background image

2

31-11072-1

Installation Instructions

IMPORTANT SAFETY INSTRUCTIONS

FOR YOUR SAFETY

•  

For Personal Safety, remove house fuse or open 
circuit breaker before beginning installation. Failure 
to do so could result in serious injury or death.

•  

Be sure your cooktop is installed properly by a 
qualified installer or service technician.

•  

To eliminate the risk of burns or fire due to reaching 
over heated surface elements, cabinet storage 
located above the surface units should be avoided. 
If cabinet storage space is to be provided, the risk 
can be reduced by installing a range hood that 
projects horizontally a minimum of 5" beyond the 
bottom of the cabinets. Cabinet installation above 
the cooktop may be no deeper than 13".

•  

Make sure the cabinets and wall coverings around 
the cooktop can withstand the temperatures (up to 
200°F) generated by the cooktop.

•  

The cooktop should be easy to reach and lighted 
with natural light during the day.

•  

Always disconnect the electrical service to the 
cooktop before repairing or servicing the cooktop. 
This can be done by disconnecting the fuse or 
circuit breaker. Failure to do this could result in a 
dangerous or fatal shock. Know where your main 
disconnect switch is located. If you do not know, 
have your electrician show you.

ELECTRICAL REQUIREMENTS

This appliance must be supplied with the proper 
voltage and frequency, and connected to an individual, 
properly grounded branch circuit, protected by a circuit 
breaker or a time delay fuse as noted on name plate 
and the chart below. 

We recommend you have the electrical wiring and 
hookup of your cooktop connected by a qualified 
electrician. After installation, have the electrician show 
you where your main cooktop disconnect is located.

Wiring must conform to National Electrical Code. You 
can get a copy of the National Electrical Code, ANSI/
NFPA No. 70-Latest Edition, by writing to:

National Fire Protection Association

Batterymarch Park

Quincy, MA  02269

The cooktop conduit wiring is approved for copper 
wire connection only, and if you have aluminum house 
wiring, you must use special UL approved connectors 
for joining copper to aluminum.

You must use a two-wire, three conductor 208/240 
VAC, 60 Hertz electrical system. A white (neutral) 
wire is not needed for this unit. The cooktop must be 
installed in a circuit that does not exceed 125 VAC 
nominal to ground.

Refer to the name plate on your cooktop for the KW 
rating for your cooktop.

Use the chart below to determine the minimum 
recommended dedicated circuit protection:

Name plate location

KW Rating 240v

KW Rating 208V

Recommended 

Circuit Size 

(Dedicated)

”.:

”.:

20 Amp

4.9 KW - 7.2 KW

4.2 KW - 6.2 KW

30 Amp

7.3 KW - 9.6 KW

6.3 KW - 8.3 KW

40 Amp

9.7 KW - 12.0 KW

8.4 KW - 10.4 KW

50 Amp

Содержание JP3030D

Страница 1: ...proper installation is NOT covered under warranty 30 and 36 Electric Cooktop Radiant Excludes Down Draft Models MATERIALS YOU WILL NEED TOOLS NEEDED CUTTING THE COUNTERTOP If you are installing the co...

Страница 2: ...you ELECTRICAL REQUIREMENTS This appliance must be supplied with the proper voltage and frequency and connected to an individual properly grounded branch circuit protected by a circuit breaker or a ti...

Страница 3: ...ngs countertop and cabinets around the cooktop can withstand heat up to 200 F generated by the cooktop H Installing cooktop in combination with other products Both products must be installed according...

Страница 4: ...length of cut 1 3 4 MIN Between rear edge of cutout and the wall behind the cooktop 19 5 8 19 3 4 30 19 1 8 19 1 4 36 width of cut 2 1 2 MIN From front edge of cutout and front edge of countertop Size...

Страница 5: ...mericans with Disabilities Act ADA Forward Approach Installation Only NOTE The enclosure must be made of wood material Also an access panel is required for the junction box hold down brackets and serv...

Страница 6: ...and ZEU36 models apply the foam tape around the outer edge of the glass on the sides and rear of the unit only 4 MOUNTING PARTS Remove the hold down brackets and screws from the literature package Scr...

Страница 7: ...length of conduit provided The conduit must not be shortened B With the cooktop in place open the front of the cabinet door C Insert the wires from the conduit through the opening of the junction box...

Страница 8: ...hed or in contact with moving parts C Check level of appliance D Check that the cooktop is properly grounded NOTE TO ELECTRICIAN The power leads supplied with this appliance are UL recognized for conn...

Страница 9: ...recta es responsabilidad del instalador y el mal funcionamiento del producto debido a una instalaci n inadecuada NO est cubierto bajo la garant a NECESITAR LOS SIGUIENTES MATERIALES HERRAMIENTAS QUE P...

Страница 10: ...ubicaci n REQUISITOS EL CTRICOS Este aparato debe contar con el voltaje y frecuencia adecuados y deber conectarse a un circuito derivado individual debidamente descargado a tierra protegido por un cor...

Страница 11: ...ci n en combinaci n con otros productos Ambos productos deben ser instalados de acuerdo con sus instrucciones de instalaci n espec ficas del producto Se deben tener en consideraci n los requisitos y u...

Страница 12: ...36 longitud del corte M NIMO de 1 entre el extremo trasero de la abertura y la pared detr s de la superficie de cocci n 19 5 8 19 3 4 30 19 1 8 19 1 4 36 ancho del corte M NIMO de 2 1 2 desde el extre...

Страница 13: ...uierdo de la unidad que est por debajo de una altura de despeje m nimo de 15 Despeje m nimo de 15 desde la mesada hasta el lado inferior de los gabinetes m s cercanos a ambos lados de la superficie de...

Страница 14: ...inta de espuma alrededor del borde externo del vidrio en los lados y borde posterior de la unidad 4 LAS PARTES DE MONTAJE Saque las abrazaderas de montaje y tornillos del empaque con material impreso...

Страница 15: ...ducto no debe reducirse B Con la estufa colocada en su lugar abra el frente de la puerta del gabinete C Inserte los cables del conducto a trav s de la abertura de la caja de conexiones D Conecte los c...

Страница 16: ...to con partes m viles C Verifique el nivel del aparato D Verifique que la estufa est descargada a tierra correctamente 2 LISTA DE VERIFICACI N DE OPERACI N A Retire todos los objetos que se encuentren...

Отзывы: