background image

Installation Instructions

SIDE OR BOTTOM VENTING

Disconnect dryer from electrical supply.
Wear gloves and arm guards.
Close the back opening with cover plate (Kit 

WE49X22606).
Failure to do so may result in fire, electrical 

shock or lacerations.

WARNING

Fire Hazard

- Fire Hazard

WARNING

15

SIDE OR BOTTOM VENTING (cont.)

Dryer Exhaust to right of the cabinet for Electric 

models only.
Dryer Exhaust to left of the cabinet for Gas and 

Electric models.
Dryer Exhaust to the bottom of cabinet for Gas 

and Electric models.

Detach and remove the right (electric models only), 

left or bottom knockout as desired. Remove the 

screw inside the dryer exhaust duct and save.  

Pull the duct out of the dryer.
Cut the duct as shown and keep portion A.

ADDING A NEW DUCT

Reconnect the cut portion (A) of the duct to the blower 

housing. Make sure that the shortened duct is aligned 

with the tab in the base. Use the screw saved previously 

to secure the duct in place through the tab on the 

appliance base.

ADDING ELBOW AND DUCT FOR 

EXHAUST TO RIGHT (ELECTRIC 

MODELS ONLY) OR LEFT SIDE OF 

CABINET

•   Preassemble 4” elbow with 4” duct. Wrap duct tape 

around joint.

•  Insert duct assembly, elbow first, through the side 

opening and connect the elbow to the dryer internal 

duct.

Be sure not to pull or damage the electrical 

wires inside the dryer when inserting the duct.

TAB LOCATION

Remove 

screw 

and save

Remove desired 

knockout (one only)

Right 

(electric 

models 

only)

Left

Bottom

Through the rear opening, locate the tab in the middle 

of the appliance base. Lift the tab to about 45°,

 

using 

a flat-blade screwdriver.

Portion “A”

Right (electric 

models only) 

or left side 

exhaust

Fixing hole

Left

Right

Exhaust can be 

added to right 

(electric models 

only) or left side

Duct 

tape

Right

Left

Bend tab  

up 45°

Not for gas models

Left

EXHAUSTING THE DRYER (cont.)

Fixing hole

A

10 

1

2

” (26.67cm)

For 7.4 cu. ft. models only,

 use the dimension 

below:

Fixing hole

A

1

2

” (24.13cm)

For 6.2 and 7.2 cu. ft. models only,

 use the dimension 

below:

Содержание GTD84GCSNWS

Страница 1: ...t not exceed 4 feet FOR GAS DRYERS ONLY BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTANT Save these instructions for local electrical inspector s use IMPORTANT Observe all g...

Страница 2: ...Order on line at GEApplianceparts com 24 hours a day or by phone at 877 959 8688 during normal business hours STEAM WATER HOSES for steam dryer models only ACCESSORIES Order on line at GEAppliancepart...

Страница 3: ...he floor for a garage installation Failure to do so can result in death explosion or fire The dryer MUST be vented to the outdoors Minimum clearance between dryer cabinet and adjacent walls or other s...

Страница 4: ...n at the same time NOTE Use new inlet hoses never use old hoses 1 Turn the cold water faucet off Remove the washer inlet hose from the washer fill valve connector cold 2 Ensure the rubber flat washer...

Страница 5: ...discard old flexible gas connector and ducting material Shut off Valve MATERIALS YOU WILL NEED 4 dia metal elbow Pipe compound or PTFE tape Flexible gas line connector Duct clamps 2 or Spring clamps...

Страница 6: ...not exceed 4 feet Use a new CSA International approved flexible gas supply line Never reuse old flexible connectors Install an individual manual shut off valve within 6ft of the dryer in accordance w...

Страница 7: ...ER TO THE GAS SUPPLY cont Open the gas shut off valve F Apply pipe compound or PTFE tape to all male threads Shut Off Valve Plugged Tapping CONNECTING THE DRYER TO THE GAS SUPPLY Install a female 3 8...

Страница 8: ...down grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This dryer uses a cord having an equipment grounding conductor and a grounding plug T...

Страница 9: ...ILL NEED Slip joint pliers Level 4 dia UL listed flexible metal duct if needed Dryer power cord kit not provided with dryer UL rated 120 240V 30A with 3 or 4 prongs Identify the plug type as per the h...

Страница 10: ...his dryer must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This dryer uses a co...

Страница 11: ...EAVE THE COVER OFF OF THE TERMINAL BLOCK NEVER LEAVE THE COVER OFF OF THE TERMINAL BLOCK 1 Turn off the circuit breaker s 30 amp or remove the dryer s circuit fuse at the electrical box 2 Be sure the...

Страница 12: ...ada and the United States only transition ducts that comply with UL 2158A STANDARD FOR CLOTHES DRYER TRANSITION DUCT shall be used Avoid resting the duct on sharp objects For best drying performance 1...

Страница 13: ...45 elbows will be treated like one 90 elbow For the side exhaust installations add one 90 elbow to the chart For every additional 90 elbow reduce the allowable vent system length by 10 feet When calcu...

Страница 14: ...rflow and should require little or no maintenance to prevent clogging Wall caps must be installed at least 12 above ground level or any other obstruction with the opening pointed down SEPARATION OF TU...

Страница 15: ...e screw saved previously to secure the duct in place through the tab on the appliance base ADDING ELBOW AND DUCT FOR EXHAUST TO RIGHT ELECTRIC MODELS ONLY OR LEFT SIDE OF CABINET Preassemble 4 elbow w...

Страница 16: ...up before pressing Power Otherwise the display will not come on The dryer is now ready for use 3 Connect standard metal elbows and ducts to complete the exhaust system Cover back opening with the plat...

Страница 17: ...ewdriver n Tape tipped putty knife n Small flat blade screwdriver Before you start Unplug the dryer from its electrical outlet Choose the REVERSING THE DOOR instructions A or B for your model A REVERS...

Страница 18: ...d in step 3 into the lower left side screw holes and firmly tighten all 4 screws 6 Install the 4 plastic caps removed in step 1 into the 4 right side front panel holes NOTE To return the door to the o...

Страница 19: ...oles 2 on the left and 2 on the right 3 Loosen each top hinge screw on right side Remove the door and place it on a protective flat surface to avoid any damage Plastic Cap 4 Left side of front panel L...

Страница 20: ...you finish Plug the dryer back into its electrical outlet Door Hang door and tighten screws B REVERSING THE DOOR GLASS PANEL DOOR MODELS cont 6 Remove and swap the 2 plastic caps and the 2 hinges 7 Ro...

Страница 21: ...A GAS NICAMENTE ANTES DE COMENZAR Lea estas instrucciones por completo y con detenimiento IMPORTANTE Guarde estas instrucciones para el uso de inspectores el ctricos locales IMPORTANTE Cumpla con tod...

Страница 22: ...t Manguera corta adaptador en Y arandelas y WE1M847 Manguera Larga O POR SEPARADO WE1M847 Manguera Larga y WE1M848 Manguera Corta Instrucciones de instalaci n Incline la secadora de costado y saque lo...

Страница 23: ...r una explosi n incendio o la muerte Esta secadora DEBE tener una ventilaci n al exterior El espacio libre m nimo entre el armario de la secadora y las paredes adyacentes u otras superficies es 0 sobr...

Страница 24: ...sta que est firmemente asentada 5 Aseg rese de que la arandela de goma plana se encuentra en su posici n y coloque una manguera de entrada de agua de 4 a 6 pies de largo puede ser necesario comprarla...

Страница 25: ...as y el material del conducto V lvula de cierre MATERIALES NECESARIOS Codo de metal de 4 di metro Compuesto o PTFE cinta para tuber as Conector de tuber a de gas flexible Abrazaderas de tuber a 2 o ab...

Страница 26: ...da por CSA International Nunca vuelva a usar conectores flexibles viejos Instale una v lvula de cierre manual individual dentro de 6 pies de la secadora en acuerdo con el C digo Nacional de Gas Combus...

Страница 27: ...do del gas F Aplique compuesto para tuber a o cinta PTFE en todas las roscas macho V lvula de apagado Toma a rosca C MO CONECTAR LA SECADORA AL SUMINISTRO DE GAS Instale un codo hembra NPT de 3 8 al f...

Страница 28: ...ecadora est instalada en su posici n final Si el circuito tiene un recept culo de 2 clavijas es responsabilidad del propietario de reemplazarlo con un recept culo de 3 clavijas debidamente conectado a...

Страница 29: ...IAS Pinzas Nivel Conducto de metal flexible de 4 de di metro si fuese necesario Kit de cable de energ a de la secadora no incluido con la la secadora Clasificado UL de 120 240V 30A con 3 o 4 patas Ide...

Страница 30: ...onectado a tierra En caso de mal funcionamiento o aver a la conexi n a tierra reducir el riesgo de descargas el ctricas al brindar un camino con una resistencia menor para la corriente el ctrica Este...

Страница 31: ...trav s del alivio de tensi n 5 Conecte el cable de energ a de la siguiente manera A Conecte los dos cables vivos a los tornillos externos del bloque terminal marcado L1 y L2 B Conecte el cable neutra...

Страница 32: ...dan aplastar o doblar CONDUCTO DE TRANSICI N DE METAL FLEXIBLE SECADORA DE ROPA DE LA LISTA DE UL Si un conducto de metal r gido no puede ser utilizado entonces un conducto de metal flexible aprobado...

Страница 33: ...ser considerados como un codo de 90 Para el escape lateral agregue un codo de 90 a la tabla Para cada codo adicional de 90 reduzca en 10 pies la longitud permisible del sistema de escape En el c lculo...

Страница 34: ...obstrucci n con la abertura apuntando hacia abajo SEPARACI N DE CURVAS Para un mejor desempe o separe todas las curvas con 4 pies de conducto recto como m nimo incluyendo la distancia entre la ltima...

Страница 35: ...echa s lo modelos a el ctrico Izquierda Parte inferior Vuelva a conectar la porci n cortada A del conducto a la caja del ventilador Aseg rese de que el conducto m s corto se encuentre alineado con la...

Страница 36: ...A A TRAV S DE LA PARTE INFERIOR DEL GABINETE NIVELE LA SECADORA ENCHUFE LA SECADORA 1 CONFIGURACI N FINAL 2 INICIO DE LA SECADORA Presione el bot n Power Encendido NOTA Si la secadora ha sido expuesta...

Страница 37: ...nta cubierta con cinta n Destornillador de punta plana peque a Antes de Comenzar Desenchufe la secadora del tomacorriente A INVERSI N DE LA PUERTA MODELOS DE PUERTA S LIDA 1 Abra la puerta aproximadam...

Страница 38: ...agujeros inferiores del lado izquierdo y apriete firmemente los cuatro tornillos 6 Instale las cuatro tapas de pl stico retiradas en el paso 1 en los 4 agujeros del panel frontal derecho NOTA Para reg...

Страница 39: ...s mismas en posiciones opuestas Tapa de pl stico 4 Lado izquierdo del panel frontal Placa ciega Placa de refuerzo 3 Afloje cada tornillo de la bisagra superior en el lado derecho Retire la puerta y co...

Страница 40: ...a enchufar la secadora en la salida el ctrica Puerta Sostenga la puerta y ajuste los tornillos Tapa de pl stico 4 Lado derecho del panel frontal B INVERSI N DE LA PUERTA MODELOS CON PANEL DE CRISTAL...

Отзывы: