background image

Service

When the water softening system is providing soft water, it is called “Service.” During

service, hard water flows from the house main water pipe into the water softening system.

Inside the water softening system resin tank is a bed made up of thousands of tiny, plastic

resin beads. As hard water passes through the bed, each bead attracts and holds the hard

minerals. This is called ion-exchanging. It is much like a magnet attracting and holding

metals. Water without hard minerals (soft water) flows from the water softening system and

to the house pipes.
After a period of time, the resin beads become coated with hard minerals and they have to

be cleaned. This cleaning is called regeneration, or recharge. Regeneration is started at

2:00 AM (factory setting) by the water softening system control, and consists of five stages or

cycles. These are 

FILL, BRINING, BRINE RINSE, BACKWASH

and 

FAST RINSE

.

About the water softener system.

Customer Ser

vice

Tr

oubleshooting T

ips

Installation Instr

uctions

Safety Instr

uctions

Customer Ser

vice

Tr

oubleshooting T

ips

Operating Instr

uctions

Safety Instr

uctions

Customer Ser

vice

Tr

oubleshooting T

ips

Safety Instr

uctions

12

Automatic Hard Water Bypass During Regeneration

For emergency needs, hard water is available

to the home during the regeneration cycles. 

However, you should avoid using HOT water
because the water heater will fill with the 
hard water.

Fill

Backwash 

Salt dissolved in water is called brine. Brine

is needed to clean the hard minerals from

resin beads. To make the brine, water flows

into the salt storage area during the fill stage

as shown.

Brining

During brining, brine travels from the salt

storage area into the resin tank. Brine is the

cleaning agent needed to remove hard

minerals from the resin beads. The hard

minerals and brine are discharged to the

drain.
The nozzle and venturi create a suction to

move the brine, maintaining a very slow rate

to get the best resin cleaning with the least

salt.

Brine Rinse

After a pre-measured amount of brine is
used, the brine valve closes. Water
continues to flow in the same path as during
brining, except for the discontinued brine
flow. Hard minerals and brine flush from
the resin tank to the drain

.

During backwash, water travels 

up

through

the resin tank at a fast flow rate, flushing

accumulated iron, dirt, and sediments from

the resin bed and to drain.

Fast Rinse

Backwash is followed by a fast flow of water

down

through the resin tank. The fast flow

flushes brine from the bottom of tank, and

packs the resin bed.
After fast rinse, the water softening system

returns to soft water service.

Soft water

OUT

Salt storage
tank (salt
not shown)

Brine
valve

Hard water
IN

Resin
tank

Resin
bed

Soft water 

OUT

Hard water 
IN

Salt 
storage 
tank 

Fill 
water

Brine
valve

Hard water

bypass OUT

Nozzle &
venturi

Hard water
IN

Brine
valve

Brine

Drain

Drain

Hard water

bypass OUT

Hard water
IN

Drain

Soft water

OUT

Hard water
IN

Содержание GXSS17Z01

Страница 1: ...GXSS17Z01 GE Appliances Water Softening System Part No 215C1044P003 1 Pub No 49 50007 1 8 98 CG 7196674 Installation and Owner s Manual GE Answer Center 800 626 2000 ...

Страница 2: ... whenever you need quality appliances for your home FOR YOUR RECORDS Write the model and serial numbers here You can find them on the sump bracket Staple sales slip or cancelled check here Proof of the original purchase date is needed to obtain service under the warranty Inside you will find many helpful hints on how to use and maintain your water system properly Just a little preventive care on y...

Страница 3: ...ng with salt WARNING Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Read and follow this Safety Information carefully SAVE THESE INSTRUCTIONS PROPER INSTALLATION Install or store where it will not be exposed to temperatures below freezing or exposed to any type of weather Water freezing in the system will break ...

Страница 4: ...all the Softener section for more details WARNING Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system The water should be tested periodically to verify that the system is performing satisfactorily Small parts remaining after the installation could be a choke hazard Discard safely 4 Installation instructions Customer ...

Страница 5: ...ener must be at least 3 4 size Some local codes require a minimum of 1 pipe size To plumb with 1 pipes buy adapters to fit the 1 pipe threads on the bypass valve see Fig 1 and Fig 2 Use copper brass or galvanized pipe and fittings Some codes may also allow CPVC plastic pipes Use the included bypass valve to install the softener The bypass valve allows you to turn off water to the softener for serv...

Страница 6: ...the 1 threads INLET Brinewell NOTE See Drain Hose Connections section SALT GOES HERE Salt hole cover removed 24V transformer 120 volt outlet Hard water Soft water From softener outlet To softener inlet CROSS OVER Use if water supply flows from the left Include single or 3 valve bypass Hard water Soft water From softener outlet To softener inlet CROSS OVER Use if water supply flows from the left In...

Страница 7: ...coming hard water supply is directed to the softener valve inlet port If house water flow is from the left use a plumbing cross over as shown in Fig 1 If making a soldered copper installation do all sweat soldering before connecting pipes to the bypass valve Torch heat will damage plastic parts When turning threaded pipe fittings onto plastic fittings use care not to cross thread Use pipe joint co...

Страница 8: ...ain fitting so the cutting blade clears the valve housing to prevent damage to valve Buy a compression fitting 1 4 female pipe thread x 1 2 O D tube and needed tubing from your local hardware store Connect and run the cabinet brine tank overflow hose Attach a length of hose use remaining hose from Step 5 to the drain elbow installed in Step 4 Use a hose clamp to hold it in place Locate the other e...

Страница 9: ... or slide the valve stem toward service pausing several times to allow the softener to pressurize slowly This initial flow of water may be rusty colored This is normal and will disappear quickly E After about 3 minutes open a HOT water faucet for 1 minute or until all air is expelled then close F Close all water faucets G Check your plumbing work for leaks and fix right away if any are found Be su...

Страница 10: ... steady the minute display day will begin flashing Fig 9 shows the timer set at 3 30 PM B Set the present day of the week Press the SET CLEAR button to set the present day of the week in the display NOTE Press SET CLEAR button and quickly release to move the day display 1 at a time Or hold the SET CLEAR button to move the day display ahead 2 days each second Press the TIME DAY button again to stea...

Страница 11: ...ear water iron ppm Water pressure limits min max psi Pressure drop at rated service flow psig Water temperature maximum F Water supply minimum flow rate gpm Regeneration cycle flow rates gpm Fill flow to brine tank Brining Brine Rinse Backwash Fast Rinse GXSS17Z 31 2 6 8 x 40 8 50 3 20 125 15 120 3 3 19 12 1 8 1 8 See rating decal located on the Softener Determined by water analysis from a qualifi...

Страница 12: ...heater will fill with the hard water Fill Backwash Salt dissolved in water is called brine Brine is needed to clean the hard minerals from resin beads To make the brine water flows into the salt storage area during the fill stage as shown Brining During brining brine travels from the salt storage area into the resin tank Brine is the cleaning agent needed to remove hard minerals from the resin bea...

Страница 13: ... but the bridge is under it The following is the best way to check for a salt bridge Salt should be loose all the way to the bottom of the tank Take a broom handle or like tool and carefully push it down into the salt working it up and down If the tool strikes a hard object be sure it s not the bottom or sides of the tank it s most likely a salt bridge Carefully break the bridge with the tool Do n...

Страница 14: ...ri Then while holding the nozzle and venturi housing with one hand remove the cap Lift out the screen support and screen then the nozzle and venturi Wash and rinse the parts in warm water until clean If needed use a small brush to remove iron or dirt Also check and clean the gasket NOTE Some models have a small flow plug located in the nozzle and venturi and or a small cone shaped screen in the ho...

Страница 15: ...egin to run out of soft water If the softener is not scheduled to regenerate for another day or two you would get hard water until then If this happens or you think it might happen press and hold in the TOUCH HOLD button for three seconds until RCHG shows RCHG will flash in the display during the regeneration which lasts under two hours NOTE Avoid using HOT water while the softener regenerates bec...

Страница 16: ...en choosing a regeneration starting time other than 2 00 AM Step 2 Press the SET CLEAR button until the desired regeneration starting time shows in the display NOTE Press SET CLEAR and quickly release to move the display ahead 1 hour at a time Or hold the SET CLEAR button to move display ahead 2 hours each second Step 3 Press the REGENERATION DAY button and SUnday begins to flash If you do want re...

Страница 17: ...min M T TH S 3 min M T TH F S SU 3 min Every Day 3 min Every Day 4 min Every Day 4 min M 3 min M TH 3 min M W S 3 min M T TH S 3 min M T TH F S 3 min M T TH F S SU 3 min Every Day 3 min Every Day 4 min Every Day 5 min Every Day 7 min M 4 min M W S 2 min M W S 3 min M T TH F S SU 2 min M T TH F S SU 3 min Every Day 3 min Every Day 4 min Every Day 5 min Every Day 8 min M 5 min M W S 3 min M T TH S 3...

Страница 18: ...ion See the About the Face Plate Timer section Manual bypass valve s in Move stem in single bypass valve to SERVICE bypass position Salt in storage tank bridged See the Breaking a Salt Bridge section Dirty plugged or damaged Take apart and clean or replace damaged parts nozzle venturi See Cleaning the Nozzle and Venturi Assembly section Valve drain hose plugged Hose must not have kinks sharp bends...

Страница 19: ... protection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher washer and dryer range TV VCR and much more any brand Plus there s no extra charge for emergency service and low monthly financing is available Even icemaker coverage and food spoilage protection is offered You can rest easy knowing that al...

Страница 20: ...stment Complete and mail your Consumer Product Ownership Registration today Have the peace of mind of knowing we can contact you in the unlikely event of a safety modification After mailing the registration below store this document in a safe place It contains information you will need should you require service Our service number is 800 GE CARES 800 452 2737 Read your Owner s Manual carefully It ...

Страница 21: ...Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions 21 Parts list ...

Страница 22: ...RE 1 0015 WS06X10003 POWER CORD 1 0016 WS26X10001 TRANSFORMER 1 0017 WS31X10010 COVER SALT HOLE 1 0018 WS33X10001 SEAL VAPOR BARRIER 1 0019 WS33X10002 RIM 1 WS31X10003 COVER BRINEWELL 1 0021 WS02X10009 WING NUT 1 4 20 1 0022 WS32X10002 TANK BRINEWELL ROUND 1 0023 WS02X10011 SCREW 1 4 20 NYLON 1 0024 WS32X10003 TANK BRINE ROUND 1 0025 WS18X10003 CLAMPHOSE 1 0026 WS22X10016 ADAPTER HOSE 1 0027 WS22X...

Страница 23: ...Parts list Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions 23 ...

Страница 24: ... VENT 1 0115 WS03X10015 CONE SCREEN 1 0116 WS22X10021 PLUG FILL FLOW 3 GPM 1 0117 WS03X10017 NUT FERRULE 1 0118 WS15X10009 NOZZLE VENTURI ASM 1 0119 WS03X10018 RETAINER 1 0120 WS03X10019 SEAL O RING 1 4 X 3 8 2 0121 WS15X10010 BODY VALVE 1 0122 WS03X10020 SPRING 1 0123 WS22X10022 PLUG DRAIN SALT 1 0130 WS35X10005 SEAL KIT 1 0132 WS22X10023 ADAPTER DRAIN HOSE 1 0133 WS03X10021 O RING 5 8 X 13 16 1 ...

Страница 25: ...Notes Customer Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions 25 ...

Страница 26: ...er Service Troubleshooting Tips Installation Instructions Safety Instructions Operating Instructions Customer Service Troubleshooting Tips Safety Instructions Customer Service Troubleshooting Tips Safety Instructions ...

Страница 27: ...do not allow the exclusion or limitation of incidental or consequential damages This warranty gives you specific legal rights and you may also have other rights which vary from state to state To know what your legal rights are consult your local or state consumer affairs office or your state s Attorney General Warrantor General Electric Company Louisville KY 40225 For The Period Of GE Will Replace...

Страница 28: ...irectly to their homes VISA MasterCard and Discover cards are accepted Instructions contained in this manual cover procedures to be performed by any user Other servicing generally should be referred to qualified service personnel Caution must be exercised since improper servicing may cause unsafe operation Service Satisfaction If you are not satisfied with the service you receive from GE First con...

Отзывы: