Appendix
KTD-125/127 PTZ Receivers User Manual
Zoom
▼
Focus
▼
Iris
▼
Pan
▼
Pan
▼
Tilt
▼
Up
►
In Near
Open
Manual
Left Up
Down
►
Out Far Close
Auto
Right
Down
Figure 39. On-site toggle switch positions for KTD-127 units
A
PPENDIX
C. A
UXILIARY
P
OWER
O
UTLET
(KTD-
125/125P)
Use the auxiliary power connection on the main relay board to power a
test monitor on site or an auxiliary transformer for low voltage camera
supplies.
A
PPENDIX
D: A
SSIGNING
DIP S
WITCH
V
ALUES
One way to determine which switches to use is to subtract the highest
possible switch value from the address you want, then subtract the
highest possible switch value from that difference. Continue to subtract
the highest possible switch value from the difference until you have zero.
For example, if you want address 209:
Switch Address 209
Switch
Value
Difference
Switch
On
209
– 128 =
81
8
81 – 64 =
17
7
17 – 16 =
1
5
1 – 1 = 0
1
34
1040823A / June 2003