2-8
MDS Intrepid-HC HP Installation and Operation
Or click the up/down arrows in the TX Channel field to select the channel (the frequency will be updated
accordingly).
For the
Frequency Control
area, note the following:
Only one standard is generally shown, predetermined by the ODU parameters. When the standard is unknown,
the
TX Channel
field will be disabled.
TX Channel
selection is possible only when a predefined standard file was installed. In some cases, you may
be able to select more than one standard.
The
Rx Frequency
field is read-only for systems other than 6, 7, 8, 10, and 11 GHz.
The arrow on the right side in the Frequency Control area is green when communication exists between the
local and remote units. If there is no communication between the units, the arrow is red.
4. Select
the
XPIC Enabled
option if you want to activate the XPIC mechanism.
With The transceiver operating in co-channel dual polarization (CCDP) mode, using the cross polarization
interference canceller (XPIC) algorithm, two STM-1 signals can be transmitted over a single 28 MHz channel,
using vertical and horizontal polarization. This enables double capacity in the same spectrum bandwidth.
Note:
Setting XPIC for the right drawer will effect the left drawer as well, and vice versa.
5. Select
Local Only
if you want to frequency changes to affect only the local unit. Select
Local + Remote
if you
want frequency changes to affect the remote unit as well.
Note:
If there is a communication failure between the local and remote units, the Local + Remote option will be
disabled.
6. In
the
Transmitter Configuration
area, select
TX Mute
to block transmission to the remote unit. By default,
this option is not selected.
Select
ATPC
to activate the Automatic Transmit Power Control feature.
For
Set TX Level
, enter or select the designated signal level. Possible range is -10 to max power level. By
default, the transmit signal level is set to the maximum power level.
The
Monitored TX Level
field (read-only) displays the system's transmitted power level.
7. In
the
Receiver Configuration
area, the
Set Reference Rx Level
field should be set to the Rx level to which
the actual level will be compared. This field is active only if ATPC is enabled.
Receiver Mode
is the Rx path, which can be set to Main, Diversity, or Combined. This field appears only if
IFC (IF Combiner) is supported.
RSL Connector Source
can be Diversity or Main. This field appears only if XPIC is not supported and IFC is
supported.
The
Monitored Rx Level
(Main)
field is read-only and displays the received power level.
Monitored Rx Level (Diversity)
is a read-only field that displays the received power level of the Diversity
channel.
8. Click
Apply
to save the settings.
9. Click
Close
.
Содержание HC HP
Страница 2: ......
Страница 6: ......
Страница 42: ...GE MDS Intrepid HC HP Installation Guide 1 36 ...
Страница 98: ...A 6 GE MDS Intrepid HC HP Installation and Operation ...
Страница 100: ...B 2 GE MDS Intrepid HC HP Installation Guide ...
Страница 114: ...GE MDS LLC Rochester NY 14620 General Business 1 585 242 9600 FAX 1 585 242 9620 Web www GEmds com 175 Science Parkway ...