background image

About the water filtration system.

Using the Water Filtration System and About the Filter Cartridge

The countertop faucet dispenses filtered drinking water when opened. 
It has a hand-operated, spring-loaded closed lever to prevent waste. You can
keep the faucet open by pushing upward on the lever to lock it against the
faucet spout.

Filter Cartridge Life – 

Several variables determine how long the cartridges 

will last in your Water Filtration system. These include:

How much water you use.

How much sediment, taste and/or odor, lead or other unwanted substance 
is in the water.

No matter which Water Filtration system you have, you should replace the
cartridges every six months, when indicated by the electronic indicator light
on the base. In extremely poor water supplies, you may notice the return of 
the unwanted substance in your water before the six months are up. In this
case the cartridges should be replaced immediately. If the system is also for
lead or chemical contaminant removal, it is 

MORE IMPORTANT 

to replace the

cartridges at least every six months.

NOTE: 

If the water supply contains high amounts of sediments, the carbon

filters may plug prematurely, reducing filtered water flow to the system faucet.

Cartridge replacement is needed to restore flow.

Electronic Indicator Light (GXSV10C only) – 

The electronic indicator light on the

base of the faucet is a six-month timer that shows you when to replace the
filter cartridges. When the battery pack is first installed, the indicator light will
light briefly to show that the electronics are operating. If this does not happen,
the batteries may be installed backwards or the lead wires are not connected.

After about six months, the indicator light begins to flash. It is time to replace
the filter cartridges. When replacing the filter cartridges, also replace the
batteries in the battery pack. Two AA batteries are required.

2

1

Filtered water faucet

Open

Indicator light

Lock
open

4

Содержание GXSV10C

Страница 1: ...Cyst Turbidity Asbestos and VOC Safety Information 2 Operating Instructions 3 4 Specification Guidelines 3 Using the System 4 Installation Instructions 5 11 Battery Pack Installation 8 Faucet Install...

Страница 2: ...NG For your safety the information in this manual must be followed to minimize the risk of property damage or personal injury SAFETY PRECAUTIONS Check with your local public works department for plumb...

Страница 3: ...uces filterable cysts such as cryptosporidium and giardia Reduces Lindane a pesticide 0 5 1 micron nominal particulate reduction For Model GXSV10C FXSVC rev 2 Filter Set 600 Gallon Capacity Filter I W...

Страница 4: ...this case the cartridges should be replaced immediately If the system is also for lead or chemical contaminant removal it is MORE IMPORTANT to replace the cartridges at least every six months NOTE If...

Страница 5: ...screwdrivers Pliers and adjustable jaw wrench Hand or battery powered drill and 1 4 bit saddle valve installation Electric drill and drill bit to drill 1 1 1 4 hole type as required if mounting hole...

Страница 6: ...se plumbing code 248 CMR of the Commonwealth of Massachusetts Turn off the cold water supply and attach saddle valve as shown in illustration at right DANGER To protect yourself from serious injury or...

Страница 7: ...gasket base and large gasket in that order onto the faucet stem Next place lock washer and hex nut onto faucet stud Insert washer into tubing adapter Securely tighten to faucet stud Feed the length of...

Страница 8: ...is held firmly in place Do not overtighten and break the base Assemble the top faucet base and hex nut onto the faucet stud third illustration Tighten the nut until snug Insert tubing insert into tub...

Страница 9: ...the insertion length should be approximately 3 4 of an inch Tubing must be fully inserted to avoid leaks DO NOT REMOVE GRAY COLLET Push the tubing all the way into the fitting until it bottoms out Th...

Страница 10: ...e 3 for a complete list of filter performance characteristics 5 4 3 2 1 Filter I Filter II O ring seal Cartridge Sump II Sump Sump I Label TURN SUMP TO INSTALL TURN SUMP TO REMOVE Head Bracket Turn su...

Страница 11: ...sing to fill Close the filtered water faucet Then check for leaks between the sump and the head NOTE If leaking turn off the water supply and turn on the filtered water faucet Disassemble the filter h...

Страница 12: ...re old installed incorrectly Lead wires damaged Inspect and repair as needed Chlorine taste and or The filter cartridges are no Replace both filter cartridges odor in the product water longer removing...

Страница 13: ...19X10011 HEAD 2 2 0008 WS03X10001 O RING 3 3 8 X 3 5 8 2 2 0009 WS30X10002 SUMP 2 2 0010 WS22X10003 NIPPLE 3 8 NPT X 1 1 2 1 1 0012 WS07X10008 TUBING 3 8 X 20 FT WH 1 1 0015 WS03X10044 TUBING ADAPTER...

Страница 14: ...14 Notes...

Страница 15: ...15 Notes...

Страница 16: ...service you receive from GE contact us on our Website with all the details including your phone number or write to General Manager Customer Relations GE Appliances Appliance Park Louisville KY 40225 R...

Страница 17: ...national selon la norme ANSI NSF no 42 pour la r duction de la concentration de particules classe I la r duction de la concentration de chlore et la suppression des go ts et odeurs et selon la norme n...

Страница 18: ...e manuel pour assurer la s curit et minimiser les risques de dommages mat riels ou corporels MESURES DE S CURIT Consulter le service local des travaux publics au sujet des codes de plomberie L install...

Страница 19: ...ne R duction des spores filtrables comme cryptosporidium et giardia R duction du Lindane pesticide R duction nominale des particules de 0 5 1 micron Pour mod le GXSV10C Filtre FXSVC r v 2 capacit 600...

Страница 20: ...imm diatement remplacer les cartouches de filtration Si le syst me est utilis galement pour l limination du plomb et de contaminants chimiques il est PLUS IMPORTANT de remplacer les cartouches interva...

Страница 21: ...Phillips et lame plate Pince et cl molette Perceuse lectrique ou piles et foret de 1 4 po pour l installation du robinet de prise en charge Perceuse lectrique et foret pour trou de 1 po 1 1 4 po selon...

Страница 22: ...ride sont filet s Robinet d arr t Manette Raccord d adaptation pour tube Douille inerne pour tube Bride Z Utiliser ces pi ces pour le raccordement du tube Utilisation uniquement sur une canalisation m...

Страница 23: ...nt base et grand joint Placer ensuite la rondelle frein et l crou hexagonal sur la tige tubulaire du robinet Ins rer le joint dans le raccord d adaptation du tube Bien serrer sur la tige du robinet Pa...

Страница 24: ...r excessivement pour ne pas briser la base Assembler la base sup rieure du robinet et l crou hexagonal sur la tige du robinet troisi me illustration Serrer l crou pour tablir le contact Ins rer la dou...

Страница 25: ...nviron 3 4 po Le tube doit tre completement ins r pour viter les fuites NE PAS ENLEVER LA VIROLE GRISE Enfoncer compl tement le tube dans le raccord jusqu la position de but e La limite d insertion de...

Страница 26: ...ce des filtres voir la page 19 5 4 3 2 1 Filtre I Filtre II Joint torique Cartouche de filtration Corps de filtre II Corps de filtre Corps de filtre I tiquette FAIRE TOURNER LE CORPS DE FILTRE POUR IN...

Страница 27: ...d ventuelles fuites entre le corps de filtre et la t te de montage NOTE S il y a une fuite fermer l arriv e d eau et ouvrir le robinet d eau filtr e D monter le corps du filtre rechercher d ventuelles...

Страница 28: ...ectriques Inspecter et r parer selon le besoin endommag s Go t et ou odeur de chlore Les cartouches de filtration Remplacer les deux cartouches de filtration dans l eau filtr e ne retiennent plus le c...

Страница 29: ...0001 Joint torique 3 3 8 po x 3 5 8 po 2 2 0009 WS30X10002 Corps de filtre 2 2 0010 WS22X10003 Raccord droit 3 8 po NPT x 1 1 2 po 1 1 0012 WS07X10008 Tube 3 8 po x 20 pi blanc 1 1 0015 WS03X10044 Rac...

Страница 30: ...30 Notes...

Страница 31: ...31 Notes...

Страница 32: ...e Web appareils lectrom nagers GE www GEAppliances com Vous avez une question ou vous avez besoin d aide pour votre appareil lectrom nager Contactez nous par Internet au site www GEAppliances com 24 h...

Страница 33: ...un servicio 44 Servicio del consumidor Garant a Cubierta trasera Lista Cat logo de partes 45 Ayuda al Cliente Cubierta trasera GXSL03C rev 2 est probado y certificado por NSF Internacional contra la...

Страница 34: ...TODAS LAS INSTRUCCIONES ANTES DEL USO Para su seguridad la informaci n en este manual debe ser seguida para minimizar el riesgo de da o a la propiedad o herida personal PRECAUCIONES DE SEGURIDAD Consu...

Страница 35: ...trables tales como cryptosporidium y giardia Reduce el lindano un pesticida Reducci n de part culas nominales de 0 5 1 microne Para modelo GXSV10C Juego de filtro FXSVC rev 2 600 galones de capacidad...

Страница 36: ...n ser cambiados inmediatamente Si el sistema es tambi n para sacar plomo o contaminantes qu micos es MAS IMPORTANTE reemplazar los cartuchos por lo menos cada seis meses NOTA Si la l nea de agua conti...

Страница 37: ...res slotted y Phillips Alicates y llaves inglesas ajustables Taladro y punta de 1 4 manual o a bater a instalaci n de la v lvula tipo saddle Taladro el ctrico y punta para hacer un hoyo de 1 1 1 4 tip...

Страница 38: ...s de las prensas tienen hilos V lvula Manilla Adaptador de tubo Injerto de tubo Prensa Z Use para conectar las ca er as Para un tubo OD de 1 2 o m s grande solamente Instrucciones de instalaci n L nea...

Страница 39: ...la base y la empaquetadura grande en ese orden en el tallo de la llave Luego coloque la arandela de enganche y la tuerca hexagonal en el tallo de la llave Inserte la arandela en el adaptador del tubo...

Страница 40: ...quede firmemente en su lugar No apriete demasiado y quiebre la base Arme la base de la llave de arriba y la tuerca hexagonal sobre el tallo de la llave tercera ilustraci n Apriete la tuerca hasta que...

Страница 41: ...argo de la inserci n deber a ser aproximadamente 3 4 El tubo debe ser completamente conectado para evitar que gotee NO SAQUE EL ANILLO GRIS TIPO COLLET Empuje el tubo hasta el fondo de la uni n La l n...

Страница 42: ...caracter sticas de funcionamiento del filtro 5 4 3 2 1 Filtro I Filtro II Sello tipo anillo Cartucho Recept culo II Recept culo Recept culo I Etiqueta HAGA GIRAR RECEPTACULO PARA INSTALAR HAGA GIRAR...

Страница 43: ...filtro se llene Cierre la llave del agua filtrada Luego revise que no hayan goteras entre el recept culo y la cabeza NOTA Si hay goteras cierre el paso del agua y abra la llave del agua filtrada Desa...

Страница 44: ...instaladas incorrectamente El alambre est da ado Inspecciones y repare como sea necesario Sabor y u olor a cloro Los cartuchos del filtro Reemplace ambos cartuchos de filtros en el agua que se ya no...

Страница 45: ...2 JUEGO DE LLAVE DE BASE 1 0022 WS02X10008 TUERCA 2 0023 WS08X10003 EMPAQUETADURA DE LLAVE 1 0024 WS06X10001 SUJETADOR DE BATERIA 1 0025 FXSLC rev 2 JUEGO DE FILTRO PLOMO QUISTE 1 FXSVC rev 2 JUEGO DE...

Страница 46: ...Notas 46...

Страница 47: ...47 Notas...

Страница 48: ...ase en contacto con nosotros en nuestra p gina Web indicando todos los detalles as como su n mero de tel fono o escr banos a General Manager Customer Relations GE Appliances Appliance Park Louisville...

Отзывы: