 

JP655/356/346.

 **Raised bull nose countertops may require up to 

3/8" additional clearance to prevent interference 

with curved front.

15" MIN.  

to cabinet

Specification Revised 12/07

321352