Chemical Burn Hazard:

■ Keep batteries away from children.  This product contains a lithium button cell battery.  If a new or used lithium

button cell battery is swallowed or enters the body, it can cause severe internal burns and can lead to death in

as little as 2 hours. If you think batteries might have been swallowed or placed inside any part of the body, seek

immediate medical attention.  Always completely secure the battery compartment.  If the battery compartment

does not close securely, stop using the product, remove the battery and keep it away from children.  Properly

dispose of used batteries, keeping them away from children.

To reduce the risk associated with the ingestion of contaminants:

■ 

Do not

use with water that is microbiologically unsafe or of unknown quality without adequate disinfection

before or after the system.  Systems certified for cyst reduction may be used on disinfected water that may

contain filterable cysts.

To reduce the risk associated with choking:

■ 

Do not

allow children under 3 years of age to have access to small parts during the installation of this product.

3

READ AND SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INFORMATION

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE

SA

FE

TY

 IN

FO

RM

AT

IO

N

Read, understand, and follow all safety information contained in these instructions prior to installation and use of the

GE Appliances Reverse Osmosis system.  Retain these instructions for future reference.

Intended use:

The GE Appliances Reverse Osmosis system is intended for use in filtering potable water in Residential applications,

and has not been evaluated for other uses.  The system is typically installed at the point of use, and must be installed

as specified in the installation instructions.  Contact a plumbing professional if you are uncertain how to install.

SAFETY PRECAUTIONS

Be sure the water supply conforms with the Specification Guidelines.  If the water supply conditions are unknown,

contact your municipal water company or your local health department for a list of contaminants in your area and a

list of laboratories certified by your state to analyze drinking water.

WARNING

WARNING

To reduce the risk of physical injury due to hydropneumatic tank rupture:

■ 

Do not

install if water pressure exceeds 100 psi (689 kPa).  If your water pressure exceeds 80 psi (552 kPa),

you should install a pressure limiting valve.  Contact a plumbing professional if you are uncertain how to check

your water pressure.

■ 

Do not

install where water hammer conditions may occur.  If water hammer conditions exist you should install

a water hammer arrester.  Contact a plumbing professional if you are uncertain how to check for this condition.

■ Where a backflow prevention device is installed on a water system, a device for controlling pressure due to

thermal expansion should be installed.

WARNING

To reduce the risk associated with ingesting of water contaminated with sanitizer:

■ After installation, sanitizer MUST be flushed from the system before first use as directed within the installation

instructions.

This system has been tested for the treatment of water containing pentavalent arsenic (also known as As(V), As(+5)

or arsenate) at concentrations of 0.050 mg/L or less.  This system reduces pentavalent arsenic, but may not remove

other forms of arsenic.  This system is to be used on water supplies containing a detectable free chlorine residual or

on water supplies that have been demonstrated to contain only pentavalent arsenic.  Treatment with chloramine

(combined chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic.

Please see the Arsenic Facts section on page 9 for further information.

The compounds certified under NSF/ANSI 401 have been deemed as “incidental contaminants / emerging

compounds”.  Incidental contaminants are those compounds that have been detected in drinking water supplies at

trace levels.  While occurring at only trace levels, these compounds can affect the public acceptance / perception of

drinking water quality.

WARNING

Содержание GXRV40TBN

Страница 1: ...14 Feed Water Supply 15 Drain Adapter 16 Storage Tank and Faucet 18 Faucet Electronics 19 Remineralization Antimicrobial Filter Bracket 19 Connect Tubes 20 Sanitize the System 22 Test and Purge the Sy...

Страница 2: ...ng other things registration of your appliance ensures that we can deliver important product information and warranty details when you need them Register your GE appliance now online Helpful websites...

Страница 3: ...conditions are unknown contact your municipal water company or your local health department for a list of contaminants in your area and a list of laboratories certified by your state to analyze drink...

Страница 4: ...tem when installed and full of water Ensure all tubing and fittings are secure and free of leaks Do not install unit if any collets parts 14 and 15 on page 29 are missing Contact 800 952 5039 US if co...

Страница 5: ...pt to use this product to make safe drinking water from non potable water sources Do not use the system on microbiologically unsafe water or water of unknown quality without an adequate disinfection b...

Страница 6: ...0 07 g L 97 4 Pass NSF ANSI Standard 58 Influent Challenge Concentration Maximum Permissible Concentration Overall Reduction Results Asbestos 107 to 108 fibers L 99 reduction 99 9 Pass Arsenic pentava...

Страница 7: ...tion Alachlor 2 0 g L 50 g L 1 0 g L 98 Atrazine 3 0 g L 100 g L 3 0 g L 97 Benzene 5 0 g L 81 g L 1 0 g L 99 Carbofuran 40 g L 190 g L 1 0 g L 99 Carbon Tetrachloride 5 0 g L 78 g L 1 8 g L 98 Chloro...

Страница 8: ...ed as N and is certified for nitrate nitrite reduction only for water supplies with a pressure of 40 psig 276 kPa or greater Filter Performance Data Flow Rate 0 8 gallons per minute 3 03 liters per mi...

Страница 9: ...alent arsenic from water These models will not convert trivalent arsenic to pentavalent arsenic If you have free chlorine residual in contact with your water supply for at least one minute any trivale...

Страница 10: ...eeded When the tank is empty of water the pressure at the air valve is 5 7 psi Postfilter After leaving the storage tank but before going to the system faucet product water goes to the post filter car...

Страница 11: ...ows to the drain 6 Faucet is activated 7 Processed water leaves the storage tank and flows to the postfilter where it is filtered to ensure fresh taste 8 Processed water enters the remineralization an...

Страница 12: ...TANT Save these instructions for local inspector s use IMPORTANT Observe all governing codes and ordinances Note to Installer Be sure to leave these instructions with the consumer Note to Consumer Kee...

Страница 13: ...uct water faucet installs on the sink or on the countertop next to the sink It may be installed in an existing sink spray attachment hole or a hole may be drilled Space is required underneath for tubi...

Страница 14: ...ide PLAN THE INSTALLATION The Reverse Osmosis System can be installed under a sink or in a remote location Typical remote sites are a laundry room or utility room Review the location options below and...

Страница 15: ...ortion of the water supply fitting and hand tighten Be careful not to cross thread or overtighten FEED WATER SUPPLY Check and comply with local plumbing codes as you plan then install a cold water sup...

Страница 16: ...drain tube from the RO system directly to an open drain This is often used for remote location installations NOTE An incorrectly connected drain point can cause water to leak from the faucet s air gap...

Страница 17: ...2 air gap between the end of the hose and the drain point This will prevent water from backing up into the system NOTE Check your local plumbing codes To install a remote drain point complete the fol...

Страница 18: ...nipple at the top of the tank 2 Locate the included tank connector Slowly tighten the tank connector onto the tank nipple 7 8 full turns so as not to cross thread or overtighten 3 Do not connect the t...

Страница 19: ...prefilter and postfilter cartridges must be changed Always change the battery as shown on page 25 when replacing the prefilter postfilter cartridges every 6 months FAUCET ELECTRONICS REMINERALIZATION...

Страница 20: ...s INSTALATION INSTRUCTIONS HOW TO CONNECT TUBES Push in Fitting Tube Tube Partially Engaged Collet O Ring Tube Fully Engaged Collet O Ring YELLOW TUBE from Reverse Osmosis assembly to storage tank 1 L...

Страница 21: ...smosis faucet to drain adapter 1 Locate the 3 8 black tube attached to the faucet 2 The loose end needs to be attached to the quick connect fitting on the sink drain adapter 3 Cut this tube as needed...

Страница 22: ...pleted during the pressure test and purging steps on the following page NOTE The bleach must be removed from the system before drinking the water See purging instructions following 22 Installation Ins...

Страница 23: ...and let water flow through the system for a 24 hour period Water flow will be a slow trickle at this time NOTE Do not consume water from the RO system until purging is complete 2 Close the Reverse Os...

Страница 24: ...rse Osmosis membrane cartridge depends mostly on the pH and hardness of the supply water see Specifications Cartridge life is shorter with higher pH For example if supply water pH is from 6 8 to 7 7 t...

Страница 25: ...with the replacement prefilter postfilter cartridge kit Always change the battery as shown below when replacing the prefilter postfilter cartridges every 6 months 1 Locate the battery holder cover on...

Страница 26: ...ecessary to remove the drain port s collet and o ring as shown in the next section to retrieve it ASSEMBLING COLLET AND O RING 1 Remove the collet and o ring from the fitting with a small screwdriver...

Страница 27: ...ir gap to the drain pipe Refer to Installation Instructions for proper drain connection If drain line adapter was used as the drain point periodic inspection cleaning is recommended System makes produ...

Страница 28: ...28 Parts List PARTS LIST GXRV40TBN 1 8 10 14 15 9 7 5 4 3 2 11 12 6 13 22 21 23...

Страница 29: ...WS32X10012 STORAGE TANK 1 0012 WS22X21939 TANK CONNECTOR 1 0013 WS15X21941 FAUCET 1 0014 WS18X21940 DRAIN ADAPTER 1 0015 WS18X21936 WATER SUPPLY FITTING 1 0016 WS35X22001 SANITIZATION KIT OPTIONAL SEE...

Страница 30: ...or acts of God Incidental or consequential damage caused by possible defects with this appliance This warranty is extended to the original purchaser and any succeeding owner for products purchased for...

Страница 31: ..._____________________________ Date _________________ Seller ________________________________________________________________ Date _________________ Seller s Address ___________________________________...

Страница 32: ...rranty and learn about special discounts that are available while your warranty is still in effect You can purchase it online anytime GE Appliances Services will still be there after your warranty exp...