Installation Instructions

3

MOBILE OR MANUFACTURED 

HOME INSTALLATION

•  Installation MUST conform to the 

MANUFACTURED HOME CONSTRUCTION 
AND SAFETY STANDARD, TITLE 24, PART 
3280 or STANDARD FOR MOBILE HOMES 
CAN/CSA-Z240 MH, or, when such standards 
are not applicable, with AMERICAN NATIONAL 
STANDARD FOR MOBILE HOME, ANSI/NFPA 
NO. 501B.

•  The dryer MUST be vented to the outdoors.
•  The exhaust vent MUST be securely fastened to a 

non-combustible portion of the mobile home.

•  The vent MUST NOT be terminated beneath a 

mobile or manufactured home.

•  The vent duct material MUST BE METAL.
•  KIT 14-D346-33 MUST be used to attach the dryer 

securely to the structure.

•  The vent MUST NOT be connected to any other 

duct, vent or chimney.

• 

DO NOT

 use sheet metal screws or other 

fastening devices which extend into the interior of 
the exhaust vent.

•  Provide an opening with a free area of at least 25 

square inches for introduction of outside air into 
the dryer room.

•  See the sections for electrical connection information. 

REQUIREMENTS FOR ALCOVE OR 

CLOSET INSTALLATION

Keep flammable materials and vapors, such as gasoline, 
away from dryer.
Place dryer at least 18” above the floor for a garage 
installation.
Failure to do so can result in death, explosion, or fire.

•  The dryer MUST be vented to the outdoors. 
•  Minimum clearance between dryer cabinet and 

adjacent walls or other surfaces is:

     

0” either side

*

    1” 

front

    1” 

rear

    1” 

top

 

*

 

For improved performance, a 1/2” clearance is 
suggested on each side.

•  The rear of the dryer should face a wall.
•  Consideration must be given to provide adequate 

clearance for installation and service.

•  Closet doors must be louvered or otherwise 

ventilated and have at least 60 square inches of 
open area. If the closet contains both a washer 
and a dryer, doors must contain a minimum of 120 
square inches of open area.

NOTE:

 WHEN THE EXHAUST DUCT IS LOCATED AT 

THE REAR OF THE DRYER, THE CONFIGURATION 
OF THE DUCTING MAY REQUIRE GREATER 
CLEARANCE.

Gas Dryers Only:

•  No other fuel burning appliance shall be installed in 

the same closet as a gas dryer.

•  The dryer must be disconnected from the gas 

supply piping during pressure testing at pressures 
greater than 1/2 psi (3.5 kPa).

•  A 1/8” NPT minimum plugged tapping, accessible 

for test gauge connection, must be installed 
immediately upstream of the gas supply connection 
to the dryer.

MINIMUM CLEARANCE OTHER 

THAN ALCOVE OR CLOSET 

INSTALLATION

Minimum clearance to combustible surfaces and for 
air opening are: 0” both sides

*

, 1” rear and 1” top.

 

*

 

For improved performance, a 1/2” clearance is 
suggested on each side.

The rear of the dryer should face a wall.
Consideration must be given to provide adequate 
clearance for installation and service.

- Explosion Hazard

WARNING

Содержание GTD72EBPNDG

Страница 1: ...ot exceed 4 feet FOR GAS DRYERS ONLY BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTANT Save these instructions for local electrical inspector s use IMPORTANT Observe all gove...

Страница 2: ...Order on line at GEApplianceparts com 24 hours a day or by phone at 877 959 8688 during normal business hours STEAM WATER HOSES for steam dryer models only ACCESSORIES Order on line at GEAppliancepart...

Страница 3: ...UST be vented to the outdoors Minimum clearance between dryer cabinet and adjacent walls or other surfaces is 0 either side 1 front 1 rear 1 top For improved performance a 1 2 clearance is suggested o...

Страница 4: ...n at the same time NOTE Use new inlet hoses never use old hoses 1 Turn the cold water faucet off Remove the washer inlet hose from the washer fill valve connector cold 2 Ensure the rubber flat washer...

Страница 5: ...discard old flexible gas connector and ducting material Shut off Valve MATERIALS YOU WILL NEED 4 dia metal elbow Pipe compound or PTFE tape Flexible gas line connector Duct clamps 2 or Spring clamps...

Страница 6: ...nect shall not exceed 4 feet Use a new CSA International approved flexible gas supply line Never reuse old flexible connectors Install an individual manual shut off valve within 6ft of the dryer in ac...

Страница 7: ...ER TO THE GAS SUPPLY cont Open the gas shut off valve F Apply pipe compound or PTFE tape to all male threads Shut Off Valve Plugged Tapping CONNECTING THE DRYER TO THE GAS SUPPLY Install a female 3 8...

Страница 8: ...down grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This dryer uses a cord having an equipment grounding conductor and a grounding plug T...

Страница 9: ...ntify the plug type as per the house receptacle before purchasing line cord Flat blade screwdriver Phillips screwdriver 4 Cover Plate Kit WE49X22606 if needed Disconnect power supply before servicing...

Страница 10: ...or electrical shock For electrical connections using a power cord GROUNDING INSTRUCTIONS For a grounded cord connected dryer This dryer must be grounded In the event of a malfunction or breakdown gro...

Страница 11: ...breaker s 30 amp or remove the dryer s circuit fuse at the electrical box 2 Be sure the dryer cord is unplugged from the wall receptacle 3 Remove the power cord cover located at lower back 4 Install...

Страница 12: ...harp objects For best drying performance 1 Slide one end of the duct over the clothes dryer outlet pipe 2 Secure the duct with a clamp 3 With the dryer in its permanent position extend the duct to its...

Страница 13: ...45 elbows will be treated like one 90 elbow For the side exhaust installations add one 90 elbow to the chart For every additional 90 elbow reduce the allowable vent system length by 10 feet When calcu...

Страница 14: ...rflow and should require little or no maintenance to prevent clogging Wall caps must be installed at least 12 above ground level or any other obstruction with the opening pointed down SEPARATION OF TU...

Страница 15: ...ved previously to secure the duct in place through the tab on the appliance base ADDING ELBOW AND DUCT FOR EXHAUST TO RIGHT ELECTRIC MODELS ONLY OR LEFT SIDE OF CABINET Preassemble 4 elbow with 4 duct...

Страница 16: ...up before pressing Power Otherwise the display will not come on The dryer is now ready for use 3 Connect standard metal elbows and ducts to complete the exhaust system Cover back opening with the plat...

Страница 17: ...rewdriver Tape tipped putty knife Small flat blade screwdriver Before you start Unplug the dryer from its electrical outlet Choose the REVERSING THE DOOR instructions A or B for your model A REVERSING...

Страница 18: ...d in step 3 into the lower left side screw holes and firmly tighten all 4 screws 6 Install the 4 plastic caps removed in step 1 into the 4 right side front panel holes NOTE To return the door to the o...

Страница 19: ...oles 2 on the left and 2 on the right 3 Loosen each top hinge screw on right side Remove the door and place it on a protective flat surface to avoid any damage Plastic Cap 4 Left side of front panel L...

Страница 20: ...you finish Plug the dryer back into its electrical outlet Door Hang door and tighten screws B REVERSING THE DOOR GLASS PANEL DOOR MODELS cont 6 Remove and swap the 2 plastic caps and the 2 hinges 7 Ro...

Страница 21: ...GAS NICAMENTE ANTES DE COMENZAR Lea estas instrucciones por completo y con detenimiento IMPORTANTE Guarde estas instrucciones para el uso de inspectores el ctricos locales IMPORTANTE Cumpla con todos...

Страница 22: ...t Manguera corta adaptador en Y arandelas y WE1M847 Manguera Larga O POR SEPARADO WE1M847 Manguera Larga y WE1M848 Manguera Corta Instrucciones de instalaci n Incline la secadora de costado y saque lo...

Страница 23: ...de la secadora y las paredes adyacentes u otras superficies es 0 sobre ambos lados 1 sobre el frente 1 la parte trasera 1 superior Para mejorar el desempe o se sugiere un espacio libre de 1 2 en cada...

Страница 24: ...sta que est firmemente asentada 5 Aseg rese de que la arandela de goma plana se encuentra en su posici n y coloque una manguera de entrada de agua de 4 a 6 pies de largo puede ser necesario comprarla...

Страница 25: ...as y el material del conducto V lvula de cierre MATERIALES NECESARIOS Codo de metal de 4 di metro Compuesto o PTFE cinta para tuber as Conector de tuber a de gas flexible Abrazaderas de tuber a 2 o ab...

Страница 26: ...est aprobada por CSA International Nunca vuelva a usar conectores flexibles viejos Instale una v lvula de cierre manual individual dentro de 6 pies de la secadora en acuerdo con el C digo Nacional de...

Страница 27: ...do del gas F Aplique compuesto para tuber a o cinta PTFE en todas las roscas macho V lvula de apagado Toma a rosca C MO CONECTAR LA SECADORA AL SUMINISTRO DE GAS Instale un codo hembra NPT de 3 8 al f...

Страница 28: ...ecadora est instalada en su posici n final Si el circuito tiene un recept culo de 2 clavijas es responsabilidad del propietario de reemplazarlo con un recept culo de 3 clavijas debidamente conectado a...

Страница 29: ...e enchufe seg n el tomacorriente de la vivienda antes de comprar el cable 4 Placa de cubierta Kit WE49X22606 si fuese necesario Destornillador de lados planos Destornillador Phillips Desconecte el sum...

Страница 30: ...s Consulte a un electricista calificado o personal o representantes del servicio t cnico si tiene dudas de que el electrodom stico se encuentre conectado a tierra apropiadamente NO modifique el enchuf...

Страница 31: ...senchufado del tomacorriente 3 Retire la tapa del cable de corriente ubicada en la parte inferior trasera 4 Instale un alivio de tensi n de 3 4 pulgadas reconocido por UL en el orificio de entrada del...

Страница 32: ...a como en la pared Los codos permiten que la secadora pueda estar junto a la pared sin que se aplaste ni se doble el conducto de transici n maximizando el rendimiento del secado Evite que la tuber a s...

Страница 33: ...ser considerados como un codo de 90 Para el escape lateral agregue un codo de 90 a la tabla Para cada codo adicional de 90 reduzca en 10 pies la longitud permisible del sistema de escape En el c lculo...

Страница 34: ...obstrucci n con la abertura apuntando hacia abajo SEPARACI N DE CURVAS Para un mejor desempe o separe todas las curvas con 4 pies de conducto recto como m nimo incluyendo la distancia entre la ltima...

Страница 35: ...modelos a el ctrico Izquierda Parte inferior Vuelva a conectar la porci n cortada A del conducto a la caja del ventilador Aseg rese de que el conducto m s corto se encuentre alineado con la leng eta d...

Страница 36: ...A A TRAV S DE LA PARTE INFERIOR DEL GABINETE NIVELE LA SECADORA ENCHUFE LA SECADORA 1 CONFIGURACI N FINAL 2 INICIO DE LA SECADORA Presione el bot n Power Encendido NOTA Si la secadora ha sido expuesta...

Страница 37: ...ta cubierta con cinta Destornillador de punta plana peque a Antes de Comenzar Desenchufe la secadora del tomacorriente A INVERSI N DE LA PUERTA MODELOS DE PUERTA S LIDA 1 Abra la puerta aproximadament...

Страница 38: ...agujeros inferiores del lado izquierdo y apriete firmemente los cuatro tornillos 6 Instale las cuatro tapas de pl stico retiradas en el paso 1 en los 4 agujeros del panel frontal derecho NOTA Para reg...

Страница 39: ...s mismas en posiciones opuestas Tapa de pl stico 4 Lado izquierdo del panel frontal Placa ciega Placa de refuerzo 3 Afloje cada tornillo de la bisagra superior en el lado derecho Retire la puerta y co...

Страница 40: ...a enchufar la secadora en la salida el ctrica Puerta Sostenga la puerta y ajuste los tornillos Tapa de pl stico 4 Lado derecho del panel frontal B INVERSI N DE LA PUERTA MODELOS CON PANEL DE CRISTAL...

Отзывы: