background image

Electrical Connections

DALI

Fi

xt

ur

e

Neutral

Ground

Line

DALI
DALI

White
Green

Black

Violet/White
Violet

0-10V

Fi

xt

ur

e

Neutral

Ground

Line

(0-10V) +

(0-10V) –

White
Green

Black

Violet
Grey

2

4

Carefully remove appropriate knockout for AC line input 

wires (inner knockout for ½” conduit, outer knockout 

for ¾” conduit). Install listed electrical fittings in the 

knockout holes for wire protection and pass supply 

conduit through electrical fittings. 

Optional dimmer:

 Install UL listed electrical fitting and 

insert dimming control wires through. Connect dimming 

control wires (grey and violet for 1-10V or violet and 

violet/white strip for DALI) to the similarly colored fixture 

wire using the provided push-in wire-nuts.

1

3

5

Remove knockout plate from luminaire by loosening the 

knockout screw and sliding the cover out of luminaire.

Connect the green (ground) wire to the green ground 

wire of the luminaire using the provided push-in wire-

nut. Connect the black (line) and white (neutral) wires 

of the AC line to the black and white wires of the power 

supply unit using the provided push-in wire-nuts.

Carefully push the wire bundle back into the body of the 

luminaire. Replace plate and re-tighten mounting screw. 

Wiring Diagrams

Содержание IP180 Series

Страница 1: ...limentation électrique RISQUES D INCENDIE Respectez tous les codes NEC et codes locaux N utilisez que des fils approuvés par UL pour les entrées sorties de connexion Taille minimum 18 AWG Save These Instructions Use only in the manner intended by the manufacturer If you have any questions contact the manufacturer Prepare Electrical Wiring Electrical Requirements The LED driver must be supplied wit...

Страница 2: ...n instructions of the selected suspension method before attempting to perform any electrical interconnections 1 Carefully unpack unit from its packaging Properly inspect for defects before installing Wear work gloves to prevent dirt and oil from being transferred to the luminaire 4 6 3 5 Temporarily align two adjacent luminaires by sliding the tabs into the corresponding slots Optional Continuous ...

Страница 3: ...ng control wires through Connect dimming control wires grey and violet for 1 10V or violet and violet white strip for DALI to the similarly colored fixture wire using the provided push in wire nuts 1 3 5 Remove knockout plate from luminaire by loosening the knockout screw and sliding the cover out of luminaire Connect the green ground wire to the green ground wire of the luminaire using the provid...

Страница 4: ...following standards Symptom Solution Luminaires will not turn on Check that the color of the supply side wires match the color of the wires they are connected to Check that the LED driver connector is fully engaged to the LED light engine connector Check that the LED light engines are connected at the juction between the two luminaires Luminaire on through wiring will not turn on Check that the th...