ADJUSTABLE FEATURES
IT TRANSISTOR CONTROLS
Page
39
October 2007
4. Use the table below to determine the appropriate
setting using the calculated V
Drop
as a reference.
INTERNAL RESISTANCE COMPENSATION
TABLE
Setting V
Drop
Setting V
Drop
2 11.44 17 01.34
3 07.60 18 01.27
4 05.72 19 01.20
5 04.57 20 01.14
6 03.81 21 01.09
7 03.27 22 01.04
8 02.86 23 00.99
9 02.54 24 00.95
10 02.28 25 00.91
11 02.08 26 00.88
12 01.90 27 00.85
13 01.76 28 00.82
14 01.63 29 00.79
15 01.52 30 00.76
16 01.43 31 00.74
FUNCTION 15 BATTERY VOLTS
(Push
l5)
This function allows for the adjustment of voltage range
for controls equipped with the Battery Discharge
Indication function. In order for the BDI to operate
properly, the setting as shown in the table must be
entered:
Battery volts
Set units
24 volts
Between 0 and 31
36 volts
Between 32 and 44
48 volts
Between 45 and 69
72 volts
Between 70 and 80
80 volts
Between 81 and 183
36/48 volts
Between 184 and 250
No BDI
Between 251 and 255
FUNCTION 16 GEAR RATIO
( Push CONT 1)
This function allows for the adjustment of transmission
gear ratio.
Range
0 to 255
Setting
0
to
255
Resolution 0.1
Example
GR = 12.4 / 0.1 = 124
Set
Value
124
FUNCTION 17 FIELD GAIN
( Push CONT 2 )
This function allows for the adjustment of the pedal up
field gain. This value is determined by GE application
engineering and should be set using the OEM setting
specifications for this vehicle.
FUNCTION 18 LINE CONTACTOR COIL VOLTAGE
(Push CONT 4)
this function sets the voltage level at which the line
contactor and brake coils are held.
Range
0 to 96 volts
Setting
0
to
255
Resolution
0.377 volts per set unit
Voltage = SETTING VALUE / 2.65
FUNCTION 19 PEDAL DOWN/BRAKE REGEN RATE
(Push
CONT
4)
This function allows for the adjustment of the rate at which
speed is reduced during regenerative braking under
speed regulation.
Range
0.1 to 25.5 seconds
Set
0 to 255
Resolution
0.086 seconds per set unit
Example:
Setting of 20 = 1.72 seconds
Setting of 1 = Most aggressive braking
Setting of 255 = Least aggressive braking
FUNCTION 20 PEDAL UP REGEN RATE
(Push CONT 5)
This function adjusts the rate at which speed is reduced
during regenerative braking when the accelerator pedal is
released and start switch opens or the control receives a
directional change signal.
Setting 1 to 255
Setting of 1 = Most aggressive braking
Setting of 255 = Least aggressive braking
FUNCTION 21 TOP SPEED REGULATION
(Push CONT 6)
This function adjusts the top speed regulation point of the
vehicle.
Range
0 to 63.75mph
Setting
0 to 255
Resolution 0.25mph per set unit
Example
Setting of 100 x 0.25 = 25mph