Installation Instructions

EXHAUSTING THE DRYER

- Fire Hazard

WARNING

This dryer MUST be vented to the outdoors.
Use only 4” rigid metal ducting for the home 

exhaust vent.
Use only 4” rigid metal or UL-LISTED transition duct 

to connect the dryer to the home exhaust duct.

DO NOT

 use a plastic vent.

DO NOT

 exhaust into a chimney, kitchen exhaust, 

gas vent, wall, ceiling, attic, crawl space, or 

concealed space of a building.

DO NOT

 install a screen in or over the exhaust duct.

DO NOT

 use duct longer than specified in the 

exhaust length table.
Failure to follow these instructions can result in 

death or fire.

12

CONNECTING THE DRYER TO HOUSE 
VENT

RIGID METAL TRANSITION DUCT

 

For best drying performance, a rigid metal transition 

duct is recommended.

 

Rigid metal transition ducts reduce the risk of crushing 

and kinking.

UL-LISTED FLEXIBLE METAL CLOTHES DRYER  

TRANSITION DUCT

 

 If rigid metal cannot be used, then UL-LISTED flexible 

metal clothes dryer transition duct (GE parts – 

PM08X10085, WX08X10085 or WX08X10077) can be 

used.

 

Never install transition duct in walls, ceilings, floors or 

other enclosed spaces.

 

Total length of transition duct should not exceed 

8’ (2.4 m).

 

For many applications, installing elbows at both 

the dryer and the wall is highly recommended (see 

illustrations at right). Elbows allow the dryer to sit 

close to the wall without kinking and/or crushing the 

transition duct, maximizing drying performance.

 

Avoid resting the duct on sharp objects.

UL-LISTED FLEXIBLE METAL (FOIL-TYPE) TRANSITION 

DUCT

 

In special installations, it may be necessary to connect 

the dryer to the home exhaust vent using flexible metal 

(foil-type) transition duct. UL–LISTED universal flexible 

dryer transition duct (GE parts – PM8X73 or WX8X73) 

may be used ONLY in installations where rigid metal or 

flexible metal transition ducting cannot be used AND 

where a 4” diameter can be maintained throughout 

the entire length of the transition duct.

  In Canada and the United States, only transition ducts that 

comply with “

UL 2158A STANDARD FOR CLOTHES DRYER 

TRANSITION DUCT

” shall be used

.

 

Avoid resting the duct on sharp objects.

 

For best drying performance:

 

1.  Slide one end of the duct over the clothes dryer 

outlet pipe.

 

2.  Secure the duct with a clamp.

 

3.  With the dryer in its permanent position, extend 

the duct to its full length. Allow 2” of duct to 

overlap the exhaust pipe. Cut off and remove 

excess duct. Keep the duct as straight as 

possible for maximum airflow.

 

4.  Secure the duct to the exhaust pipe with the 

other clamp.

TOOLS AND MATERIALS YOU WILL 
NEED TO INSTALL EXHAUST DUCT

PARTS AVAILABLE FROM LOCAL 

SERVICE ORGANIZATIONS

•  Rigid Metal Duct Components

WX8X63 

4 x 1 Duct

WX8X64 

4 x 2 Duct

WX8X51 

4 Elbow

WX8X59 

4 Aluminum Hood

•  Flexible Metal Duct Components

WX8X58 

4 Clamps (2)

WX8X59 

4 Aluminum Hood

 

WX08X10077 

6 UL-Listed, Flexible Metal (Semi-Rigid)  

   

 

  Duct, 2 Clamps, 2 Close Elbows

WE1M454 

Cover rear exhaust opening

ˆ

 

Phillips-head 

screwdriver

ˆ

 

Duct tape or 

duct clamp

ˆ

 

Rigid or UL-listed 

flexible metal 4” 

(10.2 cm) duct

ˆ

 

Drill with 1/8” drill bit 

(for bottom venting)

ˆ

 

Hacksaw

ˆ

 

Vent hood

Содержание GTX42GASJWW

Страница 1: ...dryer installation must be performed by a qualified installer Install the clothes dryer according to these instructions and local codes DO NOT install a clothes dryer with flexible plastic venting ma...

Страница 2: ...056 Dryer door opening vent brush not included WX14X10007 LintEater Dryer rotary tube brush not included 2 ROUGH IN DIMENSIONS State of California Proposition 65 Warnings The California Safe Drinking...

Страница 3: ...or test gauge connection must be installed immediately upstream of the gas supply connection to the dryer POWER CORDS GE strongly recommends the use of factory specified parts Select the power cord to...

Страница 4: ...the rubber flat washer is in place and attach the dryer s long inlet hose to one male end of the Y connector Tighten by hand until firmly seated 6 Ensure the rubber flat washer is in place and attach...

Страница 5: ...FF position Disconnect and discard old flexible gas connector and ducting material Shut off Valve MATERIALS YOU WILL NEED 10 Adjustable wrenches 2 8 Pipe wrench Flat blade screwdriver Level Slip joint...

Страница 6: ...ed 3 feet ADJUSTING FOR ELEVATION Gas clothes dryers input ratings are based on sea level operation and need not be adjusted for operation at or below 2000 ft elevation For operation at elevations abo...

Страница 7: ...SUPPLY cont Open the gas shut off valve F Apply pipe compound or PTFE tape to all male threads Shut Off Valve Plugged Tapping CONNECTING THE DRYER TO THE GAS SUPPLY Install a female 3 8 NPT elbow at t...

Страница 8: ...NFPA 70 or Canadian Electrical Code CSA C22 1 This appliance must be supplied with 120V 60Hz and be connected to a properly grounded branch circuit protected by a 15 or 20 amp circuit breaker or time...

Страница 9: ...OFF THE TERMINAL BLOCK Slip joint pliers Flat blade crewdriver Phillips screwdriver Level TOOLS YOU WILL NEED MATERIALS YOU WILL NEED 4 dia metal elbow 3 4 strain relief UL recognized 4 duct clamps 2...

Страница 10: ...lure to do so can result in death fire or electrical shock GROUNDING INSTRUCTIONS For a grounded cord connected dryer This dryer must be grounded In the event of a malfunction or breakdown grounding w...

Страница 11: ...e electrical box 2 Be sure the dryer cord is unplugged from the wall receptacle 3 Remove the power cord cover located at the lower back 4 Remove and discard ground strap Keep the green ground screw fo...

Страница 12: ...duct on sharp objects UL LISTED FLEXIBLE METAL FOIL TYPE TRANSITION DUCT In special installations it may be necessary to connect the dryer to the home exhaust vent using flexible metal foil type trans...

Страница 13: ...ill be treated like one 90 elbow For every additional 90 elbow reduce the allowable vent system length by 10 feet When calculating the total vent system length you must add all the straight portions a...

Страница 14: ...nce to the exhaust airflow and should require little or no maintenance to prevent clogging Wall caps must be installed at least 12 above ground level or any other obstruction with the opening pointed...

Страница 15: ...tab on the appliance base ADDING ELBOW AND DUCT FOR EXHAUST TO SIDE OF CABINET TAB LOCATION Fire Hazard WARNING Close the back opening with cover plate Kit WE1M454 Disconnect dryer from electrical su...

Страница 16: ...BOTTOM OF CABINET Insert the elbow through the rear opening and connect it to the dryer internal duct Apply duct tape as shown on the joint between the dryer internal duct and the elbow and also the...

Страница 17: ...ped putty knife Small flat blade screwdriver Before you start Unplug the dryer from its electrical outlet Choose the REVERSING THE DOOR instructions A or B for your model A REVERSING THE DOOR SOLID DO...

Страница 18: ...er left side screw holes and firmly tighten all 4 screws 6 Install the 4 plastic caps removed in step 1 into the 4 right side front panel holes NOTE To return the door to the original setup follow the...

Страница 19: ...oles 2 on the left and 2 on the right 3 Loosen each top hinge screw on right side Remove the door and place it on a protective flat surface to avoid any damage Plastic Cap 4 Left side of front panel L...

Страница 20: ...r back into its electrical outlet Door Hang door and tighten screws B REVERSING THE DOOR GLASS PANEL DOOR MODELS cont 6 Remove and swap the 2 plastic caps and the 2 hinges 7 Rotate the outer door 180...

Страница 21: ...nstalaci n de la secadora debe efectuarla un instalador calificado Instale la secadora de ropa de acuerdo con estas instrucciones y en cumplimiento con los c digos locales NO instale una secadora de r...

Страница 22: ...Potable Inocua y Tratamiento de Residuos T xicos de California California Safe Drinking Water and Toxic Enforcement Act solicita al Gobernador de California que publique una lista de sustancias que e...

Страница 23: ...en la parte trasera pero 1 2 54 cm m nimo es la recomendada El espacio vertical m nimo de la parte superior de la secadorahastalosestantes armarios techos etc esde1 Se deber considerar que se debe br...

Страница 24: ...en su lugar y sujete la manguera larga de entrada de la secadora a un extremo macho del conector en Y Ajuste a mano hasta que est firmemente asentada 6 Aseg rese de que la arandela plana de goma se e...

Страница 25: ...exible de gas y el material del conducto V lvula de cierre HERRAMIENTAS NECESARIAS MATERIALES NECESARIOS Llaves ajustables de 10 2 Llave para tubos de 8 Destornillador de lados planos Nivel Pinzas Cod...

Страница 26: ...ncionar en o por debajo de los 2000 pies de elevaci n Para un funcionamiento a m s de 2000 pies de elevaci n los niveles de entrada se deber an reducir a un promedio del 4 por ciento por cada 1000 pie...

Страница 27: ...compuesto para tuber a o cinta PTFE en todas las roscas macho V lvula de apagado Toma a rosca C MO CONECTAR LA SECADORA AL SUMINISTRO DE GAS Instale un codo hembra NPT de 3 8 al final de la entrada de...

Страница 28: ...erra adecuada antes del uso Nunca utilice una llama abierta para detectar p rdidas de gas Controle todas las conexiones con una soluci n jabonosa o un elemento equivalente Aplique una soluci n jabonos...

Страница 29: ...el tomacorriente de la vivienda antes de comprar el cable 4 Placa de cubierta Kit WE1M454 C MO CONECTAR UNA SECADORA ELECTRICA S ltese si se trata de las secadoras a gas o si su secadora ya tiene un...

Страница 30: ...producir la muerte incendio o descarga el ctrica INSTRUCCIONES DE CONEXI N A TIERRA Para una secadora conectada con cable con conexi n a tierra Esta secadora deber estar conectado a tierra En caso de...

Страница 31: ...sible del circuito de la secadora de la caja el ctrica 2 Verifique que el cable de la secadora est desenchufado del tomacorriente 3 Quite la tapa del cable de energ a ubicada en la parte trasera infer...

Страница 32: ...uber a se apoye sobre objetos cortantes CONDUCTO DE TRANSICI N DE METAL FLEXIBLE TIPO HOJA DE ALUMINIO DE LA LISTA DE UL En instalaciones especiales puede ser necesario conectar la secadora a la venti...

Страница 33: ...codos de 45 deber n ser considerados como un codo de 90 Para cada codo adicional de 90 reduzca en 10 pies la longitud permisible del sistema de escape En el c lculo de la longitud total del sistema de...

Страница 34: ...be requerir poco mantenimiento para evitar las obstrucciones Las cubiertas de pared deben instalarse por lo menos a 12 sobre el nivel del suelo o cualquier otra obstrucci n con la abertura apuntando h...

Страница 35: ...r a trav s de la leng eta de la base del artefacto C MO AGREGAR CODOS Y CONDUCTOS DE SALIDA HACIA DEL GABINETE Corte el conducto como puede verse y conserve la porci n A Para los modelos GTD60 GTD65 y...

Страница 36: ...cto interno de la secadora Aplique cinta aislante como puede verse en la junta entre el conducto interno de la secadora y el codo y tambi n en la junta entre el codo y el conducto inferior Las juntas...

Страница 37: ...stornillador de punta plana peque a Antes de Comenzar Desenchufe la secadora del tomacorriente A INVERSI N DE LA PUERTA MODELOS DE PUERTA S LIDA 1 Abra la puerta aproximadamente 130 grados Con una esp...

Страница 38: ...izquierdo y apriete firmemente los cuatro tornillos 6 Instale las cuatro tapas de pl stico retiradas en el paso 1 en los 4 agujeros del panel frontal derecho NOTA Para regresar la puerta a la configu...

Страница 39: ...opuestas Tapa de pl stico 4 Lado izquierdo del panel frontal Placa ciega Placa de refuerzo 3 Afloje cada tornillo de la bisagra superior en el lado derecho Retire la puerta y coloque la misma sobre un...

Страница 40: ...a enchufar la secadora en la salida el ctrica Puerta Sostenga la puerta y ajuste los tornillos Tapa de pl stico 4 Lado derecho del panel frontal B INVERSI N DE LA PUERTA MODELOS CON PANEL DE CRISTAL...

Отзывы: