![GE JK3800DH1BB Скачать руководство пользователя страница 71](http://html1.mh-extra.com/html/ge/jk3800dh1bb/jk3800dh1bb_technical-service-manual_4173095071.webp)
– 71 –
Mini Manual # 31–17121–1 (available on website).
Dead Unit
If Control does not show any display, after verifying the circuit breaker is ON, check
for 120 VAC at the black wire on the BROIL relay to the white wire on J102, with
wires still connected to board. If 120 VAC is present, Control needs to be replaced. If
less than 90 VAC, check voltage from the white wire on J102 to the chassis ground;
if 120 VAC, neutral limit switch is open, or house supply voltage is at fault.
$//7(676%(/2:$5(5(6,67$1&(&+(&.6³',6&211(&729(1)52032:(5
No Bake
If the Bake element is not energizing, check the resistance on the yellow wire of the
bake relay to the orange
ZLUHRQWKH'/%UHOD\$SSUR[LPDWHO\ű
No Broil
If the Broil element is not energizing, check the resistance on the purple wire of the
broil relay to the orange
ZLUHRQWKH'/%UHOD\$SSUR[LPDWHO\ű
No Convection
If the Convection element is not energizing, check the resistance on the blue wire of
J803 to the orange
ZLUHRQWKH'/%UHOD\$SSUR[LPDWHO\ű
No Bake, Broil or
Convection
If all elements are not energizing, the L2 High Limit Switch is open.
All 120 volt components
No Cooling Fan
Motor High
If the Cooling Fan High is not energizing, check the resistance on the black/white
wire on J801-3 to the white
ZLUHRQ-$SSUR[LPDWHO\ű
No Cooling Fan
Motor Low
If the Cooling Fan Low is not energizing, check the resistance on the red/white wire
on J801-2 to the white
ZLUHRQ-$SSUR[LPDWHO\ű
No Cavity Lamps
If the Cavity Lamps are not energizing, check the resistance on the black wire on
J801-1 to the white
ZLUHRQ-$SSUR[LPDWHO\ű
No Convection Fan
If the Convection Fan Motor is not energizing in the clockwise direction, check the
resistance on the blue wire on J801-5 to the white wire on J102. Approximately
ű
No Lock Motor
If the Lock Motor is not energizing, check the resistance on the grey/black wire on
J801-6 to the white
ZLUHRQ-$SSUR[LPDWHO\Nű
Bridge Board Communication Error
If this error is displayed, check the two wire connector between the ovens and at the Bridge Board.
If no problems are found, replace the Bridge Board.