Wire tips

Terminal 
block

Conduit

3-WIRE INSTALLATION

WARNING:

The neutral or ground wire of the power cord must be connected 

to the neutral terminal located in the center of the terminal block and the ground strap
must connect the neutral terminal to the ground plate. The power leads must be 
connected to the lower left and the lower right terminals of the terminal block.

DO NOT remove the ground strap connection.

FOR POWER CORD INSTALLATION

A. 

Remove the 3 lower terminal screws from the terminal block. 

B.

Insert the 3 terminal screws through each power cord terminal ring and into the lower 
terminals of the terminal block. Be certain that the center wire (white/neutral) 
is connected to the center lower position of the terminal block. 

C.

Tighten screws securely into the terminal block.

FOR CONDUIT INSTALLATION

A. 

Loosen the 3 lower terminal screws on the terminal block. Strip wire to exposed tip about 5/8”
long.

B. 

Insert the center (white/neutral) wire tip through the bottom center terminal block opening. 
On certain models, the wire will need to be inserted through the ground strap opening 
and then into the bottom center block opening. Insert the two side bare wire tips into the lower
left and the lower right terminal block openings. 

C. 

Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do not over-tighten 
the screws.

NOTE: ALUMINUM WIRING: 

Aluminum building wire may be used but it must be rated 

for the correct amperage and voltage. 

PROCEED TO STEP 7.

5

Ground strap

Terminal block 
(appearance
may vary)

Neutral terminal

Power cord

Ground 
plate

Power Cord

Conduit

31-10677

08-08

JR

4-WIRE INSTALLATION

WARNING:

The neutral wire of the supply circuit must be connected to the neutral terminal 

located in the lower center of the terminal block. The power leads must be connected to the lower left
and the lower right terminals of the terminal block. The grounding lead must be connected to the frame 
of the range with the ground plate and the green ground screw.

FOR POWER CORD INSTALLATION

A. 

Remove the 3 lower terminal screws from the terminal block. Remove the ground screw and
ground plate and retain them.

Cut and discard the ground strap. DO NOT DISCARD ANY SCREWS.

B.

Insert the one ground screw into the power cord ground wire terminal ring, through the ground plate 
and into the frame of the range.

C.

Insert the 3 terminal screws (removed earlier) through each power cord terminal ring and into the lower 
terminals of the terminal block. Be certain that the center wire (white/neutral) is connected to the center
lower position of the terminal block. Tighten screws securely into the terminal block.

FOR CONDUIT INSTALLATION

A.

Loosen the 3 lower terminal screws on the terminal block. Remove the ground screw and ground plate
and retain them. 

Cut and discard the ground strap. DO NOT DISCARD ANY SCREWS. 

Strip wire

to exposed tip about 5/8” long.

B.

Insert the ground bare wire tip between the range frame and the ground plate (removed earlier) 
and secure it in place with the ground screw (removed earlier). Insert the bare wire (white/neutral) tip
through the bottom center of the terminal block opening. Insert the two side bare wire tips into the lower
left and the lower right terminal block openings. 

C.

Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do not over-tighten the screws.

NOTE: ALUMINUM WIRING: 

Aluminum building wire may be used but it must be rated 

for the correct amperage and voltage. 

6

Before–Power Cord and Conduit

Terminal
block

Terminal
block

Neutral 
terminal

Neutral
terminal

Ground
strap

Ground plate
(grounding to
range)

Ground
screw

Ground strap 

or

After–Conduit

Terminal
block

Ground
plate
(grounding
to range)

Wire
tips

Ground screw

After–Power Cord

Содержание JB620DRBB

Страница 1: ...rely fasten a prominent warning device such as a tag to the service panel PREPARE THE OPENING FOR INDOOR USE ONLY See illustrations for all rough in and spacing dimensions The range may be placed with 0 clearance flush at the back wall and side walls of the cabinet 2 21 2 21 2 71 2 25 47 253 8 7 141 2 On models with baking or warming drawers electrical outlet must not be in this area 31 4 31 4 73 ...

Страница 2: ...e cord rated at 40 amps with 125 250 minimum volt range is required A 50 amp range cord is not recommended but if used it should be marked for use with nominal 13 8 diameter connection openings Care should be taken to center the cable and strain relief within the knockout hole to keep the edge from damaging the cable The rating plate is located on the oven frame or on the side of the drawer frame ...

Страница 3: ...rminal block The power leads must be connected to the lower left and the lower right terminals of the terminal block The grounding lead must be connected to the frame of the range with the ground plate and the green ground screw FOR POWER CORD INSTALLATION A Remove the 3 lower terminal screws from the terminal block Remove the ground screw and ground plate and retain them Cut and discard the groun...

Страница 4: ...it fuses are replaced Be sure power is in service to the building Check that all packing materials and tape have been removed This will include tape on metal panel under control knobs if applicable adhesive tape wire ties cardboard and protective plastic Failure to remove these materials could result in damage to the appliance once the appliance has been turned on and surfaces have heated Check th...

Страница 5: ...evitar una interferencia con el cajón de almacenamiento Los cables de energía de 41 2 a 6 de largo pueden tener que cubrirse para poder cerrar el cajón correctamente DIMENSIONES MÍNIMAS ENTRE LA ESTUFA LAS PAREDES Y SOBRE LA PARTE SUPERIOR DE LA ESTUFA A Verifique que el revestimiento de las paredes el mostrador el piso y los gabinetes ubicados alrededor de la cocina puedan soportar el calor hasta...

Страница 6: ...ivio de tensión Se requiere un cable para cocinas clasificado para 40 amperios con rango de voltios mínimo de 125 250 No se recomienda un cable de 50 amperios pero si se utiliza debe señalizarse para usarse con aberturas de conexión de un diámetro nominal de 1 3 8 Debe tenerse cuidado al centrar el cable y el alivio de tensión dentro del orificio de expulsión para evitar que el borde dañe el cable...

Страница 7: ...erminales inferior izquierda e inferior derecha del bloque terminal El cuarto cable a tierra debe estar conectado al marco de la cocina con la placa de conexión a tierra y el tornillo a tierra PARA INSTALACIÓN DE CABLE DE ENERGÍA A Quite los 3 tornillos inferiores del bloque terminal Quite el tornillo a tierra y la placa de conexión a tierra y consérvelos Corte y descarte la cinta de conexión a ti...

Страница 8: ...ACIÓN Verifique que el interruptor de circuitos se encuentre cerrado RESET o que los fusibles del circuito se hayan reemplazado Asegúrese de que se cuente con suministro eléctrico en el edificio Controle que se haya quitado todo el material de empaque y la cinta Esto incluye cinta sobre el panel de metal bajo las perillas de control si corresponde cinta adhesiva ataduras de alambre cartón y plásti...

Отзывы: