22
Generator AC Connection System
A single-phase, three-wire AC connection system is used in
the home generator. The stator assembly consists of a pair
of stationary windings with two leads brought out of each
winding. The junction of leads 22 and 33 forms the neutral
lead, as shown schematically and as a wiring diagram. A
complete schematic and wiring diagram can be found later
in this manual.
NOTICE
Neutral is not bonded to ground at generator.
The conduit
A
between the corner electrical inlet and the
control panel is a UL requirement. If removed, it must be
replaced with similar conduit.
33
240V
11
22
44
120V
120V
11
22 33
44
0
Neutral
Power W
inding
Circuit
Breaker
Line 1
Neutral
To Transfer Switch
Line 2
Ground
Circuit
Breaker
Ground the home generator per applicable codes, standards,
and regulations. The generator GND lug is located inside the
control panel box.
Grounding the Generator
A
Not
for
Reproduction