background image

D e t a i l e d   O p e r a t i o n

Integrated Keypad

34

6" QuickPanel View Keypad

GFK-2357A

3

Some keys that are available on a standard keyboard are not available on the 
QuickPanel View Keypad, including Escape, Caps Lock, and tilde (~).

Note: 

Characters that are unavailable via the keypad can typically be accessed via 

the Soft Input Panel (see page 35).

The Fn key enables the alternate character set on the function/alpha keypad and on 
the numeric keypad. If Fn is not active, the function keys report as F1 through F26 
and the numeric keys report as 0 to 9, the decimal point (.), and the minus symbol 
(-). If Fn is active, the keys report as the labels on their upper right indicate. 

For a list of keyboard operating system shortcuts, see page 13.

To enabl e and d isabl e the alternate c har acter set o n the keyp ad

• Press and release the 

Fn

 key once to enable the alternate character set. Press it again to disable the alternate 

character set. 

When the 

Fn

 key is pressed once, an icon displays in the system tray. 

Fn

 key ‘on’

Содержание IC754VGI06SKD

Страница 1: ...GE Intelligent Platforms Hardware User s Guide GFK 2357A 6 QuickPanel View Keypad IC754VSI06SKD IC754VGI06SKD Intermediate Color April 2010 ...

Страница 2: ...e the information contained herein does not purport to cover all details or variations in hardware or software nor to provide for every possible contingency in connection with installation operation or maintenance Features may be described herein which are not present in all hardware and software systems GE Intelligent Platforms assumes no obligation of notice to holders of this document with resp...

Страница 3: ...is unavailable Technical Support Email support ip ge com Customer Care Email customercare ip ge com Primary language of support English Europe the Middle East and Africa Online Technical Support www ge ip com support Phone 800 1 433 2682 EMEA Direct Dial 352 26 722 780 if toll free 800 option is unavailable or if dialing from a mobile telephone Technical Support Email support emea ip ge com Custom...

Страница 4: ......

Страница 5: ... and without notice 2007 GE Intelligent Platforms Americas All rights reserved QuickPanel View and QuickPanel Control are trademarks of GE Intelligent Platforms Americas in the United States and other countries Any other trademarks referenced herein are the property of their respective owners and used solely for purposes of identifying compatibility with the products of GE Intelligent Platforms Am...

Страница 6: ...manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Any changes or modifications to the product or installation that are not expressly approved by GE Intelligent Platforms could void the user s authority to operat...

Страница 7: ...ws CE NET 13 Working with Windows CE 13 Pocket Internet Explorer 14 Backup 16 Reboot 17 Storage Manager 18 System Information 18 Copy Project to Flash Card 19 Emulate PPC 19 HTTP File Transfer Utility 21 FTP Server 22 3 Detailed Operation 27 Touch Screen Display 28 Touch Screen 30 Integrated Keypad 33 Keypad Operation 33 Soft Input Panel 35 Communication Port 38 COM1 Serial 38 Recommended Cabling ...

Страница 8: ...wer Management 56 Battery Backup 56 Real time Clock 57 Configuring SNTP 58 A1 Design Specifications 61 Physical 61 DC Power 61 Display 62 Front Panel 62 Keypad 62 Touch Screen 62 CPU 62 Memory 63 Memory Expansion Slot 63 Expansion Ports 63 Communication Ports 64 Environmental 64 Battery 65 Calendar Clock 65 Agency Qualifications 66 A2 Troubleshooting 67 Power up 67 Pocket Internet Explorer 67 Phys...

Страница 9: ...re attractive The 6 QuickPanel View Keypad is an all in one microcomputer designed for maximum flexibility The design based on an advanced XScale microprocessor brings together a high resolution touch screen operator interface with a variety of I O options With many standard ports and expansion busses from which to choose you can connect to most industrial equipment The QuickPanel View Keypad is e...

Страница 10: ... damage to equipment ensure that the DC supply is disconnected from power and that the leads are not energized before attaching them to the unit s power supply plug To connect a DC power supply 1 Using the three screw terminals shown in the following diagram attach a 24VDC 48W power supply to the plug supplied with the QuickPanel View Keypad see specifications on page 61 for conductor size require...

Страница 11: ... To skip running any programs included in the StartUp folder tap Don t run StartUp programs The splash screen disappears automatically after about 5 seconds The Windows CE desktop then becomes visible 3 Tap Start point to Settings and then tap Control Panel 4 In the Control Panel double tap Display to configure the LCD display see page 28 5 In the Control Panel double tap Stylus to configure the t...

Страница 12: ...ss or touch screen sensitivity or do not want to save the changes remove AC power from the 24VDC supply 3 To save changes to operating system settings e g brightness touch screen sensitivity run Backup see page 16 and run Reboot see page 17 When the Windows CE desktop reappears remove AC power from the 24VDC supply P a n e l C u to u t For enclosure mounting cut an opening in the panel according t...

Страница 13: ...g the operational temperature limits These considerations could include shading for the QuickPanel and its cabinet with awnings or other solar opaque materials avoiding a due East or West facing of the cabinet ventilation or active cooling of the cabinet or other methods The unit will not fit through this cutout with a CF card inserted in the port with any cables connected or with the power supply...

Страница 14: ...unting clamps hold the unit in place by tension alone No drilling is required Do not damage the gasket attached to the back of the QuickPanel View Keypad s bezel This gasket prevents shock hazards and damage caused by liquids accidentally entering the unit after installation ...

Страница 15: ...GFK 2357A 6 QuickPanel View Keypad 7 We l c o me Getting Started ...

Страница 16: ......

Страница 17: ...ction 14 To configure a LAN connection 15 To configure a Proxy server 15 Backup 17 To run the Backup program 17 Reboot 18 To reboot the system 18 Storage Manager 19 System Information 19 To run the System Information program 19 Microsoft File Viewers 20 To access the Microsoft file viewers 20 Copy Project to Flash Card 21 To copy a Machine Edition project onto a CF card 21 To update a Machine Edit...

Страница 18: ... switches and battery The following diagram shows the physical layout of the QuickPanel View Keypad and the locations of ports and connections Caution Remove power from the QuickPanel View before opening the back Working on a live unit may result in damage to equipment and injury to personnel Always use anti static precautions i e grounded wrist strap when accessing the interior of the unit Do not...

Страница 19: ...View Keypad 11 LEDs Touch screen LCD display See page 28 Power supply socket See page 2 Hinged access cover for expansion see page 49 and battery see page 56 Not to scale Bottom Ethernet port See page 45 RS232 485 port COM1 See page 38 Front Right Side CF Port See page 44 ...

Страница 20: ... k Di ag r am The 6 QuickPanel View Keypad is based on the XScale microprocessor and employs large scale integration to provide high performance with a small footprint The following block diagram illustrates the major functional areas of the QuickPanel View Keypad and the interfaces between them ...

Страница 21: ...ing system starts automatically following a power up or reset of the QuickPanel View Keypad For more on Windows CE visit www microsoft com windows embedded windowsce default mspx W o rk i n g w i t h W i n do w s C E When working with Windows CE on the QuickPanel View Keypad user input is achieved via the touch screen with a stylus or other suitable pointing device and via the intergrated keypad s...

Страница 22: ...eb pages and download from FTP sites Pocket Internet Explorer supports JScript Java support can be added from third party sources Pocket Internet Explorer does not support VBScript however VBScript components are included in the operating system and may be used by third party applications such as Proficy Machine Edition A connection can be established over an Ethernet network or a dial up connecti...

Страница 23: ...t 4 Tap OK 5 To save the settings run Backup see page 16 To configure a LAN connection 1 Start Pocket Internet Explorer 2 From the Tools menu choose Options TheInternet Options dialog box appears 3 On the Connection tab select the Use LAN check box 4 Tap OK To save the settings run Backup see page 16 To configure a Proxy server 1 Start Pocket Internet Explorer 2 From the Tools menu choose Options ...

Страница 24: ...ngs run Backup see page 16 Ba ck u p Backup saves changes that you make to the Windows Registry or Desktop to Flash memory This utility is required because the QuickPanel View Keypad is not battery powered Specifically Backup does the following It stores the Windows CE registry including any control panel settings in Flash memory It stores any changes or additions made to the Windows subtree of th...

Страница 25: ...n of the Windows CE operating system then restarts the QuickPanel View This ensures all open files are closed properly To reboot the system 1 To save changes to system configurations run Backup see page 16 2 Tap Start point to Programs then the System folder and tap Reboot A confirmation dialog box appears 3 Tap Yes The operating system reboots ...

Страница 26: ...on line help is available S y s t e m I n f o r m a t i on System Information is a custom utility that displays a splash screen with the following information Operating System version For example Windows CE 5 00 Platform Identifies the host hardware its version and build number Tapping More Info on the splash screen opens the Advanced System Information window which provides information such as ha...

Страница 27: ...ox appears The system copies the project onto the blank CF Card To update a Machine Edition project You can update a Proficy Machine Edition application currently stored on the QuickPanel View Keypad with a revision stored on a CF Card 1 Insert the CF Card containing an upgraded version of the Machine Edition project in the CF port 2 Reboot the machine see page 17 When a valid project is found on ...

Страница 28: ... i e w QuickPanel View Keypad Software 20 6 QuickPanel View Keypad GFK 2357A 2 2 Start the ActiveSync session When installation of third party software is complete close the dialog box to deactivate Emulate PPC ...

Страница 29: ...m The HTTP utility currently supports two file transfer commands COPY and DELETE Note In order to function the HTTP File Transfer utility requires both computers to have web servers that support PUT functionality Most web servers support PUT including the Proficy Machine Edition web server installed with the runtimes for View and Logic Developer PC If in doubt check the documentation for your web ...

Страница 30: ...e called MyFileBACKUP txt from the webfiles directory under the web server at HTTP MyServer F TP S er v e r The FTP Server included with the QuickPanel View supports both standard RFC 959 and Explicit FTPS i e FTP SSL Auth TLS TLS C RFC 4217 It does not support SFTP or implicit FTPS which uses different ports and is based on SSH rather than SSL All configuration of the FTP server is accomplished w...

Страница 31: ...e server to have a signed server certificate it can use to prove it is the actual machine the client wanted to reach and not an imposter This mode is active when both Support Secure Connection and Required are enabled By default the server requires a username password combination to be configured The server supports one username password combination to authenticate remote users There are three mod...

Страница 32: ... inserted it will still work provided the CF card s device name did not change during reinsertion A server certificate is a special type of document which contains information about the server s settings and a chain of electronic signatures to guarantee the document has not been altered A Server certificate must be chosen from the certificates available in the QuickPanel View Secure FTP Server con...

Страница 33: ... can be transferred to FTP Clients as a trusted source Certificates may be managed through snap in s to the Microsoft Management Console or other third party management consoles A Backup should be performed after configuring the FTP server and or creating the self signed certificate To install a certificate on an FTP Client 1 Double click the certificate Select the General Tab The Certificate prop...

Страница 34: ......

Страница 35: ...41 To add a virtual private network or PPP over Ethernet 42 To change the default device properties 44 To change the default TCP IP settings 44 CF Port 45 Ethernet 46 To set an IP address 47 To set up access to a Windows network 48 To access a remote resource on a Windows network 48 Expansion Bus 50 DIP Switches 51 To configure startup behavior 52 Memory 53 To add Flash memory with a CF Card 53 To...

Страница 36: ...s 320 x 240 pixels and it supports a maximum of 65 536 colors 256 colors simultaneously A timer feature lets you configure the backlight to turn off automatically thus extending its life To adjust the display contrast 1 In the Control Panel double tap Display and choose the Contrast tab The Contrast dialog box appears 2 Drag the Contrast slider between Lowest and Highest 3 Tap OK to exit the contr...

Страница 37: ...pad 29 To configure backlight auto turn off 1 In the Control Panel double tap Display and choose the Backlight tab The Backlight dialog box appears 2 Select Auto turn off backlight while on external power 3 Tap OK to exit the control panel 4 To save the settings run Backup see page 16 ...

Страница 38: ... View Keypad is properly calibrated this translates into a grid of touch cells on the face of the display Although you can use your finger to actuate the touch screen use of a blunt stylus is recommended To calibrate the touch screen 1 In the Control Panel double tap Stylus The Stylus Properties dialog box appears 2 Choose the Calibration tab 3 Tap the Recalibrate button A cross hair target is dis...

Страница 39: ...ections given to calibrate the touch screen 5 Tap the screen to preserve the new setting or wait out the time limit to revert to previous settings 6 To save the settings run Backup see page 16 To set the double tap sensitivity 1 In the Control Panel double tap Stylus The Stylus Properties dialog box appears ...

Страница 40: ...pad GFK 2357A 3 2 Choose the Double Tap tab 3 Double tap the grid to enter a setting 4 Double tap the test icon to check the setting If the test icon doesn t change when you double tap it double tap the grid again 5 Tap OK to finish 6 To save the settings run Backup see page 16 ...

Страница 41: ...troke Example topic in Machine Edition Online Help K ey p a d O p e ra t i o n In general the keys report and operate in the same manner as those on a standard keyboard but note the following An additional 14 programmable Function keys have been added to the standard 12 as well as an additional 8 programmable guitar pick keys Function keys are enabled by default Pressing Fn enables the lower case ...

Страница 42: ...e function alpha keypad and on the numeric keypad If Fn is not active the function keys report as F1 through F26 and the numeric keys report as 0 to 9 the decimal point and the minus symbol If Fn is active the keys report as the labels on their upper right indicate For a list of keyboard operating system shortcuts see page 13 To enable and disable the alternate character set on the keypad Press an...

Страница 43: ...erator date input device An icon in the system tray lets you view or hide the SIP To show hide the Soft Input Panel On the system tray of the task bar double tap the icon The Soft Input Panel appears disappears Note When the SIP is visible it can be dragged around the screen by its title bar to reveal different parts of the screen that would be obstructed from view by the SIP Show Input Panel icon...

Страница 44: ...el in system tray check box 4 Tap OK 5 To save the settings run Backup see page 16 The Soft Input Panel provides a standard QWERTY key layout with numeric keys at the top row as illustrated in the following picture Uppercase characters are accessed by pressing the SHIFT key once This is equivalent to holding down the SHIFT key on a conventional keyboard The SHIFT key is active while the next key i...

Страница 45: ...he CTRL and ALT keys behave the same as the SHIFT key To reset SIP location In the event the user accidentally drops the SIP off screen and can t drag it back on screen the following steps will reset the SIP to the centre of the screen 1 In the Control Panel double tap Input Panel The Input Panel Properties dialog box appears 2 Select Reset SIP location Upper Case SIP ...

Страница 46: ...ing table Note Pin 14 is fused with a field replaceable 1 0A fast blow fuse R e co m m e n de d C a b l i n g f or T I A E I A 42 2 or T I A EI A 48 5 The COM1 port on the QuickPanel View provides connections to devices which support either TIA EIA422 or TIA EIA485 These electrical standards specify a differential signaling technique which provides high data rates long distances and good noise rej...

Страница 47: ...ansmitting and receiving devices must be provided This return path is separate from the Rx and Tx data lines and the other 422 485 signals supported by the QuickPanel View and may be provided by a separate conductor in the cable Connect both ends of the signal return conductor to Signal Ground pin 7 Shielding or use of a twisted pair for this connection is not necessary For installations where all...

Страница 48: ... used for attaching the cable shield in these applications Caution Do not connect Signal Ground pin 7 to Frame Ground pin 1 on the QuickPanel View Keypad except in the specific and limited circumstances noted in the Grounding section above W o rk i n g w i t h t he C O M p or t To add a new remote networking connection 1 From the Start menu tap Settings and then Network and Dial up Connections The...

Страница 49: ...for direct connection Device dialog box or Next for dial up Modem dialog box If you are adding a dial up connection the following dialog box appears 8 Type the destination Country region code Area code and Phone number in the appropriate boxes 9 Select or clear the Force Long Distance or Force Local check boxes 10 Tap Finish 11 To save the settings run Backup see page 16 To add a virtual private n...

Страница 50: ...Private Network to configure a VPN connection Select PPP over Ethernet for a PPPoE connection 5 Tap Next The VPN or PPPoE Connection window appears depending on the connection type 6 Enter the Host Name or IP address for a VPN connection or a PPPoE Service Name for a PPPoE connection You can configure your TCP IP Settings at this time if you wish 7 Tap Finish 8 To save the settings run Backup see ...

Страница 51: ...uickPanel View Keypad to emulate a terminal attached via a modem link Hayes compatible to COM1 A terminal emulation definition is added as a unique session 4 To save the settings run Backup see page 15 To change the default TCP IP settings 1 Obtain correct TCP IP settings from your network administrator 2 From either the Device Modem PPPoE Connection or VPN Connection dialog box tap TCP IP Setting...

Страница 52: ...ce it The Copy Project to Flash Card utility see page 19 lets you transfer Proficy Machine Edition projects between QuickPanel View Keypad units via CF Cards No Compact Flash cards are supplied with the QuickPanel View Keypad A list of cards and other devices that have been tested and are compatible can be found by visiting http www ge ip com support then select the Operator Interface category the...

Страница 53: ...st Configuration Protocol Using this method uniquely specify the numeric addresses for the QuickPanel View the Subnet Mask and the Default Gateway if applicable Note There must be a DHCP server on the connected network for a valid IP address to be assigned Contact your network administrator to ensure correct DHCP server configuration Manual method Using this method uniquely specify the numeric add...

Страница 54: ...via DHCP automatic Specify an IP address manual 4 Enter the IP Address Subnet Mask and Default Gateway numbers obtained from your network administrator manual method only 5 Tap OK 6 To save the settings run Backup see page 16 If the DHCP method was selected the network server will assign an IP address while the QuickPanel View Keypad is initializing You must be connected to the network After setti...

Страница 55: ...our QuickPanel View Keypad In the Device description box type a description 3 Tap OK 4 In the Control Panel double tap Owner The Owner Properties dialog box appears 5 On the Network ID tab type your assigned User name Password and Domain 6 Tap OK 7 To save the settings run Backup see page 16 Using Windows CE Explorer you can now access anything on your local network for which you have permission T...

Страница 56: ...yFolder specifies the folder named MyFolder on a computer with the name MyRemoteComputer 3 Press ENTER The resource specified is displayed as a collection of files and folders It can take a few moments to retrieve the data from your local network Note You can use the NET command from the shell to map a network resource to the QuickPanel View Keypad for frequent access The resource then appears in ...

Страница 57: ... screws must be used when installing an expansion card Caution Disconnect the AC power from your 24 VDC power supply before opening the QuickPanel View Keypad Working on a live unit may result in damage to equipment and injury to personnel Always use anti static precautions i e grounded wrist strap when accessing the interior of the unit Do not allow conductive material liquid or solid to contact ...

Страница 58: ...itch is set to OFF the QuickPanel View Keypad operates normally displaying the startup splash screen You can skip running the startup applications by tapping the Don t run StartUp Programs button on the startup splash screen When the switch is set to ON the startup programs are forced to run and the Don t run Startup Programs button is not available on the startup splash screen Note Do not adjust ...

Страница 59: ...age to equipment and injury to personnel Always use anti static precautions i e grounded wrist strap when accessing the interior of the unit Do not allow conductive material liquid or solid to contact the electronics of the QuickPanel 1 Open the back cover of the QuickPanel View Keypad 2 Locate the DIP switches and set DIP switch 2 to ON The startup applications are now forced Note Do not adjust t...

Страница 60: ... utility is run FLASH memory has a limited write cycle lifetime That is the physical memory devices wear out after approximately 100 000 cycles minimum so it is advisable to limit file operations such as copy delete etc The write cycle is much slower for FLASH than it is for other portions of RAM therefore FLASH is not recommended for the storage of program variables or any data items whose values...

Страница 61: ...tions The other 18 8 MB is split between two functions an object store for temporary file storage and the main memory for running programs Typically compressed programs stored in FLASH are expanded and moved to DRAM for execution Temporary storage of program variables or data files is also provided by DRAM any data stored in DRAM will not be retained through a power cycle or reboot The split betwe...

Страница 62: ...provides 512 KB of non volatile storage for the QuickPanel View Keypad s initialization program This program configures the QuickPanel View Keypad hardware then starts the operating system s execution This memory is not accessible from Windows CE Explorer nor should any attempts be made to modify the contents of this ROM M em or y E xp an s i on S l o t The QuickPanel View Keypad is equipped with ...

Страница 63: ...ct the electronics of the QuickPanel To install additional DRAM 1 Disconnect AC power from the 24VDC supply 2 With a small screwdriver carefully remove the top rear access cover 3 Insert the new DIMM carefully into the expansion slot noting the orientation of the pin locators When the DIMM is fully seated lift each side clip until it clicks into place 4 Snap the access cover back into place ...

Страница 64: ...ower for the real time clock and SRAM is provided by a non rechargeable internal lithium battery 3VDC BR2032 ensuring that no loss of data occurs when the main 24VDC supply is removed Backup power is enabled or disabled by installing or removing the battery accessed via the rear panel as shown in the following illustration Caution Disconnect the AC power from your 24VDC power supply before opening...

Страница 65: ...Year Month Day Hour Minute Second The time is set from the Windows CE interface and retained through a power cycle if battery backup is available Daylight saving time is enabled by a check box within the dialog box The time can be displayed in the system tray on the task bar To set the real time clock 1 In the Control Panel double tap Date Time The Date Time Properties dialog box appears Note Tap ...

Страница 66: ...me servers are intended for general SNTP time service needs and usually enable public access It is recommended that you use second level time servers for normal SNTP time server configuration because they are normally located on a closer network that can produce faster updates It is recommended that you research any time server selection to ensure that it can meet your specific time server require...

Страница 67: ...s Note Tap Update Now after making changes in any box 2 To add or modify SNTP settings select the SNTP tab 3 To enable SNTP ensure the Enable SNTP check box is selected 4 Enter the time server name in the Server s field 5 Set the Refresh Retry and Threshold parameters 6 Tap Update Now to update SNTP settings immediately 7 Tap OK to finish 8 To save the settings run Backup see page 16 ...

Страница 68: ......

Страница 69: ...5 in 301 1 mm Depth 2 37 in 60 1 mm Bezel dimensions Height 10 34 in 262 6 mm Width 13 26 in 336 8mm Depth 0 38 in 9 7 mm Weight 5 2lb 2 36 kg Input Voltage 12 VDC 20 regulated power supply or 24 VDC 20 regulated power supply Power Dip Tolerance 30 nominal input voltage 10msec Insulation Resistance 200 Mohm 1000V frame ground to 0V 200 Mohm 1000V frame ground to 24V Real Power 24 W 24 Vdc Power Su...

Страница 70: ... X 240 Fabrication Passive STN Transmissive Backlight Cold Cathode Fluorescent CCFL rated half life 40 000 hours1 Luminance 150 NITs Bezel Material Valox 37062 Membrane Material Lexan HP60 3 LEDs Bottom Top Power status indicator green with power applied flashes amber if both backlights fail Programmable tri color green red amber Material AutoFlex EBA10 polyester2 Activation force 13 oz 2 oz Lifet...

Страница 71: ...00 pin DIMM Memory Type SDRAM Maximum DRAM 64 MB Maximum Devices Module 4 Bus Width 32 bits Bus Speed 100 MHz or faster Voltage 3 3 VDC CAS Latency CL 3 Refresh Type Self Refresh Cycle Time 64 ms maximum Error Correction Non ECC Error Detection No parity Buffering None Device Row Addressing 12 Address Lines A0 to A11 Expansion Memory Catalog Number 32 MB IC754ACC32MEM 64 MB IC754ACC64MEM Compact F...

Страница 72: ...exposure Ethernet IEEE 802 3 10BaseT 100BaseTX Auto negotiate Full or half duplex RJ45 connector Two status LEDs Maximum cable length 30M Serial COM1 Speed Mounting h w Fuse EIA232C EIA485 DP25S female 300 bps 115200 bps M2 6 jackscrew 1 0A 125V fast blow cartridge type Littlefuse part 154001 Operating Temperature 32 F to 122 F 0 C to 50 C Operating Humidity 10 to 85 RH non condensing Storage Temp...

Страница 73: ... c a t i o n s GFK 2357A 6 QuickPanel View Keypad 65 Ba t t er y C a l e n d a r C l o ck Type BR2032 3V 190 mAh lithium Life Approximate 5 years Resolution 1 second Accuracy 2 to 3 minutes per month Retention Life of battery ...

Страница 74: ...ndard and equivalent CSA standard Explosive Atmospheres Directive European Safety for Hazardous Locations Equipment Group II Category 3 ATEX when mounted in an IP66 rated panel Certification in accordance with European directives refer to Declaration of Conformity and Independent 3rd Party Assessment Certificate Low Voltage Directive European Safety for Industrial Control Equipment CE Self declara...

Страница 75: ...ions to the QuickPanel CE Backlight failed This is further indicated when the bottom LED glows amber The LED will only light if both top and bottom backlights have failed Backlight timer expired Touch screen to reactivate Problem Suggested remedy Cannot access any URLs when using a dial up connection to an ISP If you have previously set up an IP address on a local Ethernet Network it must be clear...

Страница 76: ...leading to delayed response to touch inputs Corrupted external flash drives may be corrected with Storage Manager See Storage Manager on page 18 After adding expansion memory in the DIMM connector the system won t boot or if it does boot an error message is displayed When the system is first started observe the screen to notice any memory error messages from the boot loader If any messages appear ...

Страница 77: ... 47 cutout 4 see also design specificatons D design specifications 61 device properties configuring 43 DHCP Dynamic Host Configuration Protocol 45 dial up connection 40 dip switches 50 displaying real time clock 58 double tap sensitivity setting 30 31 DRAM 53 partition DRAM memory 53 partitioning 53 E Emulate PPC 19 Ethernet 45 port settings 46 expansion bus 49 expansion busses locations 10 expans...

Страница 78: ...achine Edition 14 19 44 programs start menu 14 proxy server 15 R real time clock 57 displaying 58 setting 57 59 reboot 17 S serial ports 38 setting double tap sensitivity 31 sensitivity 30 IP address 46 real time clock 57 59 setup basic 2 runtime 3 shutdown 4 specifications 61 to SRAM 53 start menu 14 startup 3 configuring behavior 51 force startup switch 50 stop startup programs 50 storage card 5...

Отзывы: