26
I. TROUBLESHOOTING
Area Problem/Situation
Corrective
Action/Remedy
General
A part is missing
Contact Homespring Consumer Products Customer Service
Purchase part (most standard hardware parts) from local hardware store
System leaks water
Tighten System Cap
Check O-ring is in place, is clean and is intact
Ensure connections are tight
Replace broken part from an over tightened connection
Rewrap thread connections with new Teflon tape. Do not reuse Teflon tape.
System water flow is noticeably
reduced
Check if Thimble Filter is clogged. Depressurize System, remove System Cap and
Internal Prefilter, remove Thimble Filter using a pair of needle nose pliers, clean Thimble
Filter and Reinsert Thimble Filter
Check if External Prefilter is clogged, if installed. Refer to
L. REPLACEMENT PART LIST
AND PROCEDURE
Check if Internal Prefilter is clogged. Refer to
L. REPLACEMENT PART LIST AND
PROCEDURE
Check Trans Membrane Pressure and perform a cleaning if necessary as described in
G. ANNUAL MAINTENANCE
Check if Drain Solenoid Valve functions. A malfunctioning valve will increase the rate of
the membrane fouling. Refer to Controller Functions section under E. INSTALLATION
INSTRUCTIONS, initiate a manual flush and verify Drain Solenoid Valve is working.
Replace valve if necessary
Water does not flow through System
Black cap on Air Vent must be backed off by 1.5 turns from tight to allow air in and our
of System
If the Optional Surface Water Option Kit is installed, check if Inlet Solenoid Valve is in the
normally open position. Using the Controller, initiate a manual flush sequence while
simultaneously pressing the down arrow and hold for a full 5 seconds. Refer to
Controller Functions section under
E. INSTALLATION INSTRUCTIONS
on how to
perform a manual flush sequence. A buzz sound should be heard from the Inlet
Solenoid Valve. Replace Valve if necessary
Checking
Backpulse Tank
Pressure
Pressure is too HIGH (greater than 35
psi)
Release air from the Air Bladder Valve on the Backpulse Tank by gently pushing in the
valve stem
Pressure is too LOW or NO pressure
(less than 30 psi when unboxed
Add air using a compressor or hand pump. Check the pressure again in 15 minutes and
before leaving the site. If pressure is lost, replace Backpulse Tank
Connecting Pipe
Assemblies
Parts are cross-threaded
Undo connection, add Teflon tape and slowly thread the 2 parts together. If threads are
stripped, replace the part(s)
Leak is detected
Tighten connections
Loosen connections that are too tight
Reinstall the part with Teflon Tape
Air Relief Valve
Water spouts from top
Replace Air Relief Valve (Duo Vent)
System Cap
Removal
System Cap does not loosen
Close Inlet Valve and depressurize the System. Refer to
Controller Functions
section
under E.
INSTALLATION INSTRUCTIONS
to initiate a manual flush
External Prefilter
Water does not flow through
Press RED button on top of housing to release air until water flows from button as air
may be trapped in housing
Replace External Prefilter Cartridge if water pressure has been gradually decreasing as
the External Prefilter may be plugged or fouled. Refer to
L. REPLACEMENT PART LIST
AND PROCEDURES
Does not drain fast enough
Depress red button on housing to drain quickly
Water leaks from bottom
Check Mini Ball Valve on bottom of housing. Close tightly
Drain Solenoid
Valve
Does not open to allow flushing
Using the Controller, initiate a manual flush sequence. Refer to Controller functions
section under E. INSTALLATION INSTRUCTIONS on how to perform a manual flush
sequence and ensure button on controller is pressed for a full 5 seconds. A buzz sound
should be heard from the Drain Solenoid Valve. Replace valve if necessary
Check connections are installed correctly and transformer is plugged in
Inlet Solenoid
Valve
Does not close to allow System to drain
On the Controller, press NEXT once. Simultaneously press MANUAL FLUSH and the
down arrow together and hold for a full 5 seconds. A buzz sound should be heard from
the Inlet Solenoid Valve. Replace valve if necessary
Check connections are installed correctly and transformer is plugged in
Controller
Flushing and/or draining of System
does not work
Check if the Drain Solenoid Valve functions. Check connection to Controller is correct
and initiate a manual flush to hear a buzz sound. Refer to
Controller Functions
under
E. INSTALLATION INSTRUCTIONS
Check if both the inlet Solenoid Valve, if installed, and the Drain Solenoid Valve function
properly. On the Controller, press NEXT once. Simultaneously press MANUAL FLUSH and
the up arrow together and hold for a full 5 seconds. A buzz sound should be heard from
both the Inlet Solenoid Valve and the Drain Solenoid Valve. Replace valve(s) if necessary
Check connections to Controller are correct for the Drain Solenoid Valve and
Transformer and if applicable the Inlet Solenoid Valve
Check if the transformer is connected and plugged in